Effect of ascending aorta replacement on the long-term outcomes of bicuspid aortic valve repair

被引:1
|
作者
Svensson, Lars G. [1 ,3 ,6 ]
Rosinski, Brad F. [1 ,4 ]
Miletic, Kyle [1 ,4 ]
Hodges, Kevin [4 ]
Rajeswaran, Jeevanantham [5 ]
Griffin, Brian [3 ]
Desai, Milind Y. [2 ,3 ]
Kalahasti, Vidyasagar [3 ]
Goff, Zackary [4 ]
Johnston, Douglas R. [1 ,3 ]
Vargo, Patrick R. [1 ,3 ]
Roselli, Eric E. [1 ,3 ]
Blackstone, Eugene H. [1 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Dept Thorac & Cardiovasc Surg, Cleveland, OH USA
[2] Cleveland Clin, Lerner Res Inst, Cardiovasc Med Heart Vasc & Thorac Inst, Cleveland, OH USA
[3] Cleveland Clin, Lerner Res Inst, Aorta Ctr, Cleveland, OH USA
[4] Cleveland Clin, Lerner Res Inst, Educ Inst, Cleveland, OH USA
[5] Cleveland Clin, Lerner Res Inst, Dept Quantitat Hlth Sci, Cleveland, OH USA
[6] Cleveland Clin, Heart Vasc & Thorac Inst, 9500 Euclid Ave,Desk J1-227, Cleveland, OH 44195 USA
来源
关键词
aneurysm; aortic valve regurgitation; connec-tive tissue disorder; reoperation; survival; REIMPLANTATION; DURABILITY; DECOMPOSITION;
D O I
10.1016/j.jtcvs.2023.02.024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The study objective was to determine the effect of sinutubular junction stabilization on long-term outcomes of bicuspid aortic valve repair.Methods: From January 1998 to January 2020, 419 patients underwent bicuspid aortic valve repair with ascending aorta replacement and 421 without (bicuspid aortic valve repair alone). Propensity score matching (97 pairs) was used to compare outcomes. Results: Before matching, prevalence of severe aortic regurgitation at 10 years was 5.4% after bicuspid aortic valve repair + ascending aorta replacement and 10% after bicuspid aortic valve repair alone; aortic valve gradient was 20 mm Hg after bicuspid aortic valve repair + ascending aorta replacement and 19 mm Hg after bicuspid aortic valve repair alone. Ten-year freedom from reoperation overall was 79% after bicuspid aortic valve repair + ascending aorta replacement and 75% after bicuspid aortic valve repair alone; freedom from late aortic regurgitation was 93% after bicuspid aortic valve repair + ascending aorta replacement and 92% after bicuspid aortic valve repair alone; and freedom from aortic stenosis was 87% after bicuspid aortic valve repair + ascending aorta replacement and 93% after bicuspid aortic valve repair alone. Ten-year survival was 95% after bicuspid aortic valve repair + ascending aorta replacement and 96% after bicuspid aortic valve repair alone. After matching, prevalence of severe aortic regurgitation at 10 years was 11% after bicuspid aortic valve repair + ascending aorta replacement and 9.1% after bicuspid aortic valve repair alone (P = .33); aortic valve gradient was 16 mm Hg after bicuspid aortic valve repair + ascending aorta replacement and 25 mm Hg after bicuspid aortic valve repair alone (P<.0001). Ten-year freedom from reoperation was 85% after bicuspid aortic valve repair + ascending aorta replacement and 72% after bicuspid aortic valve repair alone (P = .08) overall. Ten-year freedom from reoperation for late aortic regurgitation was 88% after bicuspid aortic valve repair + ascending aorta replacement and 86% after bicuspid aortic valve repair alone (P = .65). Freedom from aortic stenosis was 97% after bicuspid aortic valve repair + ascending aorta replacement and 91% after bicuspid aortic valve repair alone (P = .03). Ten-year survival was 96% after bicuspid aortic valve repair + ascending aorta replacement and 96% after bicuspid aortic valve repair alone (P = .16).Conclusions: Bicuspid aortic valve repair with or without ascending aorta replacement is associated with good short-and long-term outcomes. Bicuspid aortic valve repair + ascending aorta replacement has a minimal effect on long-term repair durability. Sinutubular junction stabilization should not be performed for the sole purpose of long-term repair durability.