Validity and reliability of an app-based medical device to empower individuals in evaluating their physical capacities

被引:2
|
作者
Mazeas, Alexandre [1 ,2 ,3 ]
Blond, Marine [3 ]
Chalabaev, Aina [1 ]
Duclos, Martine [2 ,4 ]
机构
[1] Univ Grenoble Alpes, SENS, Grenoble, France
[2] Clermont Auvergne Univ, INRAE, UNH, CRNH Auvergne, Clermont Ferrand, France
[3] Kiplin, Nantes, France
[4] Univ Hosp Clermont Ferrand, Hosp G Montpied, Dept Sport Med & Funct Explorat, Clermont Ferrand, France
来源
PLOS ONE | 2023年 / 18卷 / 08期
关键词
6-MINUTE WALK TEST; CHAIR-STAND TEST; EXERCISE CAPACITY; OLDER-ADULTS; STRENGTH; REPRODUCIBILITY; PERFORMANCE; MORTALITY; EQUATIONS; STATEMENT;
D O I
10.1371/journal.pone.0289874
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
BackgroundCardiorespiratory fitness and muscle strength are valid markers of health and strong predictors of mortality and morbidity. The tests used to measure these variables require in-person visits with specialized equipment and trained personnel-leading to organizational constraints both for patients and hospitals, and making them difficult to implement at a large scale. In this context, technologies embedded in smartphones offer new opportunities to develop remote tests. ObjectivesThis study aimed to test the validity and reliability of MediEval, a newly developed app-based medical device that allows individuals to perform the 6-minute walk test (6MWT) and the 30-second sit-to-stand (30s-STS) test on their own using GPS signal and camera detection with a skeleton extraction algorithm. MethodsA total of 53 healthy adults performed the two tests in three different sessions to determine the intra- and inter-day reproducibility. Test validity was assessed by comparing the results obtained from the app to gold standard measures. Pearson correlations and concordance correlation coefficients, the relative measurement error, intraclass correlation coefficients, the standard error of measure and the minimal detectable change were computed for each test.s ResultsThe results revealed high to excellent validity of the app in comparison to gold standards (& rho; = 0.84 for the 6MWT and & rho; = 0.99 for the 30s-STS test) with low relative measurement error. The mean differences between the app and the gold standard measures were 8.96m for the 6MWT and 0.28 repetition for the 30s-STS test. Both tests had good test-retest reliability (ICCs = 0.77). The minimal detectable changes were respectively 97.56 meters for the 6MWT and 7.37 repetitions for the 30s-STS test. ConclusionThe MediEval medical device proposes valid and reproducible measures of the 6MWT and the 30s-STS test. This device holds promise for monitoring the physical activity of large epidemiologic cohorts while refining patient experience and improving the scalability of the healthcare system. Considering minimal detectable change values, it may be important to ask participants to perform several tests and average them to improve accuracy. Future studies in clinical context are needed to evaluate the responsiveness and the smallest detectable changes of the device for specific populations with chronic diseases.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Effects of an App-Based Physical Exercise Program on Selected Parameters of Physical Fitness of Females in Retirement: A Randomized Controlled Trial
    Jungreitmayr, Sonja
    Kranzinger, Christina
    Venek, Verena
    Ring-Dimitriou, Susanne
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [32] Reliability and validity of a school-based physical activity questionnaire
    Wong, Suzy L.
    Leatherdale, Scott T.
    Manske, Stephen R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (09): : 1593 - 1600
  • [33] Normative data of a smartphone app-based 6-minute walking test, test-retest reliability, and content validity with patient-reported outcome measures
    Tosic, Lazar
    Goldberger, Elior
    Maldaner, Nicolai
    Sosnova, Marketa
    Zeitlberger, Anna M.
    Staartjes, Victor E.
    Gadjradj, Pravesh S.
    Eversdijk, Hubert A. J.
    Quddusi, Ayesha
    Gandia-Gonzalez, Maria L.
    Sayadi, Jamasb Joshua
    Desai, Atman
    Regli, Luca
    Gautschi, Oliver P.
    Stienen, Martin N.
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 33 (04) : 480 - 489
  • [34] Evaluating the reliability and validity of vericator as a voice-based measure of deception
    Sommers, MS
    Brown, T
    Senter, S
    Ryan, A
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2002, 45 (1-2) : 28 - 28
  • [35] Insights and anatomy of brand experience in app-based retailing (eRBX): Critical play of physical evidence and enjoyment
    Mondal, Jalaluddin
    Chakrabarti, Somnath
    JOURNAL OF RETAILING AND CONSUMER SERVICES, 2021, 60
  • [36] User Engagement and Attrition in an App-Based Physical Activity Intervention: Secondary Analysis of a Randomized Controlled Trial
    Edney, Sarah
    Ryan, Jillian C.
    Olds, Tim
    Monroe, Courtney
    Fraysse, Francois
    Vandelanotte, Corneel
    Plotnikoff, Ronald
    Curtis, Rachel
    Maher, Carol
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2019, 21 (11)
  • [37] Feasibility of Mobile Health App-Based Home Aerobic Exercise for Physical Performance in Healthy Young Adults
    Nam, Je Shik
    Kim, Hyun-Ah
    Kwak, Taejin
    Cho, Kang Hee
    Jung, Il-Young
    Moon, Chang -Won
    ANNALS OF REHABILITATION MEDICINE-ARM, 2024, 48 (01): : 75 - 85
  • [38] Randomized controlled trial evaluating the benefit of the app-based clinical decision support system for the management of venous thromboembolism
    Chairat, Pajaree
    Niprapan, Piangrawee
    Hantrakun, Nonthakorn
    Tantiworawit, Adisak
    Punnachet, Teerachat
    Piriyakhuntorn, Pokpong
    Rattanathammethee, Thanawat
    Hantrakool, Sasinee
    Rattarittamrong, Ekarat
    Norasetthada, Lalita
    Chai-Adisaksopha, Chatree
    BMC MEDICAL EDUCATION, 2025, 25 (01)
  • [39] The accuracy and reliability of an app-based audiometer using consumer headphones: pure tone audiometry in a normal hearing group
    Corry, Megan
    Sanders, Michael
    Searchfield, Grant D.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2017, 56 (09) : 706 - 710
  • [40] Reliability and validity of a physical capacity evaluation used to assess individuals with intellectual disabilities and mental illness
    Jang, Yuh
    Chang, Tzyh-Chyang
    Lin, Keh-Chung
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2009, 32 (01) : 77 - 84