COMPARISON OF HYBRID TECHNIQUES WITH 3D-CONFORMAL RADIOTHERAPY IN PATIENTS WITH LUNG CANCER

被引:0
|
作者
Azaklioglu, Oemer [1 ]
Akcay, Dogukan [2 ,3 ]
Er, Ilhami [4 ]
Akguengoer, Kadir [3 ,5 ]
Demiral, Ayse Nur [2 ,3 ]
机构
[1] Prof Dr Cemil Tascioglu Res & Training City Hosp, Clin Radiat Oncol, Istanbul, Turkiye
[2] Dokuz Eylul Univ, Fac Med, Dept Radiat Oncol, Izmir, Turkiye
[3] Dokuz Eylul Univ, Inst Hlth Sci, Dept Med Phys, Izmir, Turkiye
[4] Izmir Ataturk Res & Training Hosp, Clin Radiat Oncol, Izmir, Turkiye
[5] Dokuz Eylul Univ, Fac Sci, Dept Phys, Izmir, Turkiye
来源
关键词
hybrid technique; intensity modulated radiation therapy; lung cancer; radiotherapy; treatment planning; volumetric modulated arc therapy; VOLUMETRIC MODULATED ARC; VMAT TECHNIQUE; IMRT; THERAPY;
D O I
10.30621/jbachs.1168222
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: It's postulated that hybrid techniques (HT) with lower weighting of IMRT/VMAT component would improve lung dose-volume parameters despite some disadvantage in PTV homogeneity index (HI) and target coverage (TC). Material and Methods: Conformal plans were prepared using 6-10-15 MV-X photon energies while IMRT/VMAT plans of HTs were prepared using 6MV-X. Four HTs were developed having two different ratios (10% and 50%) of IMRT/VMAT component (h-IMRT1, h-IMRT2 and h-VMAT1, h-VMAT2, respectively). HTs were compared with 3D-CRT in terms of HI and TC for PTV, and total lung (TL) and contralateral lung (CL) V5Gy, V10Gy, V20Gy and mean lung dose (MLD). Results: All HTs were advantageous for HI and TC, while disadvantageous for TL and CL-V5Gy. H-IMRT2 provided better TC than h-IMRT1, and so did h-VMAT2 compared to h-VMAT1. Lower weighting of IMRT/VMAT decreased TL and CL-V5Gy in HTs. In addition, h-IMRT1 decreased TL and CL-MLD and CLV20Gycompared to h-IMRT2, while h-VMAT2 decreased TL-V20Gy and CL-MLD compared to h-VMAT2. Conclusion: In the RT of lung tumors close to vertebra, it may be appropriate to suggest a ratio of IMRT/VMAT component approximately 10% in order to decrease the low and intermediate dose-wash lung volume, if HI and TC values are acceptable.
引用
收藏
页码:50 / 57
页数:8
相关论文
共 50 条
  • [21] COMPARATIVE STUDY OF CONVENTIONAL AND 3D-CONFORMAL RADIOTHERAPY IN LOCALLY ADVANCED LUNG CANCER IN CONCOMITANT CHEMO-RADIOTHERAPY PROTOCOLS
    Dastidar, Aloke Ghosh
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S832 - S833
  • [22] Radiobiological Effectiveness of 3D-Conformal Radiotherapy, MLC-Based IMRT and Helical Tomotherapy in Lung Cancer
    Delichas, M.
    Ferreira, B.
    Shi, C.
    Gutierrez, A.
    Lind, B.
    Papanikolaou, N.
    Mavroidis, P.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2821 - 2822
  • [23] Outcome and safety analysis of endometrial cancer patients treated with postoperative 3D-conformal radiotherapy or intensity modulated radiotherapy
    Onal, Cem
    Sari, Sezin Yuce
    Yavas, Guler
    Oymak, Ezgi
    Birgi, Sumerya Duru
    Yigit, Ecem
    Guler, Ozan Cem
    Gultekin, Melis
    Akyurek, Serap
    Yildiz, Ferah
    [J]. ACTA ONCOLOGICA, 2021, 60 (09) : 1154 - 1160
  • [24] Monocentric Comparison of Toxicity after intensity modulated Rotation Radiation and 3D-conformal Radiotherapy of Cervical Cancer
    Droege, L. H.
    von Sivers, F. F.
    Weber, H. E.
    Guhlich, M.
    Leu, M.
    Hennies, S.
    Rave-Fraenk, M.
    Hess, C. F.
    Wolff, H. A.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S136 - S136
  • [25] Feasibility of TomoDirect 3D-conformal Radiotherapy for Craniospinal Irradiation
    Kim, J.
    Jeong, K.
    Chung, Y.
    Choi, W.
    Woo, J.
    Baek, J.
    Bak, J.
    Cho, J.
    Cho, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S828 - S828
  • [26] From 3D-conformal radiotherapy to IMRT: fact or fiction
    Maingon, P
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S70 - S70
  • [27] Volumetric modulated arc therapy (VMAT) comparison to 3D-conformal technique in lung stereotactic ablative radiotherapy (SABR)
    Mark, Frances
    Alnsour, Anoud
    Penfold, Scott N.
    Esterman, Adrian
    Keys, Robert
    Le, Hien
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2023, 70 (01) : 72 - 80
  • [28] Clinical outcome and toxicity of 3D-conformal radiotherapy combined with chemotherapy for gastric cancer
    Glinski, K.
    Wasilewska-Tesluk, E.
    Rucinska, M.
    Cieslak-Zeranska, E.
    Czeremszynska, B.
    Osowiecka, K.
    Kepka, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S649 - S649
  • [29] Radical 3D-conformal radiotherapy and imrt of organ-confined prostate cancer
    Greco, C
    [J]. TUMORI, 2003, : S145 - S146
  • [30] A COMPARISON OF HELICAL INTENSITY-MODULATED RADIOTHERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D-CONFORMAL RADIATION THERAPY FOR PANCREATIC CANCER
    Poppe, Matthew M.
    Narra, Venkat
    Yue, Ning J.
    Zhou, Jinghao
    Nelson, Carl
    Jabbour, Salma K.
    [J]. MEDICAL DOSIMETRY, 2011, 36 (04) : 351 - 357