Agreement between cardiac output estimation by multi-beat analysis of arterial blood pressure waveforms and continuous thermodilution in post cardiac surgery intensive care unit patients

被引:6
|
作者
Khanna, Ashish K. [1 ,2 ,3 ]
Nosow, Lillian [4 ]
Sands, Lauren [5 ]
Saha, Amit K. [3 ,6 ]
Agashe, Harshavardhan [7 ]
Harris, Lynnette [3 ,6 ]
Martin, R. Shayn [8 ]
Marchant, Bryan [9 ]
机构
[1] Atrium Hlth Wake Forest Baptist Med Ctr, Wake Forest Sch Med, Dept Anesthesiol, Sect Crit Care Med, Winston Salem, NC 27157 USA
[2] Outcomes Res Consortium, Cleveland, OH 44112 USA
[3] Perioperat Outcomes & Informat Collaborat POIC, Winston Salem, NC 27101 USA
[4] Wake Forest Sch Med, Winston Salem, NC 27101 USA
[5] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
[6] Atrium Hlth Wake Forest Baptist Med Ctr, Wake Forest Sch Med, Dept Anesthesiol, Winston Salem, NC USA
[7] Retia Med, Valhalla, NY USA
[8] Atrium Hlth Wake Forest Baptist Med Ctr, Wake Forest Sch Med, Dept Surg, Winston Salem, NC 27157 USA
[9] Atrium Hlth Wake Forest Baptist Med Ctr, Wake Forest Sch Med, Dept Anesthesiol, Sect Crit Care Med,Sect Cardiac Anesthesiol, Winston Salem, NC USA
关键词
Pulse wave analysis; Cardiac output; Hemodynamics; Monitoring; Cardiac surgery; Post-operative; Intensive care unit; METAANALYSIS; STATISTICS;
D O I
10.1007/s10877-022-00924-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We sought to assess agreement of cardiac output estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CTD) and a novel pulse wave analysis (PWA) method that performs an analysis of multiple beats of the arterial blood pressure waveform (CO-MBA) in post-operative cardiac surgery patients. PAC obtained CO-CTD measurements were compared with CO-MBA measurements from the Argos monitor (Retia Medical; Valhalla, NY, USA), in prospectively enrolled adult cardiac surgical intensive care unit patients. Agreement was assessed via Bland-Altman analysis. Subgroup analysis was performed on data segments identified as arrhythmia, or with low CO (less than 5 L/min). 927 hours of monitoring data from 79 patients was analyzed, of which 26 had arrhythmia. Mean CO-CTD was 5.29 +/- 1.14 L/min (bias +/- precision), whereas mean CO-MBA was 5.36 +/- 1.33 L/min, (4.95 +/- 0.80 L/min and 5.04 +/- 1.07 L/min in the arrhythmia subgroup). Mean of differences was 0.04 +/- 1.04 L/min with an error of 38.2%. In the arrhythmia subgroup, mean of differences was 0.14 +/- 0.90 L/min with an error of 35.4%. In the low CO subgroup, mean of differences was 0.26 +/- 0.89 L/min with an error of 40.4%. In adult patients after cardiac surgery, including those with low cardiac output and arrhythmia CO-MBA is not interchangeable with the continuous thermodilution method via a PAC, when using a 30% error threshold.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [21] Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit
    Linton, RA
    Jonas, MM
    Tibby, SM
    Murdoch, IA
    O'Brien, TK
    Linton, NWF
    Band, DM
    INTENSIVE CARE MEDICINE, 2000, 26 (10) : 1507 - 1511
  • [22] Continuous Arterial Pressure Waveform Analysis Accurately Detects Cardiac Output in Cardiac Surgery: A Prospective Comparison with Thermodilution, Echocardiography, and Magnetic Resonance Techniques
    Senay, Sahin
    Toraman, Fevzi
    Gelmez, Serkan
    Dagdelen, Sinan
    Karabulut, Hasan
    Alhan, Cem
    HEART SURGERY FORUM, 2009, 12 (02): : E75 - E78
  • [23] Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
    Karim Kouz
    Frederic Michard
    Alina Bergholz
    Christina Vokuhl
    Luisa Briesenick
    Phillip Hoppe
    Moritz Flick
    Gerhard Schön
    Bernd Saugel
    Critical Care, 25
  • [24] Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
    Kouz, Karim
    Michard, Frederic
    Bergholz, Alina
    Vokuhl, Christina
    Briesenick, Luisa
    Hoppe, Phillip
    Flick, Moritz
    Schon, Gerhard
    Saugel, Bernd
    CRITICAL CARE, 2021, 25 (01)
  • [25] Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit
    Nicolas Langwieser
    Luisa Prechtl
    Agnes S. Meidert
    Alexander Hapfelmeier
    Christian Bradaric
    Tareq Ibrahim
    Karl-Ludwig Laugwitz
    Roland M. Schmid
    Julia Y. Wagner
    Bernd Saugel
    Clinical Research in Cardiology, 2015, 104 : 518 - 524
  • [26] Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit
    Langwieser, Nicolas
    Prechtl, Luisa
    Meidert, Agnes S.
    Hapfelmeier, Alexander
    Bradaric, Christian
    Ibrahim, Tareq
    Laugwitz, Karl-Ludwig
    Schmid, Roland M.
    Wagner, Julia Y.
    Saugel, Bernd
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (06) : 518 - 524
  • [27] COMPARISON BETWEEN ULTRASONIC AND THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS IN INTENSIVE-CARE PATIENTS
    VANDENBOGAERDE, JF
    SCHELDEWAERT, RG
    RIJCKAERT, DL
    CLEMENT, DL
    COLARDYN, FA
    CRITICAL CARE MEDICINE, 1986, 14 (04) : 294 - 297
  • [28] Cardiac Safety of Clonidine and Quetiapine in Post-Cardiac Surgery Intensive Care Unit Patients
    Alshaya, Abdulrahman I.
    Gilmore, James F.
    Nashett, Rebecca M.
    Kovacevic, Mary P.
    Dube, Kevin M.
    Assiri, Ibrahim M.
    Malloy, Rhynn J.
    JOURNAL OF PHARMACY PRACTICE, 2023, 36 (02) : 309 - 314
  • [29] Uncalibrated Radial and Femoral Arterial Pressure Waveform Analysis for Continuous Cardiac Output Measurement: An Evaluation in Cardiac Surgery Patients
    Hofer, Christoph K.
    Button, Danny
    Weibel, Luc
    Genoni, Michele
    Zollinger, Andreas
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (02) : 257 - 264
  • [30] Estimation of cardiac output variations induced by hemodynamic interventions using multi-beat analysis of arterial waveform: a comparative off-line study with transesophageal Doppler method during non-cardiac surgery
    Arthur Le Gall
    Fabrice Vallée
    Jona Joachim
    Alex Hong
    Joaquim Matéo
    Alexandre Mebazaa
    Etienne Gayat
    Journal of Clinical Monitoring and Computing, 2022, 36 : 501 - 510