An Indirect Method for the Estimation of Sodium Vapour Concentration Using an Online Oxygen Sensor

被引:0
|
作者
Kundu, Dipankar [1 ]
Ravindranath, Nair Afijith [1 ,2 ]
Ganesan, Rajesh [1 ,2 ]
Jayaraman, V. [1 ,2 ]
机构
[1] Mat Chem Div, Indira Gandhi Ctr Atom Res, Mat Chem & Met Fuel Cycle Grp, Kalpakkam 603102, Tamilnadu, India
[2] Homi Bhabha Natl Inst, Training Sch Complex, Mumbai 400094, India
关键词
sodium vapour; oxygen sensor; dynamic equilibrium; sodium vapour estimation; molar enthalpy of evaporation; NA-O; AEROSOL; SYSTEMS;
D O I
10.1149/1945-7111/ad2312
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An online method is developed for the estimation of sodium vapour concentration in a confined volume using an oxygen sensor. First, the sodium vapour is made to react with a known amount of oxygen and the change in oxygen concentration in the presence and absence of the sodium vapour are measured using a YSZ-based potentiometric sensor. The sodium vapour concentration in the confined volume is then calculated from the consumed oxygen concentration. This methodology utilizes an indirect way for the estimation of sodium vapour concentration. Indirect estimation of sodium concentration using an online oxygen sensor.Utilizes the reaction between sodium and oxygen to form sodium oxides.The consumption of oxygen is correlated to sodium concentration.Comparison of estimated sodium vapour concentration with literature data.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] A Proposal of Estimation System for Concentration Situation by Using Acceleration Sensor
    Okubo, Masashi
    Fujimura, Aya
    RO-MAN 2009: THE 18TH IEEE INTERNATIONAL SYMPOSIUM ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION, VOLS 1 AND 2, 2009, : 794 - +
  • [12] A Novel Online Parameter Estimation Method for Indirect Field Oriented Induction Motor Drives
    Yang, Shuying
    Ding, Dawei
    Li, Xi
    Xie, Zhen
    Zhang, Xing
    Chang, Liuchen
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (04) : 1562 - 1573
  • [13] Estimation of physical parameters of an induction motor using an indirect method
    Araújo, RE
    Leite, AV
    Freitas, DS
    ISIE 2002: PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-4, 2002, : 535 - 540
  • [14] A RAPID METHOD FOR ESTIMATION OF VIABLE CELL COUNT OF ESCHERICHIA-COLI AND YEAST USING ON OXYGEN SENSOR
    OHASHI, M
    OSHITANI, S
    OTSUKA, M
    ARAKAWA, N
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1991, 32 (02): : 71 - 77
  • [15] Online estimation of inlet contaminant concentration using Eulerian-Lagrangian method of fundamental solutions and Bayesian inference
    Dalla, Carlos Eduardo Rambalducci
    da Silva, Wellington Betencurte
    Dutra, Julio Cesar Sampaio
    Colaco, Marcelo Jose
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2024, 164 : 131 - 138
  • [17] Accurate estimation of subcritically using indirect bias estimation method .2. Applications
    Sakurai, K
    Yamamoto, T
    Arakawa, T
    Naito, Y
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1997, 34 (06) : 544 - 550
  • [18] ESTIMATION OF THE BLOOD HEMOGLOBIN CONCENTRATION USING SODIUM DODECYL-SULFATE
    AKHREM, AA
    ANDREYUK, GM
    KISELEVA, SN
    KISEL, MA
    KISELEV, PA
    DALNOVA, TS
    KOLB, VG
    SVETLITSKAYA, SG
    LABORATORNOE DELO, 1989, (05): : 13 - 15
  • [19] MEASUREMENTS OF LACTATE CONCENTRATION USING LACTATE OXIDASE AND AN ELECTROCHEMICAL OXYGEN SENSOR
    MAKOVOS, EB
    LIU, CC
    BIOTECHNOLOGY AND BIOENGINEERING, 1985, 27 (02) : 167 - 170
  • [20] Accurate estimation of subcriticality using indirect bias estimation method .1. Theory
    Yamamoto, T
    Sakurai, K
    Arakawa, T
    Naito, Y
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1997, 34 (05) : 454 - 460