Left Ventricular Ejection Time Estimation from Blood Pressure and Photoplethysmography Signals Based on Tidal Wave

被引:4
|
作者
Evdochim, Lucian [1 ]
Dobrescu, Dragos [1 ]
Dobrescu, Lidia [1 ]
Stanciu, Silviu [2 ]
Halichidis, Stela [3 ]
机构
[1] Univ Politehn Bucuresti, Fac Elect Telecommun & Informat Technol, Dept Elect Devices Circuits & Architectures, Bucharest 060042, Romania
[2] Dr Carol Davila Cent Mil Emergency Univ Hosp, Lab Cardiovasc Noninvas Invest, Bucharest 010825, Romania
[3] Ovidius Univ Constanta, Fac Med, Dept Clin Med Disciplines, Constanta 900527, Romania
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 19期
关键词
tidal wave; dicrotic wave; left ventricular ejection time; photoplethysmography; blood pressure; electrocardiogram; signal database; AORTIC PRESSURE; DOPPLER; FORM;
D O I
10.3390/app131911025
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application Left ventricular ejection time estimation by analyzing the morphology of arterial blood pressure and photoplethysmography signal.Abstract Left ventricular ejection time (LVET) is an important parameter for assessing cardiovascular disorders. In a medical office, it is typically measured using the Tissue Doppler Imaging technique, but new wearable devices have led to a growing interest in integrating this parameter into them, increasing accessibility to personalized healthcare for users and patients. In the cardiovascular domain, photoplethysmography (PPG) is a promising technology that shares two distinctive features with invasive arterial blood pressure (ABP) tracing: the tidal wave (TDW) and the dicrotic wave (DCW). In the early years of cardiovascular research, the duration of the dicrotic point was initially linked to the ending phase of left ventricular ejection. Subsequent studies reported deviations from the initial association, suggesting that the ejection period is related to the tidal wave feature. In this current study, we measured left ventricular ejection time in both ABP and PPG waveforms, considering recent research results. A total of 27,000 cardiac cycles were analyzed for both afore-mentioned signals. The reference value for ejection time was computed based on the T-wave segment duration from the electrocardiogram waveform. In lower blood pressure, which is associated with decreased heart contractility, the results indicated an underestimation of -29 +/- 19 ms in ABP and an overestimation of 18 +/- 31 ms in PPG. On the other side of the spectrum, during increased contractility, the minimum errors were -3 +/- 18 ms and 4 +/- 33 ms, respectively. Since the tidal wave feature is strongly affected by arterial tree compliance, the population evaluation results indicate a Pearson's correlation factor of 0.58 in the ABP case, and 0.53 in PPG. These findings highlight the need for advanced compensation techniques, in particular for PPG assessment, to achieve clinical-grade accuracy.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
    Xing, Xiaoman
    Sun, Mingshan
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (08): : 3007 - 3020
  • [42] Estimation System of Blood Pressure Variation with Photoplethysmography Signals Using Multiple Regression Analysis and Neural Network
    Cho, Seung-Il
    Negishi, Takumi
    Tsuchiya, Minami
    Yasuda, Muneki
    Yokoyama, Michio
    INTERNATIONAL JOURNAL OF FUZZY LOGIC AND INTELLIGENT SYSTEMS, 2018, 18 (04) : 229 - 236
  • [43] UK audit of left ventricular ejection fraction estimation from equilibrium ECG gated blood pool images
    Skrypniuk, JV
    Bailey, D
    Cosgriff, PS
    Fleming, JS
    Houston, AS
    Jarritt, PH
    Whalley, DR
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (03) : 205 - 215
  • [44] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Li-Ping Yao
    Zhong-liang Pan
    Physical and Engineering Sciences in Medicine, 2021, 44 : 397 - 408
  • [45] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Yao, Li-Ping
    Pan, Zhong-liang
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 397 - 408
  • [46] Blood pressure estimation based on heart sound signals
    Cheng Xie-Feng
    Dai Shi-Cheng
    Zhao Peng-Jun
    ACTA PHYSICA SINICA, 2020, 69 (14)
  • [47] Assessing heart rate and blood pressure estimation from image photoplethysmography using a digital blood pressure meter
    Trirongjitmoah, Suchin
    Promking, Arphorn
    Kaewdang, Khanittha
    Phansiri, Nisarut
    Treeprapin, Kriengsak
    HELIYON, 2024, 10 (05)
  • [48] Effects of ramipril on left ventricular mass and function in cardiovascular patients with controlled blood pressure and with preserved left ventricular ejection fraction
    Lonn, E
    Shaikholeslami, R
    Yi, QL
    Bosch, J
    Sullivan, B
    Tanser, P
    Magi, A
    Yusuf, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) : 2200 - 2206
  • [49] Cuff-Less Continuous Blood Pressure Estimation from Electrocardiogram(ECG) and Photoplethysmography (PPG) Signals with Artificial Neural Network
    Senturk, Umit
    Yucedag, Ibrahim
    Polat, Kemal
    2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [50] Estimation of left ventricular ejection fraction from the qualitative evaluation of suboptimal echocardiograms
    Raichlen, JS
    Kutner, HJ
    McDonald, ME
    Zhang, JJ
    JOURNAL OF INVESTIGATIVE MEDICINE, 1998, 46 (03) : 237A - 237A