Design and evaluation of vascular interventional robot system for complex coronary artery lesions

被引:4
|
作者
Yu, Haoyang [1 ]
Wang, Hongbo [1 ,2 ,3 ]
Chang, Jiangyuan [4 ]
Liu, Wenjie [5 ]
Wang, Fuhao [2 ,3 ]
Niu, Jianye [1 ,5 ]
机构
[1] Yanshan Univ, Hebei Prov Key Lab Parallel Robot & Mechatron Syst, Qinhuangdao 066004, Peoples R China
[2] Fudan Univ, Acad Engn & Technol, Shanghai 200433, Peoples R China
[3] Shanghai Clin Res Ctr Aging & Med, Shanghai 200040, Peoples R China
[4] Third Hosp Qinhuangdao, Qinhuangdao 066001, Peoples R China
[5] Yanshan Univ, Key Lab Adv Forging & Stamping Technol & Sci, Minist Educ China, Qinhuangdao 066004, Peoples R China
关键词
Vascular interventional robot; Complex coronary artery lesions; Collaborative delivery; Force feedback; CATHETER;
D O I
10.1007/s11517-023-02775-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At present, most vascular intervention robots cannot cope with the more common coronary complex lesions in the clinic. Moreover, the lack of effective force feedback increases the risk of surgery. In this paper, a vascular interventional robot that can collaboratively deliver multiple interventional instruments has been developed to assist doctors in the operation of complex lesions. Based on the doctor's skills and the delivery principle of interventional instruments, the main and slave manipulators of the robot system are designed. Haptic force feedback is generated through resistance measuring mechanism and active drag system. In addition, a force feedback control strategy based on force-velocity mapping is proposed to realize the continuous change of force and avoid vibration. The proposed robot system was evaluated through a series of experiments. The experimental results show that the system can accurately measure the delivery resistance of interventional instruments, and provide haptic force feedback to doctors. The capability of the system to collaboratively deliver multiple interventional instruments is effective. Therefore, it can be considered that the robot system is feasible and effective.
引用
收藏
页码:1365 / 1380
页数:16
相关论文
共 50 条
  • [1] Design and evaluation of vascular interventional robot system for complex coronary artery lesions
    Haoyang Yu
    Hongbo Wang
    Jiangyuan Chang
    Wenjie Liu
    Fuhao Wang
    Jianye Niu
    [J]. Medical & Biological Engineering & Computing, 2023, 61 : 1365 - 1380
  • [2] Design and evaluation of a wearable vascular interventional surgical robot system
    Yu, Haoyang
    Wang, Hongbo
    Rong, Yu
    Fang, Junyu
    Niu, Jianye
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01):
  • [3] Design and performance evaluation of a novel vascular interventional surgery robot
    Li, Long
    Huang, Zhihui
    Tian, Yingzhong
    Wang, Wenbing
    Chen, Wei
    Li, Zexi
    Xi, Fengfeng
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 176 - 181
  • [4] Design and evaluation of sensorized robot for minimally vascular interventional surgery
    Xianqiang Bao
    Shuxiang Guo
    Liwei Shi
    Nan Xiao
    [J]. Microsystem Technologies, 2019, 25 : 2759 - 2766
  • [5] Design and evaluation of sensorized robot for minimally vascular interventional surgery
    Bao, Xianqiang
    Guo, Shuxiang
    Shi, Liwei
    Xiao, Nan
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2019, 25 (07): : 2759 - 2766
  • [6] Design and Performance Evaluation of Interventional Surgery Robot System
    Luo, Xiaoxiao
    Zhang, Sijie
    Mei, Ziyang
    Chen, Hongyu
    Hu, Jinhao
    Mao, Jingsong
    Zhou, Junqiang
    Zhao, Yang
    [J]. PROCEEDINGS OF 2022 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2022), 2022, : 70 - 74
  • [7] Design and Evaluation of a Learning-Based Vascular Interventional Surgery Robot
    Chen, Xingyu
    Chen, Yinan
    Duan, Wenke
    Akinyemi, Toluwanimi Oluwadara
    Yi, Guanlin
    Jiang, Jie
    Du, Wenjing
    Omisore, Olatunji Mumini
    [J]. FIBERS, 2022, 10 (12)
  • [8] Mechanism Design of the Minimally Invasive Vascular Interventional Surgery Robot System
    Liu, Haiyang
    Wang, Hongbo
    Yang, Xue
    Jin, Zhennan
    Wang, Qiang
    Li, Shanshan
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS (CIS) AND IEEE CONFERENCE ON ROBOTICS, AUTOMATION AND MECHATRONICS (RAM), 2017, : 225 - 230
  • [9] Design and Performance Evaluation of a Novel Vascular Robotic System for Complex Percutaneous Coronary Interventions
    Zhao, Han-Lin
    Liu, Shi-Qi
    Zhou, Xiao-Hu
    Xie, Xiao-Liang
    Hou, Zeng-Guang
    Zhou, Yan-Jie
    Zhang, Lin-Sen
    Gui, Mei-Jiang
    Wang, Jin-Li
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4679 - 4682
  • [10] Design of propulsion mechanism for vascular interventional operation robot
    Wang, Hongbo
    Tian, Hesuo
    Guo, Huanghuang
    Yang, Xue
    Tian, Yu
    Hu, Xinyu
    Chen, Jianyu
    [J]. 2018 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2018, : 172 - 177