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Effect of transcatheter aortic valve replacement on ascending aorta dilatation rate in patients with tricuspid and bicuspid aortic stenosis
    Zheng, Hua-Jie
    Cheng, Yong -Bo
    Lin, De-Qing
    Yan, Chao-Jun
    Yu, San-Jiu
    He, Ping
    Li, Jun
    Cheng, Wei
    IJC HEART & VASCULATURE, 2023, 49
  • [32] LONG-TERM FOLLOW-UP AFTER SEPARATE REPLACEMENT OF THE AORTIC-VALVE AND ASCENDING AORTA
    KARCK, M
    LAAS, J
    HEINEMANN, M
    BORST, HG
    HERZ, 1992, 17 (06) : 394 - 397
  • [33] Congenital bicuspid aortic valve and an aneurysm of the ascending aorta
    Olearchyk, AS
    JOURNAL OF CARDIAC SURGERY, 2004, 19 (05) : 462 - 463
  • [34] Surgical approach to ascending aorta in bicuspid aortic valve
    Kuralay, E
    Özal, E
    Cingöz, F
    Ceylan, S
    Tatar, H
    JOURNAL OF CARDIAC SURGERY, 2003, 18 (02) : 173 - 180
  • [35] Progression of the ascending aorta diameter after surgical or transcatheter bicuspid aortic valve replacement
    Chiariello, Giovanni Alfonso
    Di Mauro, Michele
    Pasquini, Annalisa
    Bruno, Piergiorgio
    Nesta, Marialisa
    Fabiani, Ludovica
    Mazza, Andrea
    Meloni, Martina
    Baldo, Elisabetta
    Ponzo, Myriana
    Ferraro, Francesco
    Conserva, Antonio Davide
    D'Acierno, Edoardo
    Villa, Emmanuel
    Trani, Carlo
    Burzotta, Francesco
    Massetti, Massimo
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 38 (05):
  • [36] Ascending Aorta Dilation is Less Frequent in Bicuspid Aortic Valve With Coarctation of Aorta Compared to Isolated Bicuspid Aortic Valve
    Shikhare, Anuja
    Hassan, Moeez
    Coffey, Mary
    Rangel, Ismael Gonzalez
    CIRCULATION, 2021, 144
  • [37] Should the dilated ascending aorta be repaired at the time of bicuspid aortic valve replacement?aEuro
    Kaneko, Tsuyoshi
    Shekar, Prem
    Ivkovic, Vladimir
    Longford, Nicholas T.
    Huang, Chuan-Chin
    Sigurdsson, Martin I.
    Neely, Robert C.
    Yammine, Maroun
    Ejiofor, Julius I.
    Vieira, Vanessa Montiero
    Shahram, Jasmine T.
    Habchi, Karam M.
    Malzberg, Gregory W.
    Martin, Peter S.
    Bloom, Jordan
    Isselbacher, Eric M.
    Muehlschlegel, J. Daniel
    Sundt, Thoralf M., III
    Body, Simon C.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (03) : 560 - 568
  • [38] Ascending thoracic aorta aneurysm repair induces positive hemodynamic outcomes in a patient with unchanged bicuspid aortic valve
    Condemi, Francesca
    Campisi, Salvatore
    Viallon, Magalie
    Croisille, Pierre
    Fuzelier, Jean-Francois
    Avril, Stephane
    JOURNAL OF BIOMECHANICS, 2018, 81 : 145 - 148
  • [39] Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve
    Aicher, Diana
    Kunihara, Takashi
    Abou Issa, Omar
    Brittner, Brigitte
    Graeber, Stefan
    Schaefers, Hans-Joachim
    CIRCULATION, 2011, 123 (02) : 178 - 185
  • [40] Valve Configuration Determines Long-term Results After Repair of the Bicuspid Aortic Valve
    Aicher, Diana
    Kunihara, Takashi
    Abou Issar, Omar
    Bierbach, Benjamin
    Schaefers, Hans-Joachim
    CIRCULATION, 2009, 120 (18) : S724 - S724