Topology optimization of convective heat transfer by the lattice Boltzmann method
被引:10
|
作者:
Luo, Ji-Wang
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
Luo, Ji-Wang
[1
]
Chen, Li
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
Chen, Li
[1
]
He, An
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Inst Ind Sci, Meguro Ku, Tokyo, JapanXi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
He, An
[2
]
Tao, WenQuan
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
Tao, WenQuan
[1
]
机构:
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
[2] Univ Tokyo, Inst Ind Sci, Meguro Ku, Tokyo, Japan
Topology optimization (TO) is a dependable approach to obtain innovative designs with improved performance. This study presents a TO method based on the adjoint lattice Boltzmann method (ALBM) and the level set method which is developed for both one-way coupled and two-way coupled convective heat transfer problems. The adjoint lattice Boltzmann model for fully coupled natural convection system is derived, and the coupled solution strategy is applied in the ALBM. The forward model is validated by the finite element simulation, while the adjoint model and the sensitivity expression is validated by a finite difference check, and the whole TO method is validated by a typical pure fluid flow optimization problem given in the literature. The validated TO method is then applied to enhance the heat transfer of forced convection in a two-dimensional open chamber, and the Pareto frontier of the bi-objective optimization is further presented and the effects of the blockages at the inlet and outlet on the overall performance are revealed. Finally, the two-dimensional natural convection process in a closed cavity is optimized, in which the effective heat transfer coefficient can be increased to 3.96 similar to 6.11 times of that without the optimized design when the Grashof number ranges from 1.7 to 4.2 x 10(5). Moreover, effects of Grashof number, porosity limitation and solid thermal diffusivity on the optimization results are analyzed in detail. Physically reasonable designs are obtained for both forced convection and natural convection systems under various parameter settings, demonstrating the effectiveness and robustness of the presented TO method.
机构:
Lab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, FranceLab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, France
Dugast, Florian
Favennec, Yann
论文数: 0引用数: 0
h-index: 0
机构:
Lab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, FranceLab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, France
Favennec, Yann
Josset, Christophe
论文数: 0引用数: 0
h-index: 0
机构:
Lab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, FranceLab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, France
Josset, Christophe
Fan, Yilin
论文数: 0引用数: 0
h-index: 0
机构:
Lab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, FranceLab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, France
Fan, Yilin
Luo, Lingai
论文数: 0引用数: 0
h-index: 0
机构:
Lab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, FranceLab Therm & Energie Nantes, UMR CNRS 6607, Rue Christian Pauc,BP 50609, F-44306 Nantes 03, France