Alternating Look-Locker for quantitative T1, T1? and B1 3D MRI mapping

被引:0
|
作者
Wu, Lin [1 ,2 ]
Carchi, Chris [1 ,2 ]
Michaeli, Shalom [1 ,2 ]
Mangia, Silvia [1 ,2 ]
Idiyatullin, Djaudat [1 ,2 ,3 ]
机构
[1] Univ Minnesota Med Sch, Ctr Magnet Resonance Res, Minneapolis, MN USA
[2] Univ Minnesota Med Sch, Dept Radiol, Minneapolis, MN USA
[3] Univ Minnesota, Ctr MR Res, Radiol Dept, Minneapolis, MN 55455 USA
关键词
B1-map; Look-Locker; rat brain; SWIFT; T-1; T-1 & rho; zero-TE; MAGNETIZATION-TRANSFER; ADIABATIC PULSES; SPIN-LOCKING; RELAXATION; RESONANCE; PHASE; REDUCTION; ARTIFACTS; CONTRAST; BRAIN;
D O I
10.1002/mrm.29839
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a new MRI method, entitled alternating Look-Locker (aLL), for quantitative T-1, T-1?, and B-1 3D mapping.Methods: A Look-Locker scheme that alternates magnetization from +Z and -Z axes of the laboratory frame is utilized in combination with a 3D Multi-Band Sweep Imaging with Fourier Transformation (MB-SWIFT) readout. The analytical solution describing the spin evolution during aLL, as well as the correction required for segmented acquisition were derived. The simultaneous B-1 and T-1 mapping are demonstrated on an agar/saline phantom and on an in-vivo rat head. T-1? relaxation was achieved by cyclically applying magnetization preparation (MP) modules consisting of two adiabatic pulses. T-1? values in the rat brain in-vivo and in a gadobenate dimeglumine (Gd-DTPA) phantom were compared to those obtained with a previously introduced steady-state (SS) method.Results: The accuracy and precision of the analytical solution was tested by Bloch simulations. With the application of MP modules, the aLL method provides simultaneous T(1 )and T-1? maps. Conversely, without it, the method can be used for simultaneous T-1 and B-1 mapping. T-1? values were similar with both aLL and SS techniques. However, the aLL method resulted in more robust quantita-tive mapping compared to the SS method. Unlike the SS method, the aLL method does not require additional scans for generating T-1 maps.Conclusion: The proposed method offers a new flexible tool for quantitative map-ping of T-1, T-1?, and B-1. The aLL method can also be used with readout schemes different from MB-SWIFT.
引用
收藏
页码:149 / 161
页数:13
相关论文
共 50 条
  • [31] Magnetization-prepared GRASP MRI for rapid 3D T1 mapping and fat/water-separated T1 mapping
    Feng, Li
    Liu, Fang
    Soultanidis, Georgios
    Liu, Chenyu
    Benkert, Thomas
    Block, Kai Tobias
    Fayad, Zahi A.
    Yang, Yang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (01) : 97 - 114
  • [32] A fast Look–Locker method for T1 mapping of the head and neck region
    Toru Chikui
    Kenji Tokumori
    Ryosuke Zeze
    Tomoko Shiraishi
    Takahiro Ichihara
    Masamitsu Hatakenaka
    Kazunori Yoshiura
    [J]. Oral Radiology, 2009, 25 : 22 - 29
  • [33] Three-dimensional Look-Locker MRI for evaluation of postcontrast myocardial and blood T1 values: comparison with two-dimensional Look-Locker and late gadolinium enhancement MRI
    Amano, Yasuo
    Tachi, Masaki
    Kumita, Shinichiro
    [J]. ACTA RADIOLOGICA, 2013, 54 (01) : 8 - 13
  • [34] A segmented modified look-locker inversion recovery (MOLLI) sequence for high heart rate T1 mapping of mice
    Maryam Nezafat
    Markus Henningsson
    Christian Stehning
    Mehmet Akcakaya
    Andrea Protti
    Rene Botnar
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [35] Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast-enhanced abdominal MRI
    Treier, Reto
    Steingoetter, Andreas
    Fried, Michael
    Schwizer, Werner
    Boesiger, Peter
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 568 - 576
  • [36] Modified Look-Locker T1 evaluation using Bloch simulations: Human and phantom validation
    Gai, Neville D.
    Stehning, Christian
    Nacif, Marcelo
    Bluemke, David A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 329 - 336
  • [37] Optimization of Look-Locker Turbo-Field Echo-Planar Imaging and Evaluation of Its Accuracy in Head and Neck 3D T1 Mapping
    Maehara, Masanori
    Monma, Masahiko
    Nitanai, Takeshi
    Matsumoto, Tetsuya
    Fukuma, Yukiko
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (03) : 288 - 298
  • [38] T1 mapping in cardiac MRI
    Dina Radenkovic
    Sebastian Weingärtner
    Lewis Ricketts
    James C. Moon
    Gabriella Captur
    [J]. Heart Failure Reviews, 2017, 22 : 415 - 430
  • [39] T1 mapping in cardiac MRI
    Radenkovic, Dina
    Weingaertner, Sebastian
    Ricketts, Lewis
    Moon, James C.
    Captur, Gabriella
    [J]. HEART FAILURE REVIEWS, 2017, 22 (04) : 415 - 430
  • [40] Shortened modified look-locker inversion recovery for myocardial T1 mapping in dilated cardiomyopathy and correlation with ejection fraction
    Sung, YMYon Mi
    Kim, Y. K.
    Ann, J.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 75 - 75