Probing the Pore Structure of the Berea Sandstone by Using X-ray Micro-CT in Combination with ImageJ Software

被引:7
|
作者
Hu, Zhazha [1 ,2 ]
Zhang, Rui [3 ]
Zhu, Kai [4 ]
Li, Dongyin [1 ]
Jin, Yi [5 ]
Guo, Wenbing [1 ]
Liu, Xiao [1 ]
Zhang, Xiaodong [1 ]
Zhang, Qian [3 ]
机构
[1] Henan Polytech Univ, Sch Energy Sci & Engn, Jiaozuo 454003, Peoples R China
[2] Henan Polytech Univ, Henan Key Lab Green & Efficient Min & Comprehens U, Jiaozuo 454003, Peoples R China
[3] Peking Univ, Inst Energy, Sch Earth & Space Sci, Beijing 100871, Peoples R China
[4] China Univ Geosci Beijing, Sch Energy Resources, Beijing 100083, Peoples R China
[5] Henan Polytech Univ, Inst Resources & Environm, Jiaozuo 454003, Peoples R China
基金
中国国家自然科学基金;
关键词
pore structure; porosity; permeability; image analysis; ImageJ software; POROSIMETRY; TOMOGRAPHY; BENCHMARKS; POROSITY; ROCK; FLOW;
D O I
10.3390/min13030360
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
During diagenesis, the transformation of unconsolidated sediments into a sandstone is usually accompanied by compaction, water expulsion, cementation and dissolution, which fundamentally control the extent, connectivity and complexity of the pore structure in sandstone. As the pore structure is intimately related to fluid flow in porous media, it is of great importance to characterize the pore structure of a hydrocarbon-bearing sandstone in a comprehensive way. Although conventional petrophysical methods such as mercury injection porosimetry, low-pressure nitrogen or carbon dioxide adsorption are widely used to characterize the pore structure of rocks, these evaluations are based on idealized pore geometry assumptions, and the results lack direct information on the pore geometry, connectivity and tortuosity of pore channels. In view of the problems, X-ray micro-CT was combined with ImageJ software (version 1.8.0) to quantitatively characterize the pore structure of Berea Sandstone. Based on its powerful image processing function, a series of treatments such as contrast enhancement, noise reduction and threshold segmentation, were first carried out on the micro-CT images of the sandstone via ImageJ. Pores with sizes down to 2.25 mu m were accurately identified. Geometric parameters such as pore area, perimeter and circularity could thus be extracted from the segmented pores. According to our evaluations, pores identified in this study are mostly in the range of 30-180 mu m and can be classified into irregular, high-circularity and slit-shaped pores. An irregular pore is the most abundant type, with an area fraction of 72.74%. The average porosity obtained in the image analysis was 19.10%, which is fairly close to the experimental result determined by a helium pycnometer on the same sample. According to the functional relationship between tortuosity and permeability, the tortuosity values of the pore network were estimated to be in the range of 4-6 to match the laboratory permeability data.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A Reconstruction of the Lophophore of Devonian Rhynchonellids (Brachiopoda) by Using X-Ray Micro-CT
    Pakhnevich, A. V.
    PALEONTOLOGICAL JOURNAL, 2017, 51 (02) : 143 - 154
  • [22] Investigation of water and CO2 flooding using pore-scale reconstructed model based on micro-CT images of Berea sandstone core
    Liu, Jianjun
    Song, Rui
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2015, 15 (05): : 317 - 326
  • [23] An enhanced tool for probing the microscopic behavior of granular materials based on X-ray micro-CT and FDEM
    Chen, Yuan
    Ma, Gang
    Zhou, Wei
    Wei, Deheng
    Zhao, Qi
    Zou, Yuxiong
    Grasselli, Giovanni
    COMPUTERS AND GEOTECHNICS, 2021, 132
  • [24] Accurate Resolution Measurement for X-Ray Micro-CT Systems
    Sen Sharma, K.
    Seshadri, S.
    Feser, M.
    Wang, G.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 337 - 340
  • [25] Micro-CT of small insects by projection X-ray microscopy
    Tanisako, Akira
    Tsuruta, Susumu
    Hori, Ayumi
    Okumura, Aya
    Miyata, Chikara
    Kuzuryu, Chiaki
    Obi, Takashi
    Yoshimura, Hideyuki
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [26] Micro-CT scanner with a focusing polycapillary x-ray optic
    Jorgensen, SM
    Reyes, DA
    MacDonald, CA
    Ritman, EL
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 158 - 166
  • [27] Micro-CT of Pseudocneorhinus bifasciatus by projection X-ray microscopy
    Tanisako, A
    Hori, A
    Okumura, A
    Miyata, C
    Kuzuryu, C
    Obi, T
    Yoshimura, H
    JOURNAL OF ELECTRON MICROSCOPY, 2005, 54 (04): : 379 - 383
  • [28] Research and Development on X-ray Micro-CT System for MEMS
    Fu Jian
    Li Bin
    Zhou Zhenggan
    Wei Dongbo
    Zhou Xingyu
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 1947 - 1950
  • [29] X-ray Micro-CT: How Soil Pore Space Description Can Be Altered by Image Processing
    Smet, Sarah
    Plougonven, Erwan
    Leonard, Angelique
    Degre, Aurore
    Beckers, Eleonore
    VADOSE ZONE JOURNAL, 2018, 17 (01)
  • [30] Characterization of oil shale pore structure before and after pyrolysis by using X-ray micro CT
    Tiwari, P.
    Deo, M.
    Lin, C. L.
    Miller, J. D.
    FUEL, 2013, 107 : 547 - 554