Underestimation of Occupational Radiation Exposure During Endovascular Abdominal Aortic Aneurysm Repair

被引:1
|
作者
Chiang, Hsien-Wen [1 ]
Chuang, Tzu-Chao [1 ]
Chen, Tou-Rong [2 ,3 ,4 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung, Taiwan
[2] Chung Shan Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[3] Chung Shan Med Univ Hosp, Dept Med Imaging, Taichung, Taiwan
[4] Chung Shan Med Univ, Dept Med Imaging & Radiol Sci, 110,Sec 1,Jianguo N Rd, Taichung 402, Taiwan
来源
HEALTH PHYSICS | 2024年 / 126卷 / 01期
关键词
operational topics; exposure; occupational; fluoroscopy; x rays; ACTIVE PERSONAL DOSIMETERS; INTERVENTIONAL RADIOLOGY; PERFORMANCE;
D O I
10.1097/HP.0000000000001744
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During interventional procedures of endovascular abdominal aortic aneurysm repair (EVAR), the dosimeter was conventionally placed on chest facing toward the surgical table, instead of the main source of scatter radiation. Purpose of this study is to evaluate the underestimation of occupational radiation exposure. Phantom experiments were performed in a hybrid operating room equipped with an interventional angiography system. Electric personal dosimeters were placed at the level of eyes, chest, abdomen, and gonad of three positions, representing the principal operator (PO), assistant operator (AO), and sterile nurse (SN). Personal dose equivalent was measured with two different orientations of radiation detection, facing the table and facing the phantom, respectively. In addition to fluoroscopy, the dose produced by digital subtraction angiography was also measured to estimate the radiation exposure of routine EVAR. In this study, staff doses of 26 EVAR cases were also collected in our hospital to correlate the estimated dose. Our results show that the facing-phantom dose normalized by dose area product of patient is significantly higher than the facing-table dose when the latter is regularly seen in clinical practice. This underestimation could be even worse at a more distant position (e.g., AO and SN) as the incident angle of scatter radiation is larger. Besides, the estimated dose is highly correlated with the on-site measured dose (R-2 similar to 0.8) at chest and gonad of the PO.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 50 条
  • [21] Analysis of Radiation Exposure During Endovascular Aneurysm Repair
    Butler, Michael
    Patel, Madhukar S.
    Wilson, Samuel E.
    AMERICAN SURGEON, 2012, 78 (10) : 1029 - 1032
  • [22] Occupational Radiation Exposure During Endovascular Aortic Procedures
    Patel, A. P.
    Gallacher, D.
    Dourado, R.
    Lyons, O.
    Smith, A.
    Zayed, H.
    Waltham, M.
    Sabharwal, T.
    Bell, R.
    Carrell, T.
    Taylor, P.
    Modarai, B.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (04) : 424 - 430
  • [23] Radiation exposure in endovascular repair of abdominal and thoracic aortic aneurysms
    Monastiriotis, Spyridon
    Comito, Matthew
    Labropoulos, Nicos
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) : 753 - 761
  • [24] Direct and Indirect Measurement of Patient Radiation Exposure during Endovascular Aortic Aneurysm Repair
    Weiss, Dustin J.
    Pipinos, Iraklis I.
    Longo, G. Mathew
    Lynch, Thomas G.
    Rutar, Frank J.
    Johanning, Jason M.
    ANNALS OF VASCULAR SURGERY, 2008, 22 (06) : 723 - 729
  • [25] The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair
    Fossaceca, Rita
    Brambilla, Marco
    Guzzardi, Giuseppe
    Cerini, Paolo
    Renghi, Alessandra
    Valzano, Serena
    Brustia, Piero
    Carriero, Alessandro
    EUROPEAN RADIOLOGY, 2012, 22 (11) : 2424 - 2431
  • [26] The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair
    Rita Fossaceca
    Marco Brambilla
    Giuseppe Guzzardi
    Paolo Cerini
    Alessandra Renghi
    Serena Valzano
    Piero Brustia
    Alessandro Carriero
    European Radiology, 2012, 22 : 2424 - 2431
  • [27] Radiation burden of patients undergoing endovascular abdominal aortic aneurysm repair
    Kalef-Ezra, John A.
    Karavasilis, Stratos
    Ziogas, Dimosthenis
    Dristiliaris, Dimitris
    Michalis, Lampros K.
    Matsagas, Miltiadis
    JOURNAL OF VASCULAR SURGERY, 2009, 49 (02) : 283 - 287
  • [28] Endovascular Abdominal Aortic Aneurysm Repair: Patient Dose and Radiation Risks
    Geleijns, J.
    Koning, O.
    van Bockel, H.
    MEDICAL PHYSICS, 2009, 36 (06) : 2474 - +
  • [29] Endovascular repair of the ruptured abdominal aortic aneurysm
    Norgren, Lars
    Larzon, Thomas
    VASCULAR MEDICINE, 2008, 13 (01) : 45 - 46
  • [30] Fenestrated Endovascular Abdominal Aortic Aneurysm Repair
    Pena, Constantino S.
    Schiro, Brian J.
    Benenati, James F.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 21 (03) : 156 - 164