Using Energy Particle Detection Technology on the Tiangong's Space Station's Wentian Laboratory Cabin Module

被引:4
|
作者
Shen, Guohong [1 ,2 ]
Zhang, Shenyi [1 ,2 ]
Zhang, Xianguo [1 ,2 ]
Zhang, Huanxin [1 ,2 ]
Yuan, Bin [1 ,2 ]
Hou, Donghui [1 ,2 ]
Wang, Chunqin [1 ,2 ]
Quan, Zida [1 ,2 ]
Yang, Zhe [3 ]
Sun, Yueqiang [1 ,2 ]
机构
[1] Chinese Acad Sci, Natl Space Sci Ctr, Beijing 100190, Peoples R China
[2] Beijing Key Lab Space Environm Explorat, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
关键词
Tiangong space station; Wentian laboratory cabin module; energy particle detector; neutron detection; heavy ion detection; LET spectrum; radiation dose; RADIATION ENVIRONMENT; SOLAR-WIND;
D O I
10.3390/aerospace10040373
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
To conduct real-time monitoring of the particle radiation environment in the orbit of the Tiangong space station, the installation of an energy particle detector operating on the outside of Wentian laboratory cabin module is proposed. Monitoring the energy, flux, and direction of high-energy protons, electrons, heavy ions, and neutrons in orbital space, as well as the LET spectrum and radiation dose rate generated by them, provides an important basis for studying the mechanism of the space environment that causes harm to space stations and astronauts. It also provides the necessary space environment parameters for the scientific experiment instruments on the space station. During its ground development process, the detector was verified by various calibration methods such as standard radioactive sources, equivalent signal generators, and particle accelerators. The results show that the detector can realize discrimination of particle ingredients (electrons, protons, heavy ions, and neutrons). Meanwhile, the measurement indexes can also realize target requirements, namely, from lower limit of 20 keV for medium-energy electrons and protons to heavy ion GeV, 0.025 eV similar to 100 MeV for neutrons, and 0.233 similar to 17,475 keV/mu m for the LET spectrum and 0.1 similar to 1000 mGy/day for the dose rate produced. The measurement precisions of all indexes are better than approximately 16%.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Estimation of the Effect of Orientation of International Space Station on the Dose Rate in Station's Service Module when Passing through the South-Atlantic Anomaly Region
    Drobyshev, S. G.
    Benghin, V. V.
    COSMIC RESEARCH, 2011, 49 (05) : 399 - 406
  • [32] Estimation of the effect of orientation of International Space Station on the dose rate in Station’s Service Module when passing through the South-Atlantic anomaly region
    S. G. Drobyshev
    V. V. Benghin
    Cosmic Research, 2011, 49 : 399 - 406
  • [33] The High cosmic-Radiation Detection (HERD) Facility onboard China's Future Space Station
    Zhang, S. N.
    Adriani, O.
    Albergo, S.
    Ambrosi, G.
    An, Q.
    Bao, T. W.
    Battiston, R.
    Bi, X. J.
    Cao, Z.
    Chai, J. Y.
    Chang, J.
    Chen, G. M.
    Chen, Y.
    Cui, X. H.
    Dai, Z. G.
    D'Alessandro, R.
    Dong, Y. W.
    Fan, Y. Z.
    Feng, C. Q.
    Feng, H.
    Feng, Z. Y.
    Gao, X. H.
    Gargano, F.
    Giglietto, N.
    Gou, Q. B.
    Guo, Y. Q.
    Hu, B. L.
    Hu, H. B.
    He, H. H.
    Huang, G. S.
    Huang, J.
    Huang, Y. F.
    Li, H.
    Li, L.
    Li, Y. G.
    Li, Z.
    Liang, E. W.
    Liu, H.
    Liu, J. B.
    Liu, J. T.
    Liu, S. B.
    Liu, S. M.
    Liu, X.
    Lu, J. G.
    Mazziotto, M. N.
    Mori, N.
    Orsi, S.
    Pearce, M.
    Pohl, M.
    Quan, Z.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [34] NUCLEAR POWER STATION TECHNOLOGY: CRUCIAL STRAND IN U. S. ENERGY LIFELINE.
    Roberts, Richard W.
    Professional Engineer (Washington, D.C.), 1976, 46 (04): : 30 - 33
  • [35] Pharmaceutical Research Enabled Through Microgravity: Perspectives on the Use of the International Space Station U.S. National Laboratory
    Marc A. Giulianotti
    Lucie A. Low
    Pharmaceutical Research, 2020, 37
  • [36] QRS detection using S-Transform and Shannon energy
    Zidelmal, Z.
    Amirou, A.
    Ould-Abdeslam, D.
    Moukadem, A.
    Dieterlen, A.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 116 (01) : 1 - 9
  • [37] 10Gb/s external modulator module using capacitive and inductive peaking technology
    Pan, B
    Gao, JJ
    Gao, BX
    FIBER OPTICS AND OPTOELECTRONICS FOR NETWORK APPLICATIONS, 2001, 4603 : 272 - 277
  • [38] Potential for Constraining Propagation Parameters of Galactic Cosmic Rays with the High Energy Cosmic-radiation Detection Facility on Board China's Space Station
    Zhi-Hui Xu
    Qiang Yuan
    Zhi-Cheng Tang
    Xiao-Jun Bi
    Research in Astronomy and Astrophysics, 2023, (08) : 292 - 298
  • [39] Potential for Constraining Propagation Parameters of Galactic Cosmic Rays with the High Energy Cosmic-radiation Detection Facility on Board China's Space Station
    Xu, Zhi-Hui
    Yuan, Qiang
    Tang, Zhi-Cheng
    Bi, Xiao-Jun
    RESEARCH IN ASTRONOMY AND ASTROPHYSICS, 2023, 23 (08)
  • [40] A detection method for bearing faults using null space pursuit and S transform
    Zhu, De
    Gao, Qingwei
    Sun, Dong
    Lu, Yixiang
    Peng, Silong
    SIGNAL PROCESSING, 2014, 96 : 80 - 89