Hydraulic conductivity of GCL overlap permeated with saline solutions

被引:5
|
作者
Gastelo, Jackeline [1 ]
Li, Dong [1 ]
Tian, Kuo [1 ]
Tanyu, Burak F. [1 ]
Guler, Erol [1 ]
机构
[1] George Mason Univ, Dept Civil Environm & Infrastruct Engn, Fairfax, VA 22030 USA
关键词
Geosynthetics; Geosynthetic clay liner (GCL); Hydraulic conductivity; GCL overlap; Vertical flow; Horizontal flow; GEOSYNTHETIC CLAY LINERS; TRANSMISSIVITY; HYDRATION; WATER;
D O I
10.1016/j.wasman.2022.12.028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hydraulic conductivity of the overlap region of two needle-punched sodium bentonite (Na-B) geosynthetic clay liners (GCLs) permeated with CaCl2 solutions under confining stresses of 20, 100, 250, and 500 kPa were evaluated. One of the GCLs consisted of a uniform layer of Na-B encapsulated between a nonwoven (NW) and a woven (W) geotextile, and the other one consisted of NW geotextiles on both sides. Supplemental bentonite was placed within the overlap region. Experiments were conducted with 10, 20, and 50 mM CaCl2 solutions representing dilute and aggressive leachates. The results indicate that in most of the scenarios there is a possibility that the flow is not completely vertical (meaning flow passes through the overlap region horizontally). As the confining stress increased, the horizontal flow through the overlap region for GCLs reduced effectively when permeated with deionized water and 10 mM CaCl2 solution, whereas the reduction of horizontal flow was limited to 20 mM and 50 mM CaCl2 solutions.
引用
收藏
页码:348 / 356
页数:9
相关论文
共 50 条
  • [31] Hydraulic conductivity and swell of nonprehydrated geosynthetic clay liners permeated with multispecies inorganic solutions (vol 130, pg 1236, 2004)
    Kolstad, Dale C.
    Benson, Craig H.
    Edil, Tuncer B.
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2006, 132 (07) : 962 - 962
  • [32] The Positive Effects of Nanoclay on the Hydraulic Conductivity of Compacted Kahrizak Clay Permeated With Landfill Leachate
    Kananizadeh, Negin
    Ebadi, Taghi
    Khoshniat, Seyed Alireza
    Mousavirizi, Seyed Ehsan
    CLEAN-SOIL AIR WATER, 2011, 39 (07) : 605 - 611
  • [33] Effect of viscosity on the hydraulic conductivity of clayey soils permeated with water-soluble organics
    Fernandez, F.
    Quigley, R.M.
    1600, Canadian Geotechnical Soc, Montreal, Canada
  • [34] Comparison of laboratory-measured GCL hydraulic conductivity based on three permeameter types
    Petrov, RJ
    Rowe, RK
    Quigley, RM
    GEOTECHNICAL TESTING JOURNAL, 1997, 20 (01): : 49 - 62
  • [35] A comparison of sample preparation methodology in the evaluation of geosynthetic clay liner (GCL) hydraulic conductivity
    Siebken, JR
    Lucas, S
    TESTING AND ACCEPTANCE CRITERIA FOR GEOSYNTHETIC CLAY LINERS, 1997, 1308 : 45 - 52
  • [36] Hydraulic conductivity of bentonite-polymer composite geosynthetic clay liners permeated with bauxite liquor
    Li, Qin
    Chen, Jiannan
    Benson, Craig H.
    Peng, Daoping
    GEOTEXTILES AND GEOMEMBRANES, 2021, 49 (02) : 420 - 429
  • [37] Reductions in GCL Overlap Beneath an Exposed Geomembrane
    Brachman, Richard W. I.
    Rowe, R. Kerry
    Take, W. Andy
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2018, 144 (12)
  • [38] MEASUREMENTS OF CAPILLARY AND HYDRAULIC CONDUCTIVITY IN SALINE AND ADJACENT NONSALINE AREAS
    WIEGAND, CL
    HAISE, HR
    GARDNER, WR
    JOURNAL OF GEOPHYSICAL RESEARCH, 1962, 67 (09): : 3609 - +
  • [39] HYDRAULIC CONDUCTIVITY AND LEACHING OF AN ORGANIC SALINE-SODIC SOIL
    KOSMAS, C
    MOUSTAKAS, N
    GEODERMA, 1990, 46 (04) : 363 - 370
  • [40] Experimental results on hydraulic behaviour of a GCL
    Mazzieri, F
    Pasqualini, E
    FOURTEENTH INTERNATIONAL CONFERENCE ON SOIL MECHANICS AND FOUNDATION ENGINEERING, VOL 3, 1997, : 1919 - 1922