Monte Carlo Evaluation of Uncertainties of UV Spectra Measured With Brewer Spectroradiometers

被引:2
|
作者
Gonzalez, C. [1 ,2 ]
Vilaplana, J. M. [1 ]
Serrano, A. [2 ]
机构
[1] Inst Nacl Tecn Aeroespacial INTA, Area Invest & Instrumentac Atmosfer, Huelva, Spain
[2] Univ Extremadura, Fac Ciencias, Dept Fis, Inst Agua Cambio Climat & Sostenibil, Badajoz, Spain
关键词
Monte Carlo; Brewer spectrometer; UV irradiance; UV uncertainty; SOLAR ULTRAVIOLET IRRADIANCE; MONITORING INSTRUMENT OMI; EL ARENOSILLO SPAIN; TOTAL OZONE; TEMPERATURE-DEPENDENCE; QUALITY-ASSURANCE; REFERENCE PLANE; OPTICAL DEPTH; RADIATION; TRENDS;
D O I
10.1029/2023JD039500
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Precise spectral ultraviolet (UV) measurements are needed to ensure human protection as well as to support scientific research. Quantifying the uncertainty of the UV spectra recorded is crucial to evaluate the quality of the measurements which is needed, in turn, for the assessment of their reliability. However, for double-monochromator spectroradiometers, the analytical derivation of this uncertainty is a challenging task due to the difficulties involved in propagating individual uncertainties. Under these circumstances, a Monte Carlo simulation is a reliable alternative as it does not require the calculation of partial derivatives and considers both nonlinear effects and correlations in the data. In the present study, the uncertainty of the spectral UV irradiance measured by a Brewer MKIII spectrophotometer is evaluated using a Monte Carlo approach. This instrument belongs to the National Institute of Aerospace Technology and has successfully participated in several international campaigns, which ensures its precise calibration. The average expanded uncertainty (k = 2) of the global UV irradiance measured by this instrument varies between 10% at 300 nm and 7% at 363 nm. At shorter wavelengths, it increases sharply due to thermal and electronic noise as well as wavelength misalignment. The results indicate that a Brewer spectrophotometer is suitable for climatological studies and model validation. Nevertheless, a substantial reduction of these uncertainties might be required for accurately detecting long-term UV trends. Although the study focused on a Brewer spectrometer, the methodology used for the uncertainty analysis is general and can be adapted to most UV spectroradiometers. The solar ultraviolet (UV) spectrum covers the wavelength range from 100 to 400 nm. Although it represents less than 10% of the total radiation reaching the earth's surface, it is of great importance as it can be harmful to humans, aquatic, and terrestrial ecosystems. To study its effects, high-quality measurements are needed. To determine the quality of the irradiance recorded its uncertainty must be first evaluated. Most techniques used for uncertainty estimation rely on the calculation of partial derivatives, which are difficult to obtain for most instruments measuring UV irradiance. The reason for this is that the mathematical expression relating some uncertainty sources and the measured irradiance is complex, with unknown correlations between the different uncertainty sources. To solve this problem, the Monte Carlo technique was used instead of the analytical one. The Monte Carlo approach is easier to implement and needs no calculation of partial derivatives. The method was implemented for a Brewer spectrometer, one of the preferred devices to measure UV irradiance. The results indicate that the Brewer is suitable for model validation, but a substantial reduction of its uncertainty might be needed to accurately detect spectral UV trends. A Monte Carlo technique has been implemented to obtain the uncertainty of the spectral ultraviolet recorded by a Brewer MKIII spectrometerThe methodology used for the uncertainty propagation is general and can be adapted to most spectroradiometers used in ultraviolet (UV) researchBrewer spectrometers are suitable for model and satellite validation but might be limited in the determination of spectral UV trends
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Monte Carlo evaluation of uncertainties in photon and electron TG-51 absorbed dose calibration
    Mcdermott, Patrick
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [42] MONTE-CARLO APPROACH TO CORE-WIDE PROBABILISTIC EVALUATION OF TEMPERATURE UNCERTAINTIES IN LMFBRS
    MIKI, K
    INOUE, K
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 22 (NOV16): : 286 - 286
  • [43] UV-filtered fermionic Monte Carlo
    de Forcrand, P
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 73 : 822 - 824
  • [44] Direct simulation Monte Carlo dissociation model evaluation: Comparison to measured cross sections
    Wysong, Ingrid J.
    Dressler, Rainer A.
    Chiu, Y.H.
    Boyd, Iain D.
    2002, American Inst. Aeronautics and Astronautics Inc. (16)
  • [45] Direct simulation Monte Carlo dissociation model evaluation: comparison to measured cross sections
    Wysong, IJ
    Dressler, RA
    Chiu, YH
    Boyd, ID
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2002, 16 (01) : 83 - 93
  • [46] INVESTIGATION OF ENERGY RESPONSE OF GERMANIUM DETECTORS AND CORRECTION OF MEASURED SPECTRA BY MEANS OF MONTE-CARLO SIMULATION
    CHAN, HP
    CHEN, CT
    DOI, K
    FEWELL, TR
    SHUPING, RE
    MEDICAL PHYSICS, 1982, 9 (04) : 633 - 633
  • [47] INVESTIGATION OF ENERGY RESPONSES OF GERMANIUM DETECTORS AND CORRECTION OF MEASURED SPECTRA BY MEANS OF MONTE-CARLO SIMULATION
    CHAN, HP
    CHEN, CT
    DOI, K
    FEWELL, TR
    SHUPING, RE
    RADIATION RESEARCH, 1984, 99 (03) : 443 - 464
  • [48] Off-axis x-ray spectra: A comparison of Monte Carlo simulated and computed x-ray spectra with measured spectra
    Bhat, M
    Pattison, J
    Bibbo, G
    Caon, M
    MEDICAL PHYSICS, 1999, 26 (02) : 303 - 309
  • [49] Kinetic Monte Carlo Simulation of DNMR Spectra
    Szalay, Zsofia
    Rohonczy, Janos
    ANNUAL REPORTS ON NMR SPECTROSCOPY, VOL 73, 2011, 73 : 175 - 215
  • [50] MONTE-CARLO UNFOLDING OF NEUTRON SPECTRA
    SANNA, R
    OBRIEN, K
    NUCLEAR INSTRUMENTS & METHODS, 1971, 91 (04): : 573 - &