Calibration Model Optimization for Strain Metrology of Equal Strength Beams Using Deflection Measurements

被引:6
|
作者
Yan, Yonggang [1 ]
Wu, Zhengxing [1 ,2 ]
Cui, Jianjun [2 ,3 ]
Chen, Kai [2 ]
Tang, Yanhong [3 ]
Yang, Ning [4 ]
机构
[1] Henan Polytech Univ, Sch Mech & Power Engn, Jiaozuo 454003, Peoples R China
[2] Natl Inst Metrol, Beijing 100029, Peoples R China
[3] Metrol & Testing Inst Tibet Autonomous Reg, Lhasa 850000, Peoples R China
[4] Shaanxi Inst Metrol Sci, Xian 710100, Peoples R China
关键词
metrology; calibration model; strain sensor; equal strength beam; deflection measurement; CANTILEVER BEAMS;
D O I
10.3390/s23063059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Strain sensors, especially fiber Bragg grating (FBG) sensors, are of great importance in structural health monitoring, mechanical property analysis, and so on. Their metrological accuracy is typically evaluated by equal strength beams. The traditional strain calibration model using the equal strength beams was built based on an approximation method by small deformation theory. However, its measurement accuracy would be decreased while the beams are under the large deformation condition or under high temperature environments. For this reason, an optimized strain calibration model is developed for equal strength beams based on the deflection method. By combining the structural parameters of a specific equal strength beam and finite element analysis method, a correction coefficient is introduced into the traditional model, and an accurate application-oriented optimization formula is obtained for specific projects. The determination method of optimal deflection measurement position is also presented to further improve the strain calibration accuracy by error analysis of the deflection measurement system. Strain calibration experiments of the equal strength beam were carried out, and the error introduced by the calibration device can be reduced from 10 mu epsilon to less than 1 mu epsilon. Experimental results show that the optimized strain calibration model and the optimum deflection measurement position can be employed successfully under large deformation conditions, and the deformation measurement accuracy is improved greatly. This study is helpful to effectively establish metrological traceability for strain sensors and furthermore improve the measurement accuracy of strain sensors in practical engineering scenarious.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] On the interest of using full field measurements in ductile damage model calibration
    Roux, E.
    Bouchard, P-O
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2015, 72 : 50 - 62
  • [42] TDR Calibration for Soil Moisture Measurements Using a Spectroscopic Dielectric Model
    Mironov, V. L.
    Kosolapova, L. G.
    Muzalevskiy, K. V.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 311 - 314
  • [43] Calibration of satellite measurements of river discharge using a global hydrology model
    Brakenridge, G. Robert
    Cohen, Sagy
    Kettner, Albert J.
    De Groeve, Tom
    Nghiem, Son V.
    Syvitski, James P. M.
    Fekete, Balazs M.
    JOURNAL OF HYDROLOGY, 2012, 475 : 123 - 136
  • [44] Calibration and application of a DSA Compact model for graphoepitaxy hole processes using contour-based metrology
    Fenger, Germain
    Burbine, Andrew
    Torres, J. Andres
    Ma, Yuansheng
    Granik, Yuri
    Krasnova, Polina
    Vandenberghe, Geert
    Gronheid, Roel
    Bekaert, Joost
    PHOTOMASK TECHNOLOGY 2014, 2014, 9235
  • [45] Prediction of shear strength of RC deep beams using XGBoost regression with Bayesian optimization
    Truong, Gia Toai
    Choi, Kyoung-Kyu
    Nguyen, Tri-Hai
    Kim, Chang-Soo
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2023, 27 (14) : 4046 - 4066
  • [46] Improved empirical model for the strut efficiency factor and the stiffness degradation coefficient for the strength and the deflection prediction of FRP RC deep beams
    Thomas, Job
    Ramadass, S.
    STRUCTURES, 2021, 29 : 2044 - 2066
  • [47] Prediction of Deflection of Shear-Critical RC Beams Using Compatibility-Aided Truss Model
    Kim, Sang-Woo
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [48] Calibration of testing equipment for reliable small-strain deformation measurements using synthetic specimens
    Kim, DS
    Kweon, GC
    GEOTECHNICAL TESTING JOURNAL, 2000, 23 (04): : 454 - 463
  • [49] On one approach to problem of processing of measurements using calibration signals based on multicriteria optimization
    Belov, Yu.A.
    Zavorotnyj, A.L.
    Kas'yanyuk, V.S.
    Problemy Upravleniya I Informatiki (Avtomatika), 2001, (05): : 5 - 13
  • [50] Macroscopic traffic flow model calibration using different optimization algorithms
    Anastasia Spiliopoulou
    Ioannis Papamichail
    Markos Papageorgiou
    Yannis Tyrinopoulos
    John Chrysoulakis
    Operational Research, 2017, 17 : 145 - 164