Control of mean arterial pressure using a closed-loop system for norepinephrine infusion in severe brain injury patients: the COMAT randomized controlled trial

被引:1
|
作者
Joosten, Alexandre [1 ]
Rinehart, Joseph [2 ]
Cannesson, Maxime [1 ]
Coeckelenbergh, Sean [3 ,4 ]
Pochard, Jonas [5 ]
Vicaut, Eric [6 ]
Duranteau, Jacques [5 ]
机构
[1] Univ Calif Los Angeles, Ronald Reagan Med Ctr, David Geffen Sch Med, Dept Anesthesiol & Perioperat Med, 757 Westwood Plaza, Los Angeles, CA 90095 USA
[2] Univ Calif Irvine, Dept Anesthesiol & Perioperat Care, Irvine, CA 92868 USA
[3] Univ Paris Saclay, Hop Paul Brousse, Assistance Publ Hop Paris, Dept Anesthesiol, Villejuif, France
[4] Outcomes Res Consortium, Cleveland, OH USA
[5] Univ Paris Saclay, Hop Bicetre, Assistance Publ Hop Paris, Dept Intens Care, Le Kremlin Bicetre, France
[6] Paris 7 Diderot Univ, Lariboisiere Univ Hosp, Assistance Publ Hop Paris AP HP, Unite Rech Clin, Paris, France
关键词
Arterial pressure; Hemodynamics; Automation; Perfusion pressure; Neurocritical care; MANAGEMENT; METAANALYSIS; SURGERY;
D O I
10.1007/s10877-023-01119-w
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Brain injury patients require precise blood pressure (BP) management to maintain cerebral perfusion pressure (CPP) and avoid intracranial hypertension. Nurses have many tasks and norepinephrine titration has been shown to be suboptimal. This can lead to limited BP control in patients that are in critical need of cerebral perfusion optimization. We have designed a closed-loop vasopressor (CLV) system capable of maintaining mean arterial pressure (MAP) in a narrow range and we aimed to assess its performance when treating severe brain injury patients. Within the first 48 h of intensive care unit (ICU) admission, 18 patients with a severe brain injury underwent either CLV or manual norepinephrine titration. In both groups, the objective was to maintain MAP in target (within +/- 5 mmHg of a predefined target MAP) to achieve optimal CPP. Fluid administration was standardized in the two groups. The primary objective was the percentage of time patients were in target. Secondary outcomes included time spent over and under target. Over the four-hour study period, the mean percentage of time with MAP in target was greater in the CLV group than in the control group (95.8 +/- 2.2% vs. 42.5 +/- 27.0%, p < 0.001). Severe undershooting, defined as MAP < 10 mmHg of target value was lower in the CLV group (0.2 +/- 0.3% vs. 7.4 +/- 14.2%, p < 0.001) as was severe overshooting defined as MAP > 10 mmHg of target (0.0 +/- 0.0% vs. 22.0 +/- 29.0%, p < 0.001). The CLV system can maintain MAP in target better than nurses caring for severe brain injury patients.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 50 条
  • [41] Application of Dragonfly Algorithm-Based Interval Type-2 Fuzzy Logic Closed-Loop Control System to Regulate the Mean Arterial Blood Pressure
    Sharma, Richa (richas@nitj.ac.in), 1600, Springer Science and Business Media Deutschland GmbH (831):
  • [42] Evaluation of Automated Delivery of Propofol Using a Closed-Loop Anesthesia Delivery System in Patients Undergoing Thoracic Surgery: A Randomized Controlled Study
    Sethi, Nitin
    Dutta, Amitabh
    Puri, Goverdhan D.
    Panday, Bhuwan C.
    Sood, Jayashree
    Gupta, Manish
    Choudhary, Prabhat K.
    Sharma, Shikha
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (04) : 1089 - 1095
  • [43] Closed-Loop Feedback Computer-Controlled Phenylephrine for Maintenance of Blood Pressure During Spinal Anesthesia for Cesarean Delivery: A Randomized Trial Comparing Automated Boluses Versus Infusion
    Ngan Kee, Warwick D.
    Tam, Yuk-Ho
    Khaw, Kim S.
    Ng, Floria F.
    Lee, Shara W. Y.
    ANESTHESIA AND ANALGESIA, 2017, 125 (01): : 117 - 123
  • [44] Performance of a dual-hormone closed-loop system versus insulin-only closed-loop system in adolescents with type 1 diabetes. A single-blind, randomized, controlled, crossover trial
    Lindkvist, Emilie Bundgaard
    Laugesen, Christian
    Reenberg, Asbjorn Thode
    Ritschel, Tobias Kasper Skov
    Svensson, Jannet
    Jorgensen, John Bagterp
    Norgaard, Kirsten
    Ranjan, Ajenthen G. G.
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [45] Electroacupuncture in Treatment of Acute Gastrointestinal Injury in Patients with Severe Traumatic Brain Injury: A Multicenter Randomized Controlled Trial
    Xing Xi
    Jiang Rong-lin
    Lei Shu
    Zhi Yi-hui
    Zhu Mei-fei
    Huang Li-quan
    Hu Ma-hong
    Lu Jun
    Fang Kun
    Wang Qiu-yan
    CHINESE JOURNAL OF INTEGRATIVE MEDICINE, 2023, 29 (08) : 721 - 729
  • [46] Electroacupuncture in Treatment of Acute Gastrointestinal Injury in Patients with Severe Traumatic Brain Injury:A Multicenter Randomized Controlled Trial
    XING Xi
    JIANG Rong-lin
    LEI Shu
    ZHI Yi-hui
    ZHU Mei-fei
    HUANG Li-quan
    HU Ma-hong
    LU Jun
    FANG Kun
    WANG Qiu-yan
    Chinese Journal of Integrative Medicine , 2023, (08) : 721 - 729
  • [47] Electroacupuncture in Treatment of Acute Gastrointestinal Injury in Patients with Severe Traumatic Brain Injury:A Multicenter Randomized Controlled Trial
    XING Xi
    JIANG Ronglin
    LEI Shu
    ZHI Yihui
    ZHU Meifei
    HUANG Liquan
    HU Mahong
    LU Jun
    FANG Kun
    WANG Qiuyan
    Chinese Journal of Integrative Medicine, 2023, 29 (08) : 721 - 729
  • [48] Electroacupuncture in Treatment of Acute Gastrointestinal Injury in Patients with Severe Traumatic Brain Injury: A Multicenter Randomized Controlled Trial
    Xi Xing
    Rong-lin Jiang
    Shu Lei
    Yi-hui Zhi
    Mei-fei Zhu
    Li-quan Huang
    Ma-hong Hu
    Jun Lu
    Kun Fang
    Qiu-yan Wang
    Chinese Journal of Integrative Medicine, 2023, 29 : 721 - 729
  • [49] Anaesthetic depth control using closed loop anaesthesia delivery system vs. target controlled infusion in patients with moderate to severe left ventricular systolic dysfunction
    Mahajan, V.
    Samra, T.
    Puri, G. D.
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 42 : 106 - 113
  • [50] Closed loop automated drug infusion regulation based on optimal 2-DOF TID control approach for the mean arterial blood pressure
    Karahan, Oguzhan
    Karci, Hasan
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2025,