Test on fouling detection of ballast based on infrared thermography

被引:10
|
作者
Liang, Xiaolong [1 ,2 ]
Niu, Xinyu [1 ,2 ]
Liu, Poquan [1 ,2 ]
Lan, Caihao [1 ,2 ]
Yang, Rongshan [1 ,2 ]
Zhou, Zhiqiang [1 ,2 ]
机构
[1] Southwest Jiaotong Univ, MOE Key Lab High Speed Railway Engn, Chengdu 610031, Peoples R China
[2] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Peoples R China
关键词
Ballasted railway track; Fouling detection; Infrared thermography; Surface temperature; Experimental research; RAILWAY BALLAST; GRADATION;
D O I
10.1016/j.ndteint.2023.102956
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
To facilitate rapid, accurate, and convenient detection of ballast fouling, this paper proposes simplified computational models based on thermodynamic principles to analyze the surface temperature of clean and fouled ballast. The feasibility of employing infrared thermography for fouling detection on ballast is validated through analysis. Outdoor experiments are conducted to investigate the impact of various factors, such as the degree of fouling, the type of fouling, the intensity of solar radiation, and rainfall, on the surface temperature of the ballast. The research findings reveal that water exacerbates the difference in heat transfer rates between clean and fouled ballast. The fouled ballast has a higher thermal capacity compared to the clean ballast. In general, a lower fouling level and a higher solar radiation intensity result in a higher average surface temperature of the ballast when the external environment is stable and there is no shading. The intensity of solar radiation directly affects the temperature of the ballast surface. Additionally, the level of fouling primarily affects the temperature difference on the ballast surface for different degrees of fouling. When the percentage difference in average surface temperature between clean and fouled ballast exceeds 3.9% in this experiment, it is advisable to promptly assess the operational condition of the ballast and perform maintenance if necessary. On the sunny day, the temperature differences between the clean ballast and those with fouling levels of 20% and 40% are 1.22 degrees C and 2.01 degrees C, respectively. However, on the cloudy day, the maximum difference is only 0.3 degrees C. The temperature differences increase from 1.51 degrees C and 2.42 degrees C to 2.29 degrees C and 4.72 degrees C before and after rainfall, respectively. During nighttime, the average surface temperature of the ballast does not differ significantly between different levels of fouling. It is recommended to use infrared thermography for fouling detection on ballast during sunny afternoons or after rainfall. But further research is needed to explore its application during nighttime.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Detection of moisture in porous materials by infrared thermography
    Moropoulou, A
    Avdelidis, NP
    Haralampopoulos, G
    Anagnostopoulou, S
    THERMOSENSE XXIV, 2002, 4710 : 324 - 332
  • [32] Detection of carpal tunnel syndrome by infrared thermography
    Maxel, X.
    Bodnar, J. L.
    Stubbe, L.
    MECHANICS & INDUSTRY, 2014, 15 (05) : 363 - 370
  • [33] Detection of Dentinal Microcracks Using Infrared Thermography
    Matsushita-Tokugawa, Manami
    Miura, Jiro
    Iwami, Yukiteru
    Sakagami, Takahide
    Izumi, Yui
    Mori, Naoya
    Hayashi, Mikako
    Imazato, Satoshi
    Takeshige, Fumio
    Ebisu, Shigeyuki
    JOURNAL OF ENDODONTICS, 2013, 39 (01) : 88 - 91
  • [34] Active infrared thermography for land mine detection
    Galmiche, F
    Maldague, X
    DIAGNOSTIC IMAGING TECHNOLOGIES AND INDUSTRIAL APPLICATIONS, 1999, 3827 : 146 - 154
  • [35] Detection of wood damages using infrared thermography
    Pitarma, Rui
    Crisostomo, Joao
    Pereira, Livia
    16TH INTERNATIONAL CONFERENCE ON MOBILE SYSTEMS AND PERVASIVE COMPUTING (MOBISPC 2019),THE 14TH INTERNATIONAL CONFERENCE ON FUTURE NETWORKS AND COMMUNICATIONS (FNC-2019),THE 9TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY, 2019, 155 : 480 - 486
  • [36] Application of PCA in Concrete Infrared Thermography Detection
    An Ning
    Xie Jun
    Zheng Xiaohua
    Gao Xiaoni
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL WORKSHOP ON MATERIALS ENGINEERING AND COMPUTER SCIENCES (IWMECS 2015), 2015, 33 : 813 - 818
  • [37] Detection of Respiratory Rate of Dairy Cows Based on Infrared Thermography and Deep Learning
    Zhao, Kaixuan
    Duan, Yijie
    Chen, Junliang
    Li, Qianwen
    Hong, Xing
    Zhang, Ruihong
    Wang, Meijia
    AGRICULTURE-BASEL, 2023, 13 (10):
  • [38] Analysis of infrared thermography during tensile test of GFRP
    Jin-Woo, Kim
    Dong-Gi, Lee
    Jae-Ki, Sim
    Jae-Yeol, Kim
    Seung-Hyun, Choi
    MULTI-FUNCTIONAL MATERIALS AND STRUCTURES, PTS 1 AND 2, 2008, 47-50 : 1129 - +
  • [39] Study on Infrared Thermography Mosaic Algorithm Based on the Feature Point Detection and Registration
    Jiang, Jitong
    Song, Chao
    An, Jun
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 1138 - 1142
  • [40] Analysis of thermograph and experimental research based on the air tightness detection of infrared thermography
    Tian, Pengfei
    Zhou, Jiping
    Zhu, Xinlong
    Cao, Jin
    Journal of Applied Sciences, 2013, 13 (10) : 1710 - 1715