Numerical Analysis of Restrained Continuous Steel Columns under Standard Fire

被引:1
|
作者
Sun, Jinhua [1 ]
Meng, Fanqin [2 ]
Andisheh, Kaveh [3 ]
Clifton, George Charles [4 ]
机构
[1] Univ Shanghai Sci & Technol, Audit Dept, Shanghai 200093, Peoples R China
[2] Heavy Engn Res Assoc, Struct Fire Res Engn, Auckland 2104, New Zealand
[3] Heavy Engn Res Assoc, Gen Manager Struct Syst, Auckland 2104, New Zealand
[4] Univ Auckland, Dept Civil & Environm Engn, Auckland 1023, New Zealand
来源
FIRE-SWITZERLAND | 2023年 / 6卷 / 09期
关键词
continuous steel columns; numerical modelling; axial restraint; fire resistance; limiting temperature; failure criterion; ELEVATED-TEMPERATURES; PART; PERFORMANCE; BEHAVIOR; DESIGN; STRENGTH;
D O I
10.3390/fire6090330
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
The steel column performance in realistic structures during a fire has yet to be fully understood because existing research emphasizes single-story performance, thereby disregarding the influence of continuous steel columns in multi-story configurations devoid of fire. This paper presents a numerical study to comprehend the overall structural fire performance of continuous steel columns, considering the effect of loading ratios, restraint ratios, column continuity, and single-sided lateral moments. An advanced numerical model was initially developed using ABAQUS and validated against experimental tests. The validated numerical model was subsequently employed to investigate the effects of several parameters, including axial restraint ratios (& alpha; = 0.05-0.35) and axial load ratios (n = 0.3-0.8). The study findings indicated that the restraint ratios within the designed range have a slightly beneficial impact on the fire resistance of continuous steel columns. The column continuity did not exert a significant impact on the performance of steel columns in fire. Additionally, the comparison showed that the current design approach in EN 1993-1-2 was conservative for predicting the limiting temperature of internal and edge columns.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Stability of axially restrained steel columns under temperature action
    CAI JianGuo FENG Jian ZHAO YaoZong XU YiXiang Key Laboratory of C PC Structures of Ministry of Education Southeast University Nanjing China Department of Civil Engineering Strathclyde University Glasgow G QQ United Kingdom
    Science China(Technological Sciences), 2010, 53 (12) : 3349 - 3355
  • [42] Stability of axially restrained steel columns under temperature action
    Key Laboratory of C and PC Structures, Ministry of Education, Southeast University, Nanjing 210096, China
    不详
    Sci. China Technol. Sci., 12 (3349-3355):
  • [43] Stability of axially restrained steel columns under temperature action
    CAI JianGuo1
    2 Department of Civil Engineering
    Science China(Technological Sciences), 2010, (12) : 3349 - 3355
  • [44] Stability of axially restrained steel columns under temperature action
    Cai JianGuo
    Feng Jian
    Zhao YaoZong
    Xu YiXiang
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (12) : 3349 - 3355
  • [45] Experimental analysis of built-up closed cold-formed steel columns with restrained thermal elongation under fire conditions
    Craveiro, Helder D.
    Rodrigues, Joao Paulo C.
    Laim, Luis
    THIN-WALLED STRUCTURES, 2016, 107 : 564 - 579
  • [46] Fire resistance design method for restrained stainless steel H-section columns under axial compression
    Ding, Runmin
    Fan, Shenggang
    Chen, Guoqiang
    Li, Chenxu
    Du, Erfeng
    Liu, Chengliang
    FIRE SAFETY JOURNAL, 2019, 108
  • [47] FIRE-RESISTANCE STUDY OF RESTRAINED STEEL COLUMNS WITH INITIAL LATERAL DISPLACEMENT
    Zhang, Jin
    Xu, Yi-Xiang
    Yang, Xiao-Jing
    Zhang, Dong-Hao
    ADVANCED STEEL CONSTRUCTION, 2018, 14 (01): : 22 - 36
  • [48] Rankine approach for fire resistance of axially-and-flexurally restrained steel columns
    Huang, ZF
    Tan, KH
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (12) : 1553 - 1571
  • [49] A simplified calculation method for fire design of steel columns with restrained thermal elongation
    Moura Correia, Antonio J. P.
    Rodrigues, Joao Paulo C.
    Gomes, Fernando C. T.
    COMPUTERS & STRUCTURES, 2013, 116 : 20 - 34
  • [50] Fire tests on restrained high strength Q460 steel columns
    College of Civil Engineering, Chongqing university, Chongqing
    400045, China
    不详
    400045, China
    Harbin Gongye Daxue Xuebao, 12 (93-97):