Application of homemade portable gas chromatography coupled to photoionization detector for the detection of volatile organic compounds in an industrial park

被引:2
|
作者
Pang, Xiaobing [1 ,2 ]
Li, Wenke [1 ]
Wang, Shuaiqi [2 ]
Wu, Zhentao [2 ]
Sun, Songhua [3 ]
Lyu, Yan [2 ]
Chen, Dongzhi [4 ]
Li, Haiyan [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Sch Environm & Energy Engn, Beijing 100044, Peoples R China
[2] Zhejiang Univ Technol, Coll Environm, Hangzhou 310000, Peoples R China
[3] Shaoxing Ecol & Environm Monitoring Ctr Zhejiang P, Shaoxing 312000, Peoples R China
[4] Zhejiang Ocean Univ, Sch Petrochem Engn & Environm, Zhoushan 316022, Peoples R China
关键词
Portable GC-PID( p GC-PID); Volatile organic compounds (VOCs); Industrial park; Online analysis; OZONE FORMATION; HEALTH-RISK; VOCS; BTEX; PROFILES; LEVEL; GC; EMISSIONS; BENZENE; EXHAUST;
D O I
10.1016/j.chroma.2023.464089
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional offline detection of volatile organic compounds (VOCs) requires complex and time-consuming pre-treatments including gas sampling in containers, pre-concentrations, and thermal desorption, which hinders its application in rapid VOCs monitoring. Developing a cost-effective instrument is of great im-portance for online measurement of VOCs. Recently, photoionization detectors (PID) are received great attention due to their fast response time and high sensitivity. This study a portable gas chromatography coupled to PID (pGC-PID) was developed and optimized experimental parameters for the application in online monitoring of VOCs at an industrial site. The sampling time, oven temperature and carrier gas flow rate were optimized as 80 s, 50 & DEG;C and 60 ml & BULL;min -1, respectively. The sampling method is direct injec-tion. Poly tetra fluoroethylene (PTFE) filter membranes were selected to remove particulate matter from interfering with PID. The reproducibility and peak separation were good with relative standard deviations (RSD) < 7%. Good linearities of 27 VOCs standard curves were achieved with R 2 > 0.99, and the detection limits were <10 ppb with the lowest being 2 ppb for 1,1,2-Trichloroethane. Finally, the pGC-PID is suc-cessfully applied in online VOCs monitoring at an industrial site. A total of 17 VOCs species was detected and their diurnal variations were well obtained, indicating pGC-PID is well suited for online analysis in field campaign. & COPY; 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Characterization of Volatile Organic Compounds in the Vicinity of an Optoelectronics Industrial Park in Taiwan
    Chang, Ta-Yuan
    Lin, Shen-Ju
    Shie, Ruei-Hao
    Tsai, Shih-Wei
    Hsu, Hui-Tsung
    Tsai, Ching-Tsan
    Kuo, Hsien-Wen
    Chiang, Chow-Feng
    Lai, Jim-Shoung
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2010, 60 (01) : 55 - 62
  • [22] The properties of chromatomembrane cells in flow systems coupled to gas chromatography - analysis of volatile organic compounds
    Bloch, C
    Simon, J
    Moskvin, LN
    Rodinkov, OV
    TALANTA, 2000, 52 (01) : 123 - 128
  • [23] Inverse gas chromatography characterization of polyaniline complexes: application to volatile organic compounds sensing
    Mekki, Ahmed
    Mettai, Boualem
    Ihdene, Zaher
    Mahmoud, Rachid
    Mekhalif, Zineb
    IRANIAN POLYMER JOURNAL, 2013, 22 (09) : 677 - 687
  • [24] Inverse gas chromatography characterization of polyaniline complexes: application to volatile organic compounds sensing
    Ahmed Mekki
    Boualem Mettai
    Zaher Ihdene
    Rachid Mahmoud
    Zineb Mekhalif
    Iranian Polymer Journal, 2013, 22 : 677 - 687
  • [25] DETERMINATION OF VOLATILE ORGANIC-COMPOUNDS IN WATER AND SOIL BY GAS-CHROMATOGRAPHY AND ION TRAP DETECTOR
    KRAUTVASS, A
    KRAUT, B
    MAGYAR KEMIAI FOLYOIRAT, 1992, 98 (11): : 421 - 429
  • [26] Enhancement of the detection sensitivity for volatile organic compounds by using an annular type photoionization detector and a pre-concentration system
    Song, Kyuseok
    Ahn, Bowha
    Jung, Euochang
    Lee, Yong-Ill
    Ko, Sungsuk
    ANALYTICA CHIMICA ACTA, 2007, 583 (01) : 210 - 215
  • [27] Selective detection of volatile aromatic compounds using a compact laser ionization detector with fast gas chromatography
    Meyer, MJ
    Schieffer, GM
    Moeker, EK
    Brodersen, JJ
    Swenson, OF
    Borgerding, AJ
    ANALYTICAL CHEMISTRY, 2004, 76 (06) : 1702 - 1707
  • [28] Determination of volatile organic compounds in wastewater by gas chromatography.
    Nairi, P
    Tua, G
    Josse, D
    Carlotti, MP
    Clair, P
    ANALUSIS, 1996, 24 (05) : 211 - 214
  • [29] ANALYSIS OF VOLATILE ORGANIC SULFUR COMPOUNDS BY GAS PARTITION CHROMATOGRAPHY
    RYCE, SA
    BRYCE, WA
    ANALYTICAL CHEMISTRY, 1957, 29 (06) : 925 - 928
  • [30] Membrane and trap system for continuous monitoring of volatile organic compounds using a portable gas chromatograph with thermal conductivity detector
    Ciucanu, I
    Chiriac, A
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (07) : 447 - 452