Tear-film evaporation flux and its relationship to tear properties in symptomatic and asymptomatic soft-contact-lens wearers

被引:5
|
作者
Kim, Young Hyun [1 ,2 ,3 ]
Graham, Andrew D. [2 ]
Li, Wing [1 ,2 ]
Dursch, Thomas J. [2 ,3 ]
Peng, Cheng-Chun [2 ,3 ,4 ]
Radke, Clayton J. [1 ,3 ]
Lin, Meng C. [1 ,2 ,5 ]
机构
[1] Univ Calif Berkeley, Herbert Wertheim Sch Optometry & Vis Sci, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Clin Res Ctr, Herbert Wertheim Sch Optometry & Vis Sci, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Chem & Biomol Engn Dept, Berkeley, CA 94720 USA
[4] CooperVis Inc, Pleasanton, CA 94588 USA
[5] Univ Calif Berkeley, Sch Optometry, 360 Minor Hall, Berkeley, CA 94720 USA
来源
CONTACT LENS & ANTERIOR EYE | 2023年 / 46卷 / 04期
关键词
Tear evaporation; Flow evaporimeter; Tear film; Soft contact lens; Contact-lens-wear discomfort; Hyperosmolarity; Evaporative dry eyes; Tear lipid layer; DRY-EYE; WATER-EVAPORATION; GLAND-DYSFUNCTION; SURFACE; OSMOLARITY; EVAPORIMETER; INSTABILITY; MORPHOLOGY; HYDROGEL; DYNAMICS;
D O I
10.1016/j.clae.2023.101850
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: With soft-contact-lens wear, evaporation of the pre-lens tear film affects the osmolarity of the post-lens tear film and this can introduce a hyperosmotic environment at the corneal epithelium, leading to discomfort. The purposes of the study are to ascertain whether there are differences in evaporation flux (i.e., the evaporation rate per unit area) between symptomatic and asymptomatic soft-contact-lens wearers, to assess the repeatability of a flow evaporimeter, and to assess the relationship between evaporation fluxes, tear properties, and environmental conditions. Methods: Closed-chamber evaporimeters commonly used in ocular-surface research do not control relative humidity and airflow, and, therefore, misestimate the actual tear-evaporation flux. A recently developed flow evaporimeter overcomes these limitations and was used to measure accurate in-vivo tear-evaporation fluxes with and without soft-contact-lens wear for symptomatic and asymptomatic habitual contact-lens wearers. Concomitantly, lipid-layer thickness, ocular-surface-temperature decline rate (i.e., degrees C/s), non-invasive tear break-up time, tear-meniscus height, Schirmer tear test, and environmental conditions were measured in a 5 visit study. Results: Twenty-one symptomatic and 21 asymptomatic soft-contact-lens wearers completed the study. A thicker lipid layer was associated with slower evaporation flux (p < 0.001); higher evaporation flux was associated with faster tear breakup irrespective of lens wear (p = 0.006). Higher evaporation flux was also associated with faster ocular-surface-temperature decline rate (p < 0.001). Symptomatic lens wearers exhibited higher evaporation flux than did asymptomatic lens wearers, however, the results did not reach statistical significance (p = 0.053). Evaporation flux with lens wear was higher than without lens wear but was also not statistically significant (p = 0.110). Conclusions: The repeatability of the Berkeley flow evaporimeter, associations between tear characteristics and evaporation flux, sample-size estimates, and near statistical significance in tear-evaporation flux between symptomatic and asymptomatic lens wearers all suggest that with sufficient sample sizes, the flow evaporimeter is a viable research tool to understand soft-contact-lens wear comfort.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Effect of environmental conditions on tear dynamics in soft contact lens wearers
    Maruyama, K
    Yokoi, N
    Takamata, A
    Kinoshita, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (08) : 2563 - 2568
  • [22] Antioxidant Protection of a Model Tear-Film Component in Soft Contact Lenses
    Scales, Charles W.
    Mahadevan, Shivkumar
    Sonoda, Leilani
    Lada, Mark
    Martin, Patricia
    Riederer, Donald
    Fadli, Zohra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [23] Tear film dynamics of a new soft contact lens
    Buch, John
    Riederer, Donald
    Scales, Charles
    Xu, Jie
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (05) : 1070 - 1078
  • [24] An exploratory study of lipid supplements on the tear film lipid layer of habitual soft contact lens wearers
    Rohit, Athira
    Willcox, Mark D. P.
    Mitchell, Todd W.
    Stapleton, Fiona
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [25] Tear proteomic analysis of young glasses, orthokeratology, and soft contact lens wearers
    Qin, Guoting
    Chao, Cecilia
    Lattery, Lauren J.
    Lin, Hong
    Fu, Wenjiang
    Richdale, Kathryn
    Cai, Chengzhi
    JOURNAL OF PROTEOMICS, 2023, 270
  • [26] Impact of Soft Contact Lens Wear on Tear Film Breakup Patterns, Meniscus Tear Volume, and Tear Film Stability
    Yokoi, Norihiko
    Sakai, Rieko
    Georgiev, Georgi As
    Kato, Hiroaki
    Sotozono, Chie
    Kinoshita, Shigeru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [27] Reliability of Tear Meniscus Height Measurements in Contact Lens Wearers and Its Relationship With Discomfort Symptoms
    Valencia-Nieto, Laura
    Lopez-de la Rosa, Alberto
    Lopez-Miguel, Alberto
    Gonzalez-Garcia, Maria J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (09): : 410 - 415
  • [28] Evaluation of tear film and the morphological changes of meibomian glands in young Asian soft contact lens wearers and non-wearers
    Gu, Tianpu
    Zhao, Lu
    Liu, Zhuzhu
    Zhao, Shaozhen
    Nian, Hong
    Wei, Ruihua
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [29] Differences in clinical parameters and tear film of tolerant and intolerant contact lens wearers
    Glasson, MJ
    Stapleton, F
    Keay, L
    Sweeney, D
    Willcox, MDP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (12) : 5116 - 5124
  • [30] Evaluation of tear film and the morphological changes of meibomian glands in young Asian soft contact lens wearers and non-wearers
    Tianpu Gu
    Lu Zhao
    Zhuzhu Liu
    Shaozhen Zhao
    Hong Nian
    Ruihua Wei
    BMC Ophthalmology, 20