Enhancing frequency regulation in multi-area interconnected MPS with virtual inertia using MPC plus PIDN controller

被引:1
|
作者
Vidyarthi, Prabhat Kumar [1 ,2 ]
Kumar, Ashiwani [1 ]
机构
[1] Natl Inst Technol Patna, Dept Elect Engn, Patna, India
[2] Natl Inst Technol Patna, Dept Elect Engn, Patna 800005, India
来源
关键词
automatic generation control (AGC); model predictive control (MPC) controller; modified IEEE-39; opposition-based sea-horse optimization (OSHO); renewable energy sources (RESs); virtual inertia (VI); POWER-SYSTEM; ENERGY-STORAGE;
D O I
10.1002/oca.3121
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The challenge of controlling frequency deviation becomes more difficult as the complexity of a power network increases. The robustness of the controller has a major impact on the stability of a Modern Power system (MPS). Due to the hybridization of MPS basic AGC controllers (PID, FOPID, and TID) are insufficient to give optimal performance of a plant. This requires a robust controller. So, a novel MPC + PIDN controller has been proposed and evaluated by comparing it with several existing controllers, which gives optimal performance in terms of overshoot, undershoot, and settling time. A new modified Opposition-based Sea-horse Optimization (OSHO) method has been suggested to optimize the various controller settings. To demonstrate the OSHO's superiority, it is compared with a few popular, existing meta-heuristic optimizations. The higher penetration levels of RESs reduced system inertia which further deteriorate frequency response in MPS. To overcome these challenges virtual inertia (VI) is implemented with MPC. VI is applied to improve the performance of the AGC of the interconnected MPS along with emphasizing the nature of intermittent renewable energy sources (RESs) of PV and wind energy. To determine the reliability and flexibility of the proposed controller, analysis has been done under a different situation, including step, random disturbances, and modified IEEE-39 bus. Finally, the stability analysis is performed on a bode plot and the proposed results are compared with previously published literature. The extensive study demonstrates strong evidence that the suggested control approach is efficient and effective.
引用
收藏
页码:1750 / 1773
页数:24
相关论文
共 50 条
  • [21] Ant lion optimized hybrid intelligent PID-based sliding mode controller for frequency regulation of interconnected multi-area power systems
    Haroun, Gomaa A. H.
    Li, Yin-Ya
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2020, 42 (09) : 1594 - 1617
  • [22] Analysis of derivative control based virtual inertia in multi-area high-voltage direct current interconnected power systems
    Rakhshani, Elyas
    Remon, Daniel
    Mir Cantarellas, Antoni
    Rodriguez, Pedro
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (06) : 1458 - 1469
  • [23] Influence of the DC frequency limit controller on the frequency characteristics of the multi-area asynchronous interconnected power grid with renewable energy integration
    Liu, Bicheng
    Xiao, Huangqing
    Yang, Ping
    Cai, Zexiang
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [24] Robust Load Frequency Control of Multi-Area Interconnected system Including SMES units Using Type-2 Fuzzy Controller
    Santhi, R. Vijaya
    Sudha, K. R.
    Devi, S. Prameela
    2013 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ - IEEE 2013), 2013,
  • [25] Multi-area Load Frequency Control using IP controller tuned by Tabu Search
    Shirvani, Mojtaba
    Abdollahi, Mostafa
    Memaripour, Ahmad
    Behzadipour, Elahe
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (08): : 244 - 248
  • [26] Frequency Control of Modern Multi-Area Power Systems Using Fuzzy Logic Controller
    Aluko, Anuoluwapo O.
    Dorrell, David G.
    Pillay-Carpanen, R.
    Ojo, Evans E.
    2019 IEEE PES/IAS POWERAFRICA, 2019, : 645 - 649
  • [27] Designing of robust frequency stabilization using optimized MPC-(1+PIDN) controller for high order interconnected renewable energy based power systems
    Gulzar, Muhammad Majid
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
  • [28] Frequency stabilization of multi-area multi-source interconnected power system using TCSC and SMES mechanism
    Nandi, M.
    Shiva, C. K.
    Mukherjee, V.
    JOURNAL OF ENERGY STORAGE, 2017, 14 : 348 - 362
  • [29] Design and analysis of tilt integral derivative controller with filter for load frequency control of multi-area interconnected power systems
    Sahu, Rabindra Kumar
    Panda, Sidhartha
    Biswal, Ashutosh
    Sekhar, G. T. Chandra
    ISA TRANSACTIONS, 2016, 61 : 251 - 264
  • [30] Pelican Optimization Algorithm-Based Proportional-Integral-Derivative Controller for Superior Frequency Regulation in Interconnected Multi-Area Power Generating System
    Sagor, Abidur Rahman
    Abu Talha, Md
    Ahmad, Shameem
    Ahmed, Tofael
    Alam, Mohammad Rafiqul
    Hazari, Md. Rifat
    Shafiullah, G. M.
    ENERGIES, 2024, 17 (13)