Ultrafast Measurement of Metformin in the Clinical Setting Using Probe Electrospray Ionization Mass Spectrometry

被引:1
|
作者
Griffeuille, Pauline [1 ]
El Balkhi, Souleiman [1 ]
Bodeau, Sandra [2 ]
Lamoureux, Fabien [3 ]
Marquet, Pierre [1 ,4 ]
Dulaurent, Sylvain [1 ]
Saint-Marcoux, Franck [1 ,5 ]
机构
[1] Limoges Univ Hosp, Dept Pharmacol & Toxicol, 2 Ave Martin Luther King, F-87042 Limoges, France
[2] Amiens Univ Hosp, Dept Pharmacol & Toxicol, 1 Rond Point Prof Christian Cabrol, F-80054 Amiens, France
[3] Rouen Univ Hosp, Dept Pharmacol & Toxicol, 37 Blvd Gambetta, F-76000 Rouen, France
[4] Univ Limoges, Pharmacol & Transplantat, INSERM, UMR1248, Rue Pr Bernard Descottes, F-87025 Limoges, France
[5] Fac Pharm, Dept Toxicol, 2 Rue Dr Marcland, F-87025 Limoges, France
关键词
LACTIC-ACIDOSIS; MORTALITY;
D O I
10.1093/jat/bkac034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metformin (MtF) is a treatment used for type 2 diabetes. Lactic acidosis (LA) is a frequent complication that can be either induced by or associated with elevated MtF plasma concentrations. When coupled with a mass spectrometry (MS) system, the probe electrospray ionization (PESI) method allows direct and rapid analysis of different types of matrices without pretreatment. In this study, we developed a PESI-MS method for the determination of MtF in plasma. We used a tandem mass spectrometer equipped with a PESI source in the reaction monitoring mode for the quantitation of MtF. MtF-D6 was chosen as the internal standard (IS), following an isotope dilution (ID) approach. The method was fully validated with six concentration levels (0.5-50 mg/L). The matrix effect was evaluated for each level, and the specificity was tested with a mix of potential co-medications. Using patient samples, the performance was compared with two classical LC-MS-MS and LC-diode array detector (DAD) methods used in external labs. Sample preparation consisted in mixing 10 mu L plasma in 1,000 mu L ethanol/ammonium formate buffer including MtF-D6 at a fixed concentration of 5 mg/L. The total run time was 0.31 min. ID gave satisfactory results of accuracy and precision (min-max: -12.1 to 15.8% and 1.0-17.1%, respectively). The matrix effect was fully corrected by the internal standard (bias < 1%). The specificity study also reported satisfactory results. Finally, in a representative group of 29 patients (55% with a concentration <5 mg/L, 38% with a concentration >5 mg/L and 7% not detected), we observed almost identical results when comparing LC-DAD and LC-MS-MS to PESI-MS (r(2) > 0.99). We propose a specific, sensitive, accurate and ultrafast solution for the measurement of MtF in patient plasma, with no sample preparation or calibration curve building. This could be helpful in a core lab when rapid diagnosis of LA is needed.
引用
下载
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [41] Aspartame degradation study using electrospray ionization mass spectrometry
    Pattanaargson, S
    Sanchavanakit, C
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (11) : 987 - 993
  • [42] Studies on the Biotransformation of Arctigenin Using Electrospray Ionization Mass Spectrometry
    Zhao Yufeng
    Song Fengrui
    Zhao Liping
    Liu Shuying
    ACTA CHIMICA SINICA, 2009, 67 (10) : 1123 - 1126
  • [43] Soft Ionization of Metallo-Mefenamic Using Electrospray Ionization Mass Spectrometry
    Abdelhamid, Hani Nasser
    Wu, Hui-Fen
    MASS SPECTROMETRY LETTERS, 2015, 6 (02) : 43 - 47
  • [44] Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry
    Wang, Zheng
    Zhu, Haijing
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 1957 - 1962
  • [46] Breast cancer diagnosis based on lipid profiling by probe electrospray ionization mass spectrometry
    Iwano, T.
    Yoshimura, K.
    Inoue, S.
    Odate, T.
    Ogata, K.
    Funatsu, S.
    Tanihata, H.
    Kondo, T.
    Ichikawa, D.
    Takeda, S.
    BRITISH JOURNAL OF SURGERY, 2020, 107 (06) : 632 - 635
  • [47] Probe electrospray ionization mass spectrometry-based rapid diagnosis of liver tumors
    Hakoda, Hiroyuki
    Kiritani, Sho
    Kokudo, Takashi
    Yoshimura, Kentaro
    Iwano, Tomohiko
    Tanimoto, Meguri
    Ishizawa, Takeaki
    Arita, Junichi
    Akamatsu, Nobuhisa
    Kaneko, Junichi
    Takeda, Sen
    Hasegawa, Kiyoshi
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2022, 37 (11) : 2182 - 2188
  • [48] USE OF ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY TO PROBE ANTISENSE PEPTIDE INTERACTIONS
    LOO, JA
    HOLSWORTH, DD
    ROOTBERNSTEIN, RS
    BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (01) : 6 - 12
  • [49] Determination of micelle mass by electrospray ionization mass spectrometry
    Nohara, D
    Kajiura, T
    Takeda, K
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04): : 489 - 493
  • [50] Measurement of hydrophobicity of peptides in electrospray ionization time-of-flight mass spectrometry
    Zhou Yue-Ming
    Wang Wei-Ping
    Liang Hua-Zheng
    Zhang Xie
    Chen Huan-Wen
    Chen Lan-Hui
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2006, 33 (10) : 942 - 947