Seismic performance of advanced three-dimensional base-isolated nuclear structures in complex-layered sites

被引:45
|
作者
Liu, Yu [1 ,2 ]
Li, Jianbo [1 ,2 ]
Lin, Gao [1 ,2 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, Inst Earthquake Engn, Fac Infrastruct Engn, Dalian 116024, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional base isolation; Soil -structure interaction; Nuclear island building; Beyond-design basis earthquake; Complex-layered sites; Isolation effectiveness; Global method; Rocking motion; FLOOR RESPONSE SPECTRA; STRONG GROUND MOTION; ISOLATION-SYSTEM; ARTIFICIAL BOUNDARY; EARTHQUAKE; DESIGN; STIFFNESS; DEVICE;
D O I
10.1016/j.engstruct.2023.116247
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The application of three-dimensional (3D) base isolation for nuclear structures is advantageous. In this study, an advanced 3D base isolation technique was developed and the nonlinear seismic response of 3D base-isolated nuclear structures in complex layered sites was investigated using a global method. The study first designed a novel 3D isolation system, including horizontal and vertical isolation, based on the disc spring theory, which can flexibly adjust the structural stiffness and vertical bearing capacity. To verify the applicability of 3D base isolation, the dynamic behaviour of a 3D base-isolated nuclear island building in complex-layered sites subjected to beyond-design basis ground motion was investigated using a proposed high-precision simulation program of soil-structure interaction (SSI) based on the global method. The findings demonstrate that in complex-layered sites, the SSI increases the horizontal floor response spectra (FRS) but decreases the vertical FRS of 3D baseisolated nuclear power plants, and both the horizontal and vertical isolation rates remarkably decrease. The influence of the SSI becomes more evident as the intensity of the ground motion increases. The proposed 3D base isolation system exhibits excellent isolation effects. When the vertical stiffness is reduced, the vertical isolation effect becomes more significant. However, the adverse rocking motion of the island building should be effectively controlled. The research results support the practical application of 3D base isolation technology for nuclear structures located in complex-layered sites with high seismic intensities.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Imaging complex three-dimensional structures, applying three-component vector migration to synthetic vertical seismic profiling data
    Haldorsen, Jakob B. U.
    Jahren, Leif
    GEOPHYSICAL PROSPECTING, 2021, 69 (07) : 1391 - 1404
  • [42] Development of elevated temperature structual design standard and three-dimensional seismic isolation technology for advanced nuclear power plant
    Inoue, Kazuhiko
    Shibamoto, Hiroshi
    Takahashi, Kenji
    Ikutama, Shinya
    Morishita, Masaki
    Aoto, Kazurni
    Kasahara, Naoto
    Asayama, Tai
    Kitamura, Seiji
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 2006, 48 (05): : 333 - 338
  • [43] Study on seismic safety evaluation of crossover pipeline connecting containment and turbine building in three-dimensional isolated nuclear power plant
    Kong, Derui
    Liu, Wenguang
    Yang, Jie
    Wang, Kai
    He, Wenfu
    NUCLEAR ENGINEERING AND DESIGN, 2023, 412
  • [44] Seismic Performance of Deeply Embedded Conceptual Advanced Reactors: Three-Dimensional Nonlinear Soil-Structure Interaction Analyses
    Kurt, Efe G.
    Spears, Robert
    NUCLEAR TECHNOLOGY, 2021, 207 (11) : 1664 - 1686
  • [45] The nuclear pore complex and lamina: Three-dimensional structures and interactions determined by field emission in-lens scanning electron microscopy
    Goldberg, MW
    Allen, TD
    JOURNAL OF MOLECULAR BIOLOGY, 1996, 257 (04) : 848 - 865
  • [46] Seismic performance improvement of a three-dimensional isolated spherical reticulated shell structure using pseudo-negative-stiffness magnetorheological dampers
    Zhuang, Peng
    Hu, Xiaoyu
    Zhang, Guowei
    SMART MATERIALS AND STRUCTURES, 2024, 33 (10)
  • [47] A novel flow-based geometrical upscaling method to represent three-dimensional complex sub-seismic fault zone structures into a dynamic reservoir model
    Islam, Md Saiful
    Manzocchi, Tom
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [48] A novel flow-based geometrical upscaling method to represent three-dimensional complex sub-seismic fault zone structures into a dynamic reservoir model
    Md Saiful Islam
    Tom Manzocchi
    Scientific Reports, 9
  • [49] Full Three-Dimensional Seismic Response Analysis of Underground Structures with Large Complex Cross Sections and Two-Step Analysis Method for Reducing the Computational Costs
    Ichimura, Tsuyoshi
    Tanaka, Seizo
    Hori, Muneo
    Yamamoto, Yujin
    Dobashi, Hiroshi
    Osada, Mitsumasa
    Ohbo, Naoto
    Yamada, Takemine
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2016, 10 (05)
  • [50] Remarkable kinetoplast, cytostome-cytopharynx complex, and storage-related structures as dissected by three-dimensional reconstruction of Trypanosoma sp. 858 isolated from a toad (Amphibia: Anura)
    Attias, Marcia
    Vidal, Juliana C.
    Takata, Carmem S. A.
    Campaner, Marta
    Camargo, Erney P.
    Teixeira, Marta M. G.
    De Souza, Wanderley
    MICRON, 2022, 152