共 50 条
A Comparative Study of Three Nucleic Acid Integrity Assay Systems
被引:0
|作者:
Lu, Xinyi
[1
]
Wei, Yulian
[1
]
Sun, Jing
[1
]
Xiao, Bo
[1
]
Zhang, Xiaoyan
[2
]
Li, Wanhua
[1
]
Chen, Ying
[1
]
Lin, Fengye
[1
]
Zhang, Li
[2
]
Wang, Yan
[2
]
Zheng, Jing
[3
]
Zheng, Lingyan
[4
]
Zhou, Xingzhi
[5
]
Chen, Qubo
[1
,6
]
机构:
[1] Guangzhou Univ Chinese Med, Affiliated Hosp 2, State Key Lab Dampness Syndrome Chinese Med, Guangzhou, Peoples R China
[2] Nat Engn Ctr Biochip Shanghai, Shanghai, Peoples R China
[3] PerkinElmer Management Shanghai Co Ltd, Shanghai, Peoples R China
[4] Hangzhou Houze Biotechnol Co Ltd, Hangzhou, Peoples R China
[5] Agilent Technol, Guangzhou, Peoples R China
[6] Guangzhou Univ Chinese Med, Affiliated Hosp 2, State Key Lab Dampness Syndrome Chinese Med, 111 Dade Rd, Guangzhou 510120, Peoples R China
关键词:
methodological comparison;
nucleic acid;
quality evaluation;
DNA Integrity Number;
RNA Integrity Number;
D O I:
10.1089/bio.2022.0171
中图分类号:
Q2 [细胞生物学];
学科分类号:
071009 ;
090102 ;
摘要:
Background: The measurement of nucleic acid quality, especially the analysis of integrity, is a key step for many downstream experiments in biomedical research and quality control of biomaterials. General gel electrophoresis is a traditional method for nucleic acid integrity analysis. Currently, more electrophoresis techniques are becoming standardized and automated operations with higher precision. In this study, we have evaluated the comparability and bias of the outcomes from three commercial assay systems.Methods: Seventy-two deoxyribonucleic acid (DNA) and 67 ribonucleic acid (RNA) samples were selected for methodological comparison among different systems. The DNA Quality Number (DQN) and RNA Quality Number (RQN) of BIOptic Qsep400, DNA Quality Score (DQS) and RNA Quality Score (RQS) of PerkinElmer Labchip GX Touch HT were separately compared with the DNA Integrity Number (DIN) and RNA Integrity Number (RINe) of the Agilent 4200 TapeStation according to Clinical and Laboratory Standards Institute (CLSI) guideline (EP09-A3).Results: The biases of the mean estimated between DQN and DIN, DQS and DIN both exceeded the acceptance criteria. The Passing-Bablok regression analysis between DQN and DIN, and the Deming regression analysis between DQS and DIN, showed the biases were both within the acceptance criteria, and the bias between DQN and DIN was smaller. For the comparisons of RQN and RINe, RQS and RINe, the regression analyses revealed the biases were both within the acceptance criteria. The bias of the mean estimated between RQS and RINe was outside of the acceptance criteria.Conclusions: There was a good comparability in nucleic acid integrity detection between BIOptic Qsep400 and PerkinElmer Labchip GX Touch HT with the Agilent 4200 TapeStation. However, the bias and linear correlations require more attention between systems.
引用
收藏
页码:624 / 630
页数:7