A Comparative Study of Three Nucleic Acid Integrity Assay Systems

被引:0
|
作者
Lu, Xinyi [1 ]
Wei, Yulian [1 ]
Sun, Jing [1 ]
Xiao, Bo [1 ]
Zhang, Xiaoyan [2 ]
Li, Wanhua [1 ]
Chen, Ying [1 ]
Lin, Fengye [1 ]
Zhang, Li [2 ]
Wang, Yan [2 ]
Zheng, Jing [3 ]
Zheng, Lingyan [4 ]
Zhou, Xingzhi [5 ]
Chen, Qubo [1 ,6 ]
机构
[1] Guangzhou Univ Chinese Med, Affiliated Hosp 2, State Key Lab Dampness Syndrome Chinese Med, Guangzhou, Peoples R China
[2] Nat Engn Ctr Biochip Shanghai, Shanghai, Peoples R China
[3] PerkinElmer Management Shanghai Co Ltd, Shanghai, Peoples R China
[4] Hangzhou Houze Biotechnol Co Ltd, Hangzhou, Peoples R China
[5] Agilent Technol, Guangzhou, Peoples R China
[6] Guangzhou Univ Chinese Med, Affiliated Hosp 2, State Key Lab Dampness Syndrome Chinese Med, 111 Dade Rd, Guangzhou 510120, Peoples R China
关键词
methodological comparison; nucleic acid; quality evaluation; DNA Integrity Number; RNA Integrity Number;
D O I
10.1089/bio.2022.0171
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background: The measurement of nucleic acid quality, especially the analysis of integrity, is a key step for many downstream experiments in biomedical research and quality control of biomaterials. General gel electrophoresis is a traditional method for nucleic acid integrity analysis. Currently, more electrophoresis techniques are becoming standardized and automated operations with higher precision. In this study, we have evaluated the comparability and bias of the outcomes from three commercial assay systems.Methods: Seventy-two deoxyribonucleic acid (DNA) and 67 ribonucleic acid (RNA) samples were selected for methodological comparison among different systems. The DNA Quality Number (DQN) and RNA Quality Number (RQN) of BIOptic Qsep400, DNA Quality Score (DQS) and RNA Quality Score (RQS) of PerkinElmer Labchip GX Touch HT were separately compared with the DNA Integrity Number (DIN) and RNA Integrity Number (RINe) of the Agilent 4200 TapeStation according to Clinical and Laboratory Standards Institute (CLSI) guideline (EP09-A3).Results: The biases of the mean estimated between DQN and DIN, DQS and DIN both exceeded the acceptance criteria. The Passing-Bablok regression analysis between DQN and DIN, and the Deming regression analysis between DQS and DIN, showed the biases were both within the acceptance criteria, and the bias between DQN and DIN was smaller. For the comparisons of RQN and RINe, RQS and RINe, the regression analyses revealed the biases were both within the acceptance criteria. The bias of the mean estimated between RQS and RINe was outside of the acceptance criteria.Conclusions: There was a good comparability in nucleic acid integrity detection between BIOptic Qsep400 and PerkinElmer Labchip GX Touch HT with the Agilent 4200 TapeStation. However, the bias and linear correlations require more attention between systems.
引用
收藏
页码:624 / 630
页数:7
相关论文
共 50 条
  • [21] Programming Non-Nucleic Acid Molecules into Computational Nucleic Acid Systems
    Zhang, Qiu-Long
    Wang, Yang
    Wang, Liang-Liang
    Xie, Fan
    Wu, Ruo-Yue
    Ma, Xu-Yang
    Li, Han
    Liu, Yan
    Yao, Shunchun
    Xu, Liang
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2023, 62 (02)
  • [22] A quantitative luminescence assay for nonradioactive nucleic acid probes
    Didenko, VV
    Hornsby, PJ
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1996, 44 (06) : 657 - 660
  • [23] Comparative analysis of three nucleic acid-based detection systems for hepatitis C virus RNA in plasma from liver transplant recipients
    Chen, YP
    Cooper, DL
    Ehrlich, GD
    MOLECULAR AND CELLULAR PROBES, 1996, 10 (05) : 331 - 336
  • [24] Fluorescent Nucleic Acid Systems for Biosensors
    Podder, Arup
    Lee, Ha Jung
    Kim, Byeang Hyean
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2021, 94 (03) : 1010 - 1035
  • [25] Microfabricated systems for nucleic acid analysis
    Obeid, PJ
    Christopoulos, TK
    CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2004, 41 (5-6) : 429 - 465
  • [26] Integrating Ligands into Nucleic Acid Systems
    Wang, Yang
    Liu, Yan
    Wang, Liang-Liang
    Zhang, Qiu-Long
    Xu, Liang
    CHEMBIOCHEM, 2023, 24 (18)
  • [27] NUCLEIC ACID METABOLISM IN CELL SYSTEMS
    GOPALAYENGAR, AR
    RADIATION RESEARCH, 1958, 9 (01) : 121 - 121
  • [28] Nucleic Acid Based Logical Systems
    Han, Da
    Kang, Huaizhi
    Zhang, Tao
    Wu, Cuichen
    Zhou, Cuisong
    You, Mingxu
    Chen, Zhuo
    Zhang, Xiaobing
    Tan, Weihong
    CHEMISTRY-A EUROPEAN JOURNAL, 2014, 20 (20) : 5866 - 5873
  • [29] Comparative evaluation of digoxin concentrations determined by three assay systems: TDx, IMx and OPUS
    Kagawa, Y
    Iwamoto, T
    Matsuda, H
    Mukohara, R
    Sawada, J
    Kojima, M
    BIOPHARMACEUTICS & DRUG DISPOSITION, 2004, 25 (01) : 21 - 26
  • [30] Comparative evaluation of three assay systems for automated determination of hemoglobin A(1c)
    HalwachsBaumann, G
    Katzensteiner, S
    Schnedl, W
    Purstner, P
    Pieber, T
    WildersTruschnig, M
    CLINICAL CHEMISTRY, 1997, 43 (03) : 511 - 517