Impact of endodontic irrigants on surface roughness of various nickel-titanium rotary endodontic instruments

被引:2
|
作者
Hamdy, Tamer M. [1 ]
Alkabani, Yasmine Mohsen [1 ]
Ismail, Amira Galal [1 ]
Galal, Manar M. [1 ]
机构
[1] Natl Res Ctr NRC, Oral & Dent Res Inst, Restorat & Dent Mat Dept, Giza 12622, Egypt
关键词
Atomic Force Microscopy; Surface roughness; Irrigation; Sodium Hypochlorite; Ni-Ti; rotary instruments; SODIUM-HYPOCHLORITE; FATIGUE RESISTANCE; FILES; IRRIGATION; CORROSION; FRACTURE;
D O I
10.1186/s12903-023-03227-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe aim of the current study is to assess the surface roughness of several recent nickel-titanium (Ni-Ti) rotary endodontic instruments, namely: Protaper next (PTN); Hyflex CM (CM); Hyflex EDM (EDM); WaveOne gold (WOG); and trunatomy (TN), before and after application of 5.25% sodium hypochlorite (NaOCl) irrigant solution.MethodsIn this in vitro study, five recently introduced rotary endodontic instruments of different metallurgical properties and designs were subjected to Atomic Force Microscopy (AFM) analysis, and then each file was rotated in 5.25% NaOCl for 15 min., with speed and torque according to manufacturer's instructions. The instruments were then subjected to AFM analysis again. The surface roughness average (Sa) parameter was calculated. Data were analyzed by Paired T test, One-way ANOVA and Tukey tests.ResultsThere was a statistically significant decrease in the surface roughness of all rotary endodontic instruments after immersion in irrigants (P & LE; 0.05).ConclusionThe new TN and PTN instruments showed the least surface roughness. All tested Ni-Ti rotary endodontic instruments after irrigants exposure showed a varying increase in surface roughness.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] An In Vitro Cyclic Fatigue Analysis of Different Endodontic Nickel-Titanium Rotary Instruments
    Bhagabati, Nilav
    Yadav, Seema
    Talwar, Sangeeta
    JOURNAL OF ENDODONTICS, 2012, 38 (04) : 515 - 518
  • [22] Influence of Rotational Speed on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments
    Lopes, Helio P.
    Ferreira, Alessandra A. P.
    Elias, Carlos N.
    Moreira, Edson J. L.
    Machado de Oliveira, Julio C.
    Siqueira, Jose F., Jr.
    JOURNAL OF ENDODONTICS, 2009, 35 (07) : 1013 - 1016
  • [23] Evolution and development: engine-driven endodontic rotary nickel-titanium instruments
    Yuhong Liang
    Lin Yue
    International Journal of Oral Science, 2022, 14
  • [24] Evolution and development:engine-driven endodontic rotary nickel-titanium instruments
    Yuhong Liang
    Lin Yue
    International Journal of Oral Science, 2022, 14 (01) : 12 - 19
  • [25] Evolution and development:engine-driven endodontic rotary nickel-titanium instruments
    Yuhong Liang
    Lin Yue
    International Journal of Oral Science, 2022, (01) : 12 - 19
  • [26] Influence of structure on nickel-titanium endodontic instruments failure
    Kuhn, G
    Tavernier, B
    Jordan, L
    JOURNAL OF ENDODONTICS, 2001, 27 (08) : 516 - 520
  • [27] Effect of cryogenic treatment on nickel-titanium endodontic instruments
    Kim, JW
    Griggs, JA
    Regan, JD
    Ellis, RA
    Cai, Z
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (06) : 364 - 371
  • [28] A Comparative Computational Analysis of the Mechanical Behavior of Two Nickel-Titanium Rotary Endodontic Instruments
    Necchi, Silvia
    Petrini, Lorenza
    Taschieri, Silvio
    Migliavacca, Francesco
    JOURNAL OF ENDODONTICS, 2010, 36 (08) : 1380 - 1384
  • [29] Phase transformation behaviour and bending properties of hybrid nickel-titanium rotary endodontic instruments
    Hayashi, Y.
    Yoneyama, T.
    Yahata, Y.
    Miyai, K.
    Doi, H.
    Hanawa, T.
    Ebihara, A.
    Suda, H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (04) : 247 - 253
  • [30] Finite element analysis of rotary nickel-titanium endodontic instruments: A critical review of the methodology
    Chien, Philip Y-H
    Walsh, Laurence J.
    Peters, Ove A.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2021, 129 (05)