Tear-film evaporation flux and its relationship to tear properties in symptomatic and asymptomatic soft-contact-lens wearers

被引:5
|
作者
Kim, Young Hyun [1 ,2 ,3 ]
Graham, Andrew D. [2 ]
Li, Wing [1 ,2 ]
Dursch, Thomas J. [2 ,3 ]
Peng, Cheng-Chun [2 ,3 ,4 ]
Radke, Clayton J. [1 ,3 ]
Lin, Meng C. [1 ,2 ,5 ]
机构
[1] Univ Calif Berkeley, Herbert Wertheim Sch Optometry & Vis Sci, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Clin Res Ctr, Herbert Wertheim Sch Optometry & Vis Sci, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Chem & Biomol Engn Dept, Berkeley, CA 94720 USA
[4] CooperVis Inc, Pleasanton, CA 94588 USA
[5] Univ Calif Berkeley, Sch Optometry, 360 Minor Hall, Berkeley, CA 94720 USA
来源
CONTACT LENS & ANTERIOR EYE | 2023年 / 46卷 / 04期
关键词
Tear evaporation; Flow evaporimeter; Tear film; Soft contact lens; Contact-lens-wear discomfort; Hyperosmolarity; Evaporative dry eyes; Tear lipid layer; DRY-EYE; WATER-EVAPORATION; GLAND-DYSFUNCTION; SURFACE; OSMOLARITY; EVAPORIMETER; INSTABILITY; MORPHOLOGY; HYDROGEL; DYNAMICS;
D O I
10.1016/j.clae.2023.101850
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: With soft-contact-lens wear, evaporation of the pre-lens tear film affects the osmolarity of the post-lens tear film and this can introduce a hyperosmotic environment at the corneal epithelium, leading to discomfort. The purposes of the study are to ascertain whether there are differences in evaporation flux (i.e., the evaporation rate per unit area) between symptomatic and asymptomatic soft-contact-lens wearers, to assess the repeatability of a flow evaporimeter, and to assess the relationship between evaporation fluxes, tear properties, and environmental conditions. Methods: Closed-chamber evaporimeters commonly used in ocular-surface research do not control relative humidity and airflow, and, therefore, misestimate the actual tear-evaporation flux. A recently developed flow evaporimeter overcomes these limitations and was used to measure accurate in-vivo tear-evaporation fluxes with and without soft-contact-lens wear for symptomatic and asymptomatic habitual contact-lens wearers. Concomitantly, lipid-layer thickness, ocular-surface-temperature decline rate (i.e., degrees C/s), non-invasive tear break-up time, tear-meniscus height, Schirmer tear test, and environmental conditions were measured in a 5 visit study. Results: Twenty-one symptomatic and 21 asymptomatic soft-contact-lens wearers completed the study. A thicker lipid layer was associated with slower evaporation flux (p < 0.001); higher evaporation flux was associated with faster tear breakup irrespective of lens wear (p = 0.006). Higher evaporation flux was also associated with faster ocular-surface-temperature decline rate (p < 0.001). Symptomatic lens wearers exhibited higher evaporation flux than did asymptomatic lens wearers, however, the results did not reach statistical significance (p = 0.053). Evaporation flux with lens wear was higher than without lens wear but was also not statistically significant (p = 0.110). Conclusions: The repeatability of the Berkeley flow evaporimeter, associations between tear characteristics and evaporation flux, sample-size estimates, and near statistical significance in tear-evaporation flux between symptomatic and asymptomatic lens wearers all suggest that with sufficient sample sizes, the flow evaporimeter is a viable research tool to understand soft-contact-lens wear comfort.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Tear film in symptomatic and asymptomatic lens wearers
    Masoudi, Simin
    Stapleton, Fiona
    Willcox, Mark D. P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [2] Effect of Soft-Contact-Lens Wear on Post-Lens Tear-Film Osmolarity
    Kim, Young
    Thien Nguyen
    Lin, Meng
    Peng, Cheng-Chun
    Radke, Clayton
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [3] Differences in Tear Film Biochemistry of Symptomatic and Asymptomatic Lens Wearers
    Masoudi, Simin
    Stapleton, Fiona J.
    Willcox, Mark D. P.
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (09) : 914 - 918
  • [4] A PROPOSED MECHANISM FOR INCREASED TEAR-FILM OSMOLARITY IN CONTACT-LENS WEARERS
    GILBARD, JP
    GRAY, KL
    ROSSI, SR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1986, 102 (04) : 505 - 507
  • [5] Influence of the tear film composition on tear film structure and symptomatology of soft contact lens wearers
    Guillon, Michel
    Maissa, Cecile
    Girard-Claudon, Karine
    Cooper, Philip
    2000, Williams & Wilkins Co, Baltimore (77)
  • [6] Influence of the tear film composition on tear film structure and symptomatology of soft contact lens wearers
    Guillon, M
    Maissa, C
    Girard-Claudon, K
    Cooper, P
    LACRIMAL GLAND, TEAR FILM, AND DRY EYE SYNDROMES 3: BASIC SCIENCE AND CLINICAL RELEVANCE, PTS A & B, 2002, 506 : 895 - 899
  • [7] Preocular tear film characteristics of nonwearers and soft contact lens wearers
    Guillon, M
    Styles, E
    Guillon, JP
    Maissa, C
    OPTOMETRY AND VISION SCIENCE, 1997, 74 (05) : 273 - 279
  • [8] End-of-day assessment of tear film biomarkers in asymptomatic versus highly symptomatic soft lens wearers
    Navascues-Cornago, Maria
    Maldonado-Codina, Carole
    Snith, Sarah
    Read, Michael
    Lakkis, Carol
    Franklin, Ross
    Hai, Yang
    Liang, Bailin
    Morgan, Philip
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [9] Tear film characteristics in contact lens wearers.
    Leach, NE
    Dabney, BW
    Robertson, DM
    Narayanan, S
    Miller, WM
    Bergmanson, JPG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S592 - S592
  • [10] Post-lens tear-film depletion due to evaporative dehydration of a soft contact lens
    Fornasiero, F
    Prausnitz, JM
    Radke, CJ
    JOURNAL OF MEMBRANE SCIENCE, 2006, 275 (1-2) : 229 - 243