Development and Evaluation of the Magnetic Properties of a New Manganese (II) Complex: A Potential MRI Contrast Agent

被引:9
|
作者
Reale, Giovanni [1 ]
Calderoni, Francesca [2 ]
Ghirardi, Teresa [3 ]
Porto, Francesca [4 ]
Illuminati, Federica [5 ]
Marvelli, Lorenza [4 ]
Martini, Petra [6 ]
Uccelli, Licia [1 ]
Tonini, Eugenia [2 ]
Del Bianco, Lucia [7 ]
Spizzo, Federico [7 ]
Capozza, Martina [8 ]
Cazzola, Emiliano [9 ]
Carnevale, Aldo [1 ]
Giganti, Melchiore [1 ]
Turra, Alessandro [2 ]
Esposito, Juan [3 ]
Boschi, Alessandra [4 ]
机构
[1] Univ Ferrara, Dept Translat Med, I-44121 Ferrara, Italy
[2] Univ Hosp Ferrara, Med Phys Unit, I-44124 Cona, Italy
[3] Natl Inst Nucl Phys, Legnaro Natl Labs LNL, INFN, I-35020 Padua, Italy
[4] Univ Ferrara, Dept Chem Pharmaceut & Agr Sci, I-44121 Ferrara, Italy
[5] Univ Hosp Ferrara, Radiol Unit, I-44124 Cona, Italy
[6] Univ Ferrara, Dept Environm & Prevent Sci, I-44121 Ferrara, Italy
[7] Univ Ferrara, Dept Phys & Earth Sci, I-44122 Ferrara, Italy
[8] Univ Torino, Dept Mol Biotechnol & Hlth Sci, I-10126 Turin, Italy
[9] IRCCS Sacro Cuore Don Calabria Hosp, I-37024 Negrar, Italy
关键词
magnetic resonance imaging; manganese; dithiocarbamates; NEPHROGENIC SYSTEMIC FIBROSIS; GADOLINIUM DEPOSITION; RADIOLOGISTS;
D O I
10.3390/ijms24043461
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Magnetic resonance imaging (MRI) is a non-invasive powerful modern clinical technique that is extensively used for the high-resolution imaging of soft tissues. To obtain high-definition pictures of tissues or of the whole organism this technique is enhanced by the use of contrast agents. Gadolinium-based contrast agents have an excellent safety profile. However, over the last two decades, some specific concerns have surfaced. Mn(II) has different favorable physicochemical characteristics and a good toxicity profile, which makes it a good alternative to the Gd(III)-based MRI contrast agents currently used in clinics. Mn(II)-disubstituted symmetrical complexes containing dithiocarbamates ligands were prepared under a nitrogen atmosphere. The magnetic measurements on Mn complexes were carried out with MRI phantom measurements at 1.5 T with a clinical magnetic resonance. Relaxivity values, contrast, and stability were evaluated by appropriate sequences. Studies conducted to evaluate the properties of paramagnetic imaging in water using a clinical magnetic resonance showed that the contrast, produced by the complex [Mn(II)(L')(2)] x 2H(2)O (L' = 1.4-dioxa-8-azaspiro[4.5]decane-8-carbodithioate), is comparable to that produced by gadolinium complexes currently used in medicine as a paramagnetic contrast agent.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Mn(II) Complex of Lipophilic Group-Modified Ethylenediaminetetraacetic Acid (EDTA) as a New Hepatobiliary MRI Contrast Agent
    Chen, Keyu
    Li, Pan
    Zhu, Chunrong
    Xia, Zhiyang
    Xia, Qian
    Zhong, Lei
    Xiao, Bin
    Cheng, Tao
    Wu, Changqiang
    Shen, Chengyi
    Zhang, Xiaoming
    Zhu, Jiang
    JOURNAL OF MEDICINAL CHEMISTRY, 2021, 64 (13) : 9182 - 9192
  • [42] A New Bis(aquated) High Relaxivity Mn(II) Complex as an Alternative to Gd(III)-Based MRI Contrast Agent
    Phukan, Bedika
    Mukherjee, Chandan
    Goswami, Upashi
    Sarmah, Amrit
    Mukherjee, Subhajit
    Sahoo, Suban K.
    Moi, Sankar Ch.
    INORGANIC CHEMISTRY, 2018, 57 (05) : 2631 - 2638
  • [43] Manganese (II) Complex of 1,4,7-Triazacyclononane-1,4,7-Triacetic Acid (NOTA) as a Hepatobiliary MRI Contrast Agent
    Islam, Md. Kamrul
    Baek, Ah-Rum
    Yang, Byeong-Woo
    Kim, Soyeon
    Hwang, Dong Wook
    Nam, Sung-Wook
    Lee, Gang-Ho
    Chang, Yongmin
    PHARMACEUTICALS, 2023, 16 (04)
  • [44] MRI MEASUREMENT OF HEPATOCYTE TOXICITY USING THE NEW MRI CONTRAST AGENT MANGANESE DIPYRIDOXAL DIPHOSPHATE, A MANGANESE PYRIDOXAL 5-PHOSPHATE CHELATE
    YOUNG, SW
    SIMPSON, BB
    RATNER, AV
    MATKIN, C
    CARTER, EA
    MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (01) : 1 - 13
  • [45] Development of a paraCEST and Fluorine MRI Contrast Agent
    Ernotte, P.
    Laurent, S.
    Henoumont, C.
    INVESTIGATIVE RADIOLOGY, 2019, 54 (12) : 807 - 808
  • [46] PHARMACEUTICAL PROPERTIES, BIODISTRIBUTION, AND IMAGING CHARACTERISTICS OF MANGANESE-MESOPORPHYRIN - A POTENTIAL HEPATOBILIARY CONTRAST AGENT FOR MAGNETIC-RESONANCE-IMAGING
    SCHMIEDL, UP
    NELSON, JA
    ROBINSON, DH
    MICHALSON, A
    STARR, F
    FRENZEL, T
    EBERT, W
    SCHUMANNGIAMPIERI, G
    INVESTIGATIVE RADIOLOGY, 1993, 28 (10) : 925 - 932
  • [47] VSION as high field MRI T1 contrast agent: evidence of their potential as positive contrast agent for magnetic resonance angiography
    Vangijzegem, T.
    Stanicki, D.
    Boutry, S.
    Paternoster, Q.
    Vander Elst, L.
    Muller, R. N.
    Laurent, S.
    NANOTECHNOLOGY, 2018, 29 (26)
  • [48] Preparation and characterization of magnetic theranostic nanoparticles for curcumin delivery and evaluation as MRI contrast agent
    Nosrati, Hamed
    Charmi, Jalil
    Abedini, Somayeh
    Rashidi, Nafis
    Attari, Elahe
    Davaran, Soodabeh
    Danafar, Hossein
    Manjili, Hamidreza Kheiri
    APPLIED ORGANOMETALLIC CHEMISTRY, 2018, 32 (12)
  • [49] Synthesis and in vitro and in vivo evaluation of manganese(III) porphyrin-dextran as a novel MRI contrast agent
    Zhang, Zhi
    He, Rui
    Yan, Kun
    Guo, Qian-ni
    Lu, Yun-guo
    Wang, Xu-xia
    Lei, Hao
    Li, Zao-ying
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2009, 19 (23) : 6675 - 6678
  • [50] Synthesis, Characterization and Magnetic Properties of a New Manganese(II) Phosphite
    Zhang Hua
    Wang Li-ping
    Shi Su-hua
    Huang Liang-liang
    Wang Li
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (04) : 563 - 566