High efficiency multilayer coated laminar gratings with high line density for tender X-ray region

被引:5
|
作者
Wen, Shengyou [1 ,3 ,4 ]
Huang, Qiushi [1 ,3 ,4 ]
Sokolov, Andrey [2 ]
Zhuang, Yeqi [1 ,3 ,4 ]
Lemke, Stephanie [2 ]
Seliger, Tino [2 ]
Yu, Yue [1 ,3 ,4 ]
Viefhaus, Jens [2 ]
Qi, Runze [1 ,3 ,4 ]
Zhang, Zhong [1 ,3 ,4 ]
Wang, Zhanshan [1 ,3 ,4 ]
机构
[1] Tongji Univ, Sch Phys Sci & Engn, Inst Precis Opt Engn, Key Lab Adv Microstruct Mat MOE, Shanghai 200092, Peoples R China
[2] Helmholtz Zentrum Berlin Mat & Energie, BESSY 2, Albert Einstein Str 15, D-12489 Berlin, Germany
[3] Tongji Univ, Shanghai Profess Tech Serv Platform Full Spectrum, Shanghai 200092, Peoples R China
[4] Tongji Univ, Shanghai Frontiers Sci Ctr Digital Opt, Shanghai 200092, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Multilayer coated laminar grating; Tender X-ray; Diffraction grating; DIFFRACTION EFFICIENCY; BLAZED GRATINGS; MONOCHROMATORS; SYNCHROTRON; RESOLUTION;
D O I
10.1016/j.optlastec.2023.109979
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Driven by the demand of high efficiency and high resolution monochromators and spectrometers in the tender Xray range, high line density multilayer coated laminar gratings (MLLG) were designed, manufactured, and analyzed. Theoretical simulations displayed that a 5000 l/mm MLLG could realize high resolution at 3 keV and 40 times higher diffraction efficiency than the single-layer coated grating. For the first demonstration of the high line density MLLGs, two 3000 l/mm laminar gratings were fabricated and coated by Cr/C multilayers with different periodic thicknesses to achieve high efficiency (HE) and high resolution (HR) performance. For MLLGHE, a maximum efficiency of 54.5% was achieved at 4.4 keV. For MLLG-HR, relatively high efficiency of 23.1%- 38.6% were demonstrated with much stronger asymmetric diffraction in 2-4 keV, which can significantly increase the energy resolution of the system.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] X-ray reflection by multilayer surface gratings
    Mikulik, P
    Baumbach, T
    PHYSICA B, 1998, 248 : 381 - 386
  • [32] High-efficiency blazed transmission gratings for high-resolution soft x-ray spectroscopy
    Heilmann, Ralf K.
    Bruccoleri, Alexander R.
    Schattenburg, Mark L.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY VII, 2015, 9603
  • [33] High resolution multilayer x-ray optics
    Morawe, C
    Peffen, JC
    Ziegler, E
    Freund, AK
    ADVANCES IN X-RAY OPTICS, 2001, 4145 : 61 - 71
  • [34] Multilayer-coated soft x-ray diffraction gratings for synchrotron radiation applications
    Kleineberg, U
    Stock, HJ
    Menke, D
    Wehmeyer, O
    Heinzmann, U
    GRATINGS AND GRATING MONOCHROMATORS FOR SYNCHROTRON RADIATION, 1997, 3150 : 18 - 30
  • [35] Breaking the efficiency limit for high-frequency blazed multilayer soft x-ray gratings: Conical vs classical diffraction
    Goray, L. I.
    Egorov, A. Yu.
    APPLIED PHYSICS LETTERS, 2016, 109 (10) : 201 - 204
  • [36] MULTILAYER GRATINGS FOR THE SOFT-X-RAY REGION
    ANDRE, JM
    SAMMAR, A
    MALEK, CK
    TROUSSEL, P
    BAC, S
    BARCHEWITZ, R
    PARDO, B
    BERROUANE, H
    MORENO, T
    LADAN, FR
    RIVOIRA, R
    SCHIRMANN, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1399 - 1403
  • [37] FABRICATION AND PERFORMANCE OF MULTILAYER COATED LAMINAR PHASE GRATING IN THE SOFT-X-RAY REGION
    YUAN, LX
    FAN, ZX
    FU, SJ
    CUI, MQ
    PHYSICA SCRIPTA, 1995, 51 (06): : 680 - 682
  • [38] DIFFRACTION OF MULTILAYER GRATINGS AND ZONE PLATES IN THE X-RAY REGION USING THE BORN APPROXIMATION
    SAMMAR, A
    ANDRE, JM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (04): : 600 - 613
  • [39] FABRICATION PROCESS FOR MULTILAYER X-RAY PHASE GRATINGS
    ROSS, TS
    PERKINS, RT
    KNIGHT, LV
    OPTICAL ENGINEERING, 1990, 29 (07) : 728 - 732
  • [40] X-RAY TESTS OF MULTILAYER COATED OPTICS
    GOLUB, L
    SPILLER, E
    BARTLETT, RJ
    HOCKADAY, MP
    KANIA, DR
    TRELA, WJ
    TATCHYN, R
    APPLIED OPTICS, 1984, 23 (20): : 3529 - 3533