Adhesion and Activation of Blood Platelets on Laser-Structured Surfaces of Biomedical Metal Alloys

被引:3
|
作者
Kaminska, Marta [1 ]
Jastrzebska, Aleksandra [1 ]
Walkowiak-Przybylo, Magdalena [1 ,2 ]
Walczynska, Marta [1 ,3 ]
Komorowski, Piotr [1 ,4 ]
Walkowiak, Bogdan [1 ,4 ]
机构
[1] Lodz Univ Technol, Inst Mat Sci & Engn, Dept Biophys, Stefanowskiego 1-15, PL-90537 Lodz, Poland
[2] Aflofarm Farm Polska Sp z o o, PL-95200 Pabianice, Poland
[3] Med Univ Lodz, Dept Med Imaging Tech, Lindley 6, PL-90131 Lodz, Poland
[4] Bionanopark Sp Z O O, Bionanopark Labs, Dubois 114-116, PL-93465 Lodz, Poland
关键词
metallic biomaterials; laser surface modification; platelet adhesion; platelet activation; platelet aggregation;
D O I
10.3390/jfb14090478
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser surface modification of metallic implants presents a promising alternative to other surface modification techniques. A total of four alloyed metallic biomaterials were used for this study: medical steel (AISI 316L), cobalt-chromium-molybdenum alloy (CoCrMo) and titanium alloys (Ti6Al4V and Ti6Al7Nb). Samples of metallic biomaterials after machining were subjected to polishing or laser modification in two different versions. The results of surface modification were documented using SEM imaging and roughness measurement. After modification, the samples were sterilized with dry hot air, then exposed to citrate blood, washed with PBS buffer, fixed with glutaraldehyde, sputtered with a layer of gold and imaged using SEM to enable the quantification of adhered, activated and aggregated platelets on the surface of biomaterial samples. The average total number, counted in the field of view, of adhered platelets on the surfaces of the four tested biomaterials, regardless of the type of modification, did not differ statistically significantly (66 +/- 81, 67 +/- 75, 61 +/- 70 and 57 +/- 61 for AISI 316L, CoCrMo, Ti6Al4V and Ti6Al7Nb, respectively) and the average number of platelet aggregates was statistically significantly higher (p < 0.01) on the surfaces of AISI 316L medical steel (42 +/- 53) and of the CoCrMo alloy (42 +/- 52) compared to the surfaces of the titanium alloys Ti6Al4V (33 +/- 39) and Ti6Al7Nb (32 +/- 37). Remaining blood after contact was used to assess spontaneous platelet activation and aggregation in whole blood by flow cytometry. An in-depth analysis conducted on the obtained results as a function of the type of modification indicates small but statistically significant differences in the interaction of platelets with the tested surfaces of metallic biomaterials.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] ROLE OF COMPLEMENT ACTIVATION IN CELL-ADHESION TO POLYMER BLOOD CONTACT SURFACES
    HERZLINGER, GA
    CUMMING, RD
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1980, 26 : 165 - 171
  • [42] Biomechanical activation of blood platelets via adhesion to von Willebrand factor studied with mesoscopic simulations
    Belyaev, Aleksey V.
    Kushchenko, Yulia K.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2023, 22 (03) : 785 - 808
  • [43] Biomechanical activation of blood platelets via adhesion to von Willebrand factor studied with mesoscopic simulations
    Aleksey V. Belyaev
    Yulia K. Kushchenko
    Biomechanics and Modeling in Mechanobiology, 2023, 22 : 785 - 808
  • [44] Anisotropic Ice Adhesion of Micro-Nano-Structured Metal Surface by a Femtosecond Laser
    Liu, Ziyuan
    Tao, Haiyan
    Lin, Jingquan
    LANGMUIR, 2021, 37 (31) : 9571 - 9576
  • [45] LASER-INDUCED ADHESION ENHANCEMENT OF POLYMER COMPOSITES AND METAL-ALLOYS
    BUCHMAN, A
    DODIUK, H
    ROTEL, M
    ZAHAVI, J
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 1994, 8 (10) : 1211 - 1224
  • [46] Adhesion of blood platelets under flow to wettability gradient polyethylene surfaces made in a shielded gas plasma
    Spijker, HT
    Bos, R
    Busscher, HJ
    Graaff, R
    van Oeveren, W
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2002, 16 (13) : 1703 - 1713
  • [47] Ultra-broadband enhanced absorption of metal surfaces structured by femtosecond laser pulses
    Yang, Yang
    Yang, Jianjun
    Liang, Chunyong
    Wang, Hongshui
    OPTICS EXPRESS, 2008, 16 (15) : 11259 - 11265
  • [48] Bacterial adhesion to direct laser metal formed and mildly acid etched implant surfaces
    Annunziata, M.
    Rizzo, A.
    Leone, C.
    Mangano, C.
    Mazzola, N.
    Nastri, L.
    Papale, F.
    Rullo, F.
    Guida, L.
    SURFACE & COATINGS TECHNOLOGY, 2017, 328 : 390 - 397
  • [49] MICROSTRUCTURE OF POLYSTYRENE-POLYAMIDE BLOCK COPOLYMERS AND ADHESION BEHAVIOR OF BLOOD-PLATELETS ONTO THE COPOLYMER SURFACES
    SANO, M
    YUI, N
    SANUI, K
    OGATA, N
    KATAOKA, K
    OKANO, T
    SAKURAI, Y
    KOBUNSHI RONBUNSHU, 1985, 42 (10) : 655 - 662
  • [50] ELLIPSOMETRIC STUDIES ON HUMAN-BLOOD PLATELET-ADHESION TO METAL-SURFACES
    ASLANIAN, D
    VAINER, H
    VUYE, G
    GUESDON, JP
    BALKANSKI, M
    INTERNATIONAL JOURNAL OF QUANTUM CHEMISTRY, 1977, 12 : 149 - 152