Does Head and Neck Posture Affect Cone-Beam Computed Tomography Assessment of the Upper Airway?

被引:4
|
作者
Coppelson, Kevin [1 ,8 ]
Summersgill, Isabella [1 ]
Hatcher, David [2 ,3 ,4 ,5 ,6 ,7 ]
Nguyen, Gloria [1 ]
Pada, Hilary [1 ]
Stewart, Hal [1 ]
Herre, Tim [1 ]
Hansen, Michael [1 ]
Zaghi, Soroush [1 ]
机构
[1] Breathe Inst, Los Angeles, CA USA
[2] Univ Pacific, Sch Dent, Dept Orthodont, San Francisco, CA USA
[3] Univ Calif San Francisco, Sch Dent, Orofacial Sci, San Francisco, CA USA
[4] Univ Calif Los Angeles, Sch Dent, Los Angeles, CA USA
[5] Univ Calif Davis, Sch Vet Med, Dept Surg & Radiol Sci, Davis, CA USA
[6] Diagnost Digital Imaging, Sacramento, CA USA
[7] BeamReaders, Kennewick, WA USA
[8] Breathe Inst, 10921 Wilshire Blvd Suite 912, Los Angeles, CA 90024 USA
关键词
OBSTRUCTIVE SLEEP-APNEA; CEPHALOMETRIC MEASUREMENTS; LATERAL CEPHALOGRAMS; CLASS-II; DIMENSIONS; POSITION; VOLUME; SNORERS; UPRIGHT; TONGUE;
D O I
10.1016/j.joms.2023.01.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Radiographic analysis is often used as a screening tool to assess for risk of sleep-related breath-ing disorders. This study aimed to address 2 questions: (1) Does head posture significantly affect the min-imum cross-sectional area (MCA)? and (2) Is the NBC3 (nasion-basion-C3) angle a reliable measurement to control for alteration of head position in cone-beam computed tomography (CBCT) scans? Methods: Study design: prospective cohort study. Setting: Private practices affiliated with a research institution. Participants: convenience sample of adult volunteers. Variables: CBCT scans were taken in 2 conditions: baseline (natural head position, NHP) and 1 of 5 experimental conditions (head tilted up, head tilted down, sitting vs standing, use of chin-rest, and swallow variation). For the primary aim of our study, the primary predictor variable was head posture and the main outcome variable was percentage change in MCA. For the secondary aim, the primary predictor variable was head posture and the main outcome variable was degree change in NBC3 angle. Results: Ninety subjects were included (age 40.7 ⠂ 13.7 years, 70% female). Mean NBC3 at baseline was 112.4 ⠂ 8.3 ⠃. Head tilted down significantly decreased (⠄41.4 ⠂ 18.5 mm2, P = .03*) and head tilted up significantly increased MCA (+147.4 ⠂ 43.3 mm2, P = .0018*). Head tilted down significantly reduced the NBC3 angle measurement (⠄10.5 ⠂ 6.8 ⠃, P = .006) and head tilted up significantly increased the NBC3 angle measurement (+14.4 ⠂ 5.8 ⠃, P = .0004). A quadratic regression model was fitted with moderately strong correlation (R2 = 0.54) showing an exponential effect of small changes in the NBC3 angle on MCA, P < .0001. The model predicts that increasing NBC3 by +5 and + 10 ⠃ resulted in MCA changes of +25% and +88%, whereas a decrease in NBC3 by ⠄5 and ⠄10 ⠃ results in MCA changes of ⠄21% and ⠄23%, respectively.Conclusion: Alterations in head posture significantly affect the MCA of the upper airway on CBCT. The NBC3 angle can be used to reliably assess changes in cranio-cervical extension and validate comparisons of MCA between CBCT scans for the same patient. A standardized protocol for CBCT acquisition is proposed.& COPY; 2023 The Authors. Published by Elsevier Inc. on behalf of the American Association of Oral and Maxillofacial Surgeons. This is an open access article under the CC BY license (http:// creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:721 / 733
页数:13
相关论文
共 50 条
  • [31] Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report
    Darsey, Drew M.
    English, Jeryl D.
    Kau, Chung H.
    Ellis, Randy K.
    Akyalcin, Sercan
    IMAGING SCIENCE IN DENTISTRY, 2012, 42 (02) : 83 - 88
  • [32] Cone beam computed tomography: An innovative tool for airway assessment
    Osorio, Federico
    Perilla, Mauricio
    Doyle, D. John
    Palomo, J. Martin
    ANESTHESIA AND ANALGESIA, 2008, 106 (06): : 1803 - 1807
  • [33] Cone-beam computed tomography airway measurements: Can we trust them?
    Obelenis Ryan, Daniel Patrick
    Bianchi, Jonas
    Ignacio, Jaqueline
    Wolford, Larry Miller
    Goncalves, Joao Roberto
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (01) : 53 - 60
  • [34] Dimensional changes of upper airway after rapid maxillary expansion: A prospective cone-beam computed tomography study
    Chang, Yoon
    Koenig, Lisa J.
    Pruszynski, Jessica E.
    Bradley, Thomas G.
    Bosio, Jose A.
    Liu, Dawei
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (04) : 462 - 470
  • [35] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [36] When static meets dynamic: Comparing cone-beam computed tomography and acoustic reflection for upper airway analysis
    Tsolakis, Ioannis A.
    Venkat, Divya
    Hans, Mark G.
    Alonso, Aurelio
    Palomo, J. Martin
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (04) : 643 - 650
  • [37] Root canal sealers affect artifacts on cone-beam computed tomography images
    Miyashita, Hazuki
    Asaumi, Rieko
    Sakamoto, Ayaka
    Kawai, Taisuke
    Igarashi, Masaru
    ODONTOLOGY, 2021, 109 (03) : 679 - 686
  • [38] Root canal sealers affect artifacts on cone-beam computed tomography images
    Hazuki Miyashita
    Rieko Asaumi
    Ayaka Sakamoto
    Taisuke Kawai
    Masaru Igarashi
    Odontology, 2021, 109 : 679 - 686
  • [39] Validation of an Automated Segmentation Method for Head and Neck Adaptive Radiotherapy using Cone-beam Computed Tomography (CBCT)
    Chau, L.
    Allaire, S.
    Brock, K. K.
    Pekar, V.
    Waldron, J. N.
    Breen, S. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S143 - S143
  • [40] Practically Acquired and Modified Cone-Beam Computed Tomography Images for Accurate Dose Calculation in Head and Neck Cancer
    Hu, Chih-Chung
    Huang, Wen-Tao
    Tsai, Chiao-Ling
    Wu, Jian-Kuen
    Chao, Hsiao-Ling
    Huang, Guo-Ming
    Wang, Chun-Wei
    Wu, Chien-Jang
    Cheng, Jason Chia-Hsien
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (10) : 633 - 644