摘要
Results of the experiments on drying of skin-forming material sprayed with two nozzles in counter-current pilot spray dryer are presented in the article. Phase Doppler Anemometry (PDA) measurements were conducted above, between, and below two nozzles spraying upward and downward which allowed us to track changes of particle size distribution (PSD) and particle velocities in the tower for different nozzle configurations. The analysis of PSD shows that for two nozzles pointing downwards, the drying zone was observed under the lower nozzle whereas the agglomeration zone develops between nozzles. For the upward orientation of the lower nozzle, a zone of simultaneous drying and agglomeration forms between the nozzles. Analysis of product moisture content, PSD, and bulk density showed the effect of nozzle configuration on product properties.
引用
收藏
页码:674 / 684
页数:11
相关论文
共 50 条
  • [11] Counter-current spray drying with stream separation: Computational modeling of a novel dryer design
    Soltani, Soheil
    Gerde, Per
    Acevedo, Fernando
    Rasmuson, Anders
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2015, 93 : 163 - 173
  • [12] Analytical Modeling of Counter-Current Drying Process
    Pamuk, M. T.
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2024, 27 (02) : 27 - 36
  • [13] A one-dimensional plug-flow model of a counter-current spray drying tower
    Ali, Muzammil
    Mahmud, Tariq
    Heggs, Peter John
    Ghadiri, Mojtaba
    Djurdjevic, Dusan
    Ahmadian, Hossein
    de Juan, Luis Martin
    Amador, Carlos
    Bayly, Andrew
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2014, 92 (05): : 826 - 841
  • [14] Particle aggregation in large counter-current spray drying towers: Nozzle configuration, vortex momentum and temperature
    Francia, Victor
    Martin, Luis
    Bayly, Andrew E.
    Simmons, Mark J. H.
    NEW PARADIGM OF PARTICLE SCIENCE AND TECHNOLOGY, PROCEEDINGS OF THE 7TH WORLD CONGRESS ON PARTICLE TECHNOLOGY, 2015, 102 : 668 - 675
  • [15] Residence time distribution of glass ballotini in isothermal swirling flows in a counter-current spray drying tower
    Ali, Muzammil
    Mahmud, Tariq
    Heggs, Peter
    Ghadiri, Mojtaba
    Bayly, Andrew
    Crosby, Mark
    Ahmadian, Hossein
    Martindejuan, Luis
    Alam, Zayeed
    POWDER TECHNOLOGY, 2017, 305 : 809 - 815
  • [16] CFD Simulation of a Counter-Current Spray Drying Tower with Stochastic Treatment of Particle-Wall Collision
    Ali, Muzammil
    Mahmud, Tariq
    Heggs, Peter John
    Ghadiri, Mojtaba
    Bayly, Andrew
    Ahmadian, Hossein
    de Juan, Luis Martin
    NEW PARADIGM OF PARTICLE SCIENCE AND TECHNOLOGY, PROCEEDINGS OF THE 7TH WORLD CONGRESS ON PARTICLE TECHNOLOGY, 2015, 102 : 1284 - 1294
  • [17] Agglomeration in counter-current spray drying towers. Part A: Particle growth and the effect of nozzle height
    Francia, Victor
    Martin, Luis
    Bayly, Andrew E.
    Simmons, Mark J. H.
    POWDER TECHNOLOGY, 2016, 301 : 1330 - 1343
  • [18] In-situ crystallization of particles in a counter-current spray dryer
    Shakiba, S.
    Mansouri, S.
    Selomulya, C.
    Woo, M. W.
    ADVANCED POWDER TECHNOLOGY, 2016, 27 (06) : 2299 - 2307
  • [19] Agglomeration in counter-current spray drying towers. Part B: Interaction between multiple spraying levels
    Francia, Victor
    Martin, Luis
    Bayly, Andrew E.
    Simmons, Mark J. H.
    POWDER TECHNOLOGY, 2016, 301 : 1344 - 1358
  • [20] ANALYSIS OF COUNTER-CURRENT DISTRIBUTION CURVES
    NEWTON, GGF
    ABRAHAM, EP
    NATURE, 1952, 169 (4289) : 69 - 69