Simultaneous analysis of carcinogenic N-nitrosamine impurities in metformin tablets using on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry

被引:6
|
作者
Ishizaki, Atsushi [1 ]
Ozawa, Kazutaka [1 ]
Kataoka, Hiroyuki [1 ]
机构
[1] Shujitsu Univ, Sch Pharm, Nishigawara, Okayama 7038516, Japan
关键词
N-nitrosamines; Metformin; Pharmaceutical impurities; In-tube solid-phase microextraction; Liquid chromatography-tandem mass spectrometry; MS/MS METHOD; VALSARTAN;
D O I
10.1016/j.chroma.2023.464416
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contamination of active pharmaceutical ingredients (APIs) and pharmaceutical preparations with carcinogenic N-nitrosamines has led to recalls of these products and supply shortages to patients. The present study describes the development of a highly sensitive method for simultaneous analysis of seven N-nitrosamines using on-line in tube solid-phase microextraction (IT-SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine their actual contamination in metformin tablets. Using a Carboxen 1006 PLOT capillary as the extraction device for IT-SPME, these compounds were efficiently extracted and concentrated 624-fold by subjecting 40 mu L of sample to 25 repeated draw/eject cycles at a rate of 0.2 mL/min. The seven N- nitrosamines were separated within 11 min by gradient elution with 0.1 % formic acid solution and acetonitrile as the mobile phase using a CAPCELL PAK C18 MGII column and detected by multiple reaction monitoring in positive ion mode. The calibration curve showed linearity in the range 0.2-50 ng/mL and detection limits (S/N = 3) in the range 3-112 pg/mL. The intra-day and inter-day precisions were less than 5.5 % and 7.0 % (n = 6), respectively, with accuracies ranging from 93-117 %. Following ultrasonic extraction with water, centrifugation and filtration of the supernatant liquid through a membrane filter, the N-nitrosamine impurities in metformin tablets could be analyzed by IT-SPME/LC-MS/MS. Their limits of quantification (S/N =10) were 0.1-5.1 pg/mg API and recoveries ranged from 87-102 %. Analysis of eight metformin tablets from eight manufacturers showed that 5.8-7.5 pg/mg N-nitrosodimethylamine were present in three tablets, with no other N-nitrosamines detected in any of the eight tablets. This method may be useful in testing for N-nitrosamine impurities in pharmaceutical preparations.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Development of in-tube solid-phase microextraction/liquid chromatography/electrospray ionization mass spectrometry for the analysis of mutagenic heterocyclic amines
    Kataoka, H
    Pawliszyn, J
    CHROMATOGRAPHIA, 1999, 50 (9-10) : 532 - 538
  • [42] Determination of Ochratoxin A in wine by packed in-tube solid phase microextraction followed by high performance liquid chromatography coupled to tandem mass spectrometry
    Andrade, Mariane A.
    Lancas, Fernando M.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1493 : 41 - 48
  • [43] Quantitative determination of risperidone, paliperidone and olanzapine in human serum by liquid chromatography-tandem mass spectrometry coupled with on-line solid-phase extraction
    Ruan, Can-Jun
    Guo, Wei
    Zhou, Miao
    Guo, Gui-Xin
    Wang, Chuan-Yue
    Li, Wen-Biao
    de Leon, Jose
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (07)
  • [44] Validation of an on-line solid-phase extraction method coupled to liquid chromatography-tandem mass spectrometry detection for the determination of Indacaterol in human serum
    Emotte, Corinne
    Heudi, Olivier
    Deglave, Fanny
    Bonvie, Adrien
    Masson, Laurence
    Picard, Franck
    Chaturvedi, Animesh
    Majumdar, Tapan
    Agarwal, Ashish
    Woessner, Ralph
    Kretz, Olivier
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 895 : 1 - 9
  • [45] Graphene oxide based in-tube solid-phase microextraction combined with liquid chromatography tandem mass spectrometry for the determination of triazine herbicides in water
    Tan, Feng
    Zhao, Cong
    Li, Lianjun
    Liu, Min
    He, Xin
    Gao, Jinsuo
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (13) : 2312 - 2319
  • [46] On-fibre solid-phase microextraction coupled to conventional liquid chromatography versus in-tube solid-phase microextraction coupled to capillary liquid chromatography for the screening analysis of triazines in water samples
    Chafer-Pericas, C.
    Herraez-Hernandez, R.
    Campins-Falco, P.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (02) : 159 - 171
  • [47] Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography tandem mass spectrometry
    Kwok, W. H.
    Leung, David K. K.
    Leung, Gary N. W.
    Wan, Terence S. M.
    Wong, Colton H. F.
    Wong, Jenny K. Y.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (19) : 3289 - 3296
  • [48] Determination of patulin in fruit juice and dried fruit samples by in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry
    Kataoka, H.
    Itano, M.
    Ishizaki, A.
    Saito, K.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3746 - 3750
  • [49] On-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry optimized for the analysis of steroid hormones in urban wastewaters
    Fayad, Paul B.
    Prevost, Michele
    Sauve, Sebastien
    TALANTA, 2013, 115 : 349 - 360
  • [50] Determination of daidzein and genistein in soybean foods by automated on-line in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Mitani, K
    Narimatsu, S
    Kataoka, H
    JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (02) : 169 - 177