Test on fouling detection of ballast based on infrared thermography

被引:10
|
作者
Liang, Xiaolong [1 ,2 ]
Niu, Xinyu [1 ,2 ]
Liu, Poquan [1 ,2 ]
Lan, Caihao [1 ,2 ]
Yang, Rongshan [1 ,2 ]
Zhou, Zhiqiang [1 ,2 ]
机构
[1] Southwest Jiaotong Univ, MOE Key Lab High Speed Railway Engn, Chengdu 610031, Peoples R China
[2] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Peoples R China
关键词
Ballasted railway track; Fouling detection; Infrared thermography; Surface temperature; Experimental research; RAILWAY BALLAST; GRADATION;
D O I
10.1016/j.ndteint.2023.102956
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
To facilitate rapid, accurate, and convenient detection of ballast fouling, this paper proposes simplified computational models based on thermodynamic principles to analyze the surface temperature of clean and fouled ballast. The feasibility of employing infrared thermography for fouling detection on ballast is validated through analysis. Outdoor experiments are conducted to investigate the impact of various factors, such as the degree of fouling, the type of fouling, the intensity of solar radiation, and rainfall, on the surface temperature of the ballast. The research findings reveal that water exacerbates the difference in heat transfer rates between clean and fouled ballast. The fouled ballast has a higher thermal capacity compared to the clean ballast. In general, a lower fouling level and a higher solar radiation intensity result in a higher average surface temperature of the ballast when the external environment is stable and there is no shading. The intensity of solar radiation directly affects the temperature of the ballast surface. Additionally, the level of fouling primarily affects the temperature difference on the ballast surface for different degrees of fouling. When the percentage difference in average surface temperature between clean and fouled ballast exceeds 3.9% in this experiment, it is advisable to promptly assess the operational condition of the ballast and perform maintenance if necessary. On the sunny day, the temperature differences between the clean ballast and those with fouling levels of 20% and 40% are 1.22 degrees C and 2.01 degrees C, respectively. However, on the cloudy day, the maximum difference is only 0.3 degrees C. The temperature differences increase from 1.51 degrees C and 2.42 degrees C to 2.29 degrees C and 4.72 degrees C before and after rainfall, respectively. During nighttime, the average surface temperature of the ballast does not differ significantly between different levels of fouling. It is recommended to use infrared thermography for fouling detection on ballast during sunny afternoons or after rainfall. But further research is needed to explore its application during nighttime.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Advancing railway infrastructure maintenance: Thermodynamic parameter inversion of ballast bed and feasibility assessment of fouling detection via infrared thermography (IRT)
    Liang, Xiaolong
    Yang, Rongshan
    Liu, Poquan
    Niu, Xinyu
    Zhang, Qiang
    Ding, Haozhe
    Geng, Haonan
    Chen, Jiaxiang
    INFRARED PHYSICS & TECHNOLOGY, 2024, 141
  • [2] Membrane fouling characterization by infrared thermography
    Ndukaife, Kennethrex O.
    Ndukaife, Justus C.
    Nnanna, A. G. Agwu
    INFRARED PHYSICS & TECHNOLOGY, 2015, 68 : 186 - 192
  • [3] Non-destructive assessment of railway ballast fouling and water retention using infrared thermography and statistical processing
    Koohmishi, Mehdi
    Gao, Yansong
    Jing, Guoqing
    Guo, Yunlong
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 466
  • [5] Detection and location of fouling on photovoltaic panels using a drone-mounted infrared thermography system
    Zhang, Peng
    Zhang, Lifu
    Wu, Taixia
    Zhang, Hongming
    Sun, Xuejian
    JOURNAL OF APPLIED REMOTE SENSING, 2017, 11
  • [6] Infrared Thermography for Moisture Detection: A Laboratory Study and In-situ Test
    Grinzato, Ermanno
    Ludwig, Nicola
    Cadelano, Gianluca
    Bertucci, Michele
    Gargano, Marco
    Bison, Paolo
    MATERIALS EVALUATION, 2011, 69 (01) : 97 - 104
  • [7] Evaluation Standard of Ballast Fouling Based on Permeability
    Qie L.
    Xu Y.
    Li M.
    Wang H.
    Wang Z.
    Zhongguo Tiedao Kexue/China Railway Science, 2020, 41 (02): : 18 - 23
  • [8] Infrared thermography observations of crystallization fouling in a plate heat exchanger
    Berce, Jure
    Zupancic, Matevz
    Moze, Matic
    Golobic, Iztok
    APPLIED THERMAL ENGINEERING, 2023, 224
  • [9] Damage detection of composites based on ultrasonic infrared thermography technique
    Song, Y.-J., 2012, Journal of Solid Rocket Technology, P.O. Box 120, Xi'an, 710025, China (35):
  • [10] Detection of IGBT degradation in NPC inverter based on infrared thermography
    Chen, Danjiang
    Liu, Yutian
    Zhang, Wei
    Zheng, Minhua
    Zhang, Shaozhong
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2018, 18 (02) : 459 - 468