Extended depth of focus intraocular lens versus a new monofocal intraocular lens: A prospective comparative and interventional study

被引:0
|
作者
Sihmar, Yogika [1 ]
Singh, Basant K. [1 ]
Singh, Vinod K. [1 ]
Kumar, Santosh [1 ,3 ]
Chaudhary, Aparajita [1 ]
Saini, Sanchita [2 ]
机构
[1] MLN Med Coll, Dept Ophthalmol, Prayagraj, India
[2] King Georges Med Univ, Dept Ophthalmol, Lucknow, Uttar Pradesh, India
[3] MLN Med Coll, Dept Ophthalmol, Prayagraj, Uttar Pradesh, India
关键词
Contrast sensitivity; extended depth of focus intraocular lens; intermediate vision; Tecnis Eyhance; PERFORMANCE;
D O I
10.4103/sjopt.sjopt_68_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the visual outcome findings between a new monofocal intraocular lens (IOL) (Tecnis Eyhance) and extended depth of focus (EDOF) IOL (Appasamy Supraphob Infocus). METHODS: This prospective comparative interventional study evaluated 31 patients after implantation of Tecnis Eyhance (15 patients) and Supraphob EDOF IOL (16 patients). The uncorrected and corrected distance and intermediate and near visual acuity were measured at postoperative day 1, 1 week, 4 week, and 3 months. Contrast sensitivity, incidence of halos and glares, and patient satisfaction were assessed at 3 months postoperatively. RESULTS: The Tecnis Eyhance (n = 15) and Supraphob EDOF (n = 16) group were comparable with respect to all preoperative parameters including biometry, visual acuity, and cataract status. The average age distribution of participants was 56 +/- 6 years. Postoperatively, both groups had similar distance and intermediate vision, but the near vision was significantly better in the EDOF group (P < 0.01) as compared to Tecnis Eyhance at 3 months. The contrast sensitivity and patient satisfaction were similar in both the groups. The incidence of halos and glares was present in the EDOF group, but it was statistically insignificant. CONCLUSION: The Tecnis Eyhance and Supraphob EDOF both were effective in improving distance and intermediate vision, but the near vision was significantly better in the EDOF group. Both the groups retained good contrast sensitivity and the majority of patients were satisfied.
引用
收藏
页码:331 / 336
页数:6
相关论文
共 50 条
  • [41] Through-Focus Optical Bench Performance of Extended Depth-of-Focus and Bifocal Intraocular Lenses Compared to a Monofocal Lens
    Yoo, Young-Sik
    Whang, Woong-Joo
    Byun, Yong-Soo
    Piao, Jun Jie
    Kim, Dae Yu
    Joo, Choun-Ki
    Yoon, Geunyoung
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (04) : 236 - +
  • [42] Comparison Between an Intraocular Lens With Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens With Enhanced Intermediate Vision (Tecnis Eyhance ICB00)
    Jeon, Young Joon
    Yoon, Yisang
    Kim, Tae-im
    Koh, Kyungmin
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2021, 10 (06): : 542 - 547
  • [43] Comparative Study Between Non-Diffractive Extended Depth of Focus and Monofocal Intraocular Lenses
    Kandavel, Rom
    Colvard, Michael
    Dredge, Justin
    Bayle, Michael
    Alam, Tamanna
    Snyder, James
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1161 - 1168
  • [44] Visual performance of an extended depth of focus intraocular lens for treatment selection
    Thomas Kohnen
    Myriam Böhm
    Eva Hemkeppler
    Sabrina Schönbrunn
    Nina DeLorenzo
    Kerstin Petermann
    Michael Herzog
    Eye, 2019, 33 : 1556 - 1563
  • [45] Visual performance of an extended depth of focus intraocular lens for treatment selection
    Kohnen, Thomas
    Boehm, Myriam
    Hemkeppler, Eva
    Schoenbrunn, Sabrina
    DeLorenzo, Nina
    Petermann, Kerstin
    Herzog, Michael
    EYE, 2019, 33 (10) : 1556 - 1563
  • [46] POOLED RESULTS OF THE TECNIS SYMFONY EXTENDED DEPTH OF FOCUS INTRAOCULAR LENS
    Yin, C.
    Guzauskas, G. F.
    Wang, B. C. M.
    VALUE IN HEALTH, 2019, 22 : S363 - S363
  • [47] Functional results and photic phenomena with new extended-depth-of-focus intraocular Lens
    Bert C. Giers
    Ramin Khoramnia
    Dorottya Varadi
    Hannah Wallek
    Hyeck-Soo Son
    Mary S. Attia
    Gerd U. Auffarth
    BMC Ophthalmology, 19
  • [48] Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lens
    Alarcon, Aixa
    Carrasco, Antonio del Aguila
    Gounou, Franck
    Weeber, Henk
    Canovas, Carmen
    Piers, Patricia
    EYE, 2024, 38 (SUPPL 1) : 4 - 8
  • [49] Visual performance of a new Extended Depth of Focus (EDOF) intraocular lens: Preliminary results
    Moser Wurth, C. L.
    Lecumberri Lopez, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2022, 45 (05): : 529 - 536
  • [50] Functional results and photic phenomena with new extended-depth-of-focus intraocular Lens
    Giers, Bert C.
    Khoramnia, Ramin
    Varadi, Dorottya
    Wallek, Hannah
    Son, Hyeck-Soo
    Attia, Mary S.
    Auffarth, Gerd U.
    BMC OPHTHALMOLOGY, 2019, 19 (01)