Laser induced graphene electrochemical aptasensor based on tetrahedral DNA for ultrasensitive on-site detection of microcystin-LR

被引:16
|
作者
Wang, Yuan [1 ]
Li, Yuye [1 ]
Liu, Chang [1 ]
Dong, Na [1 ]
Liu, Dong [1 ]
You, Tianyan [1 ]
机构
[1] Jiangsu Univ, Sch Agr Engn, Key Lab Modern Agr Equipment & Technol, Minist Educ, Zhenjiang 212013, Jiangsu, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Microcystin-LR; Laser induced graphene; Electrochemical aptasensor; Tetrahedron DNA; On site detection; IMMUNOSENSOR;
D O I
10.1016/j.bios.2023.115610
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of accurate and reliable sensor for on-site detection of microcystin-LR (MC-LR), one of hazardous environmental pollutants, is highly required. Herein, a laser induced graphene (LIG)-based electrochemical aptasensor for sensitive on-site detection of MC-LR was reported. LIG electrode, the substrate of aptasensor, was prepared via thermal transfer with ethylene-vinyl acetate copolymer, and LIG acted as quasireference electrode to replace conventional Ag/AgCl electrode for better operability and robustness. LIG electrode provided large surface area to assemble tetrahedral DNA to absorb methylene blue (MB) for the signal amplification. For detection, the specific recognition of MC-LR with aptamer led to the stripping of tetrahedral DNA complex and further the decreased redox current of MB (IMB). Consequently, the fabricated aptasensor offered high analytical performance for MC-LR detection with a linear range of 1 x 10-2-1 x 105 pM and a detection limit of 3 x 10-3 pM, which was successfully used for water sample analysis with comparable reliability and accuracy of standard method. Furthermore, a portable detection platform by coupling of LIG-based electrochemical aptasensor with electrochemical workstation was constructed for on-site detection of MC-LR. This work offers a novel method for the on-site monitoring of MC-LR, which promotes the investigation of LIG-based electrochemical biosensing in the field of environmental analysis.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Self-assembled electroactive MOF-magnetic dispersible aptasensor enables ultrasensitive microcystin-LR detection in eutrophic water
    Wei, Tianxiang
    Zhang, Yinghao
    Wang, Huafeng
    Li, Huiming
    Fang, Ting
    Wang, Zhaoyin
    Dai, Zhihui
    CHEMICAL ENGINEERING JOURNAL, 2023, 466
  • [22] An autonomous driven DNA walker-based electrochemical aptasensor for on-site detection of Ochratoxin A
    Huang, Tongfu
    Wang, Mei
    Hong, Nian
    Cui, Hanfeng
    Fan, Qiqi
    Wei, Guobing
    Qin, Longshua
    Zhang, Jing
    Fan, Hao
    TALANTA, 2023, 252
  • [23] A rolling circle amplification signal-enhanced immunosensor for ultrasensitive microcystin-LR detection based on a magnetic graphene-functionalized electrode
    He, Zuyu
    Wei, Jie
    Gan, Cuifen
    Liu, Weipeng
    Liu, Yingju
    RSC ADVANCES, 2017, 7 (63): : 39906 - 39913
  • [24] Electrochemical immunosensor for ultrasensitive detection of microcystin-LR based on graphene-gold nanocomposite/functional conducting polymer/gold nanoparticle/ionic liquid composite film with electrodeposition
    Li Ruiyi
    Xia Qianfang
    Li Zaijun
    Sun Xiulan
    Liu Junkang
    BIOSENSORS & BIOELECTRONICS, 2013, 44 : 235 - 240
  • [25] A simple, supersensitive and highly selective electrochemical aptasensor for Microcystin-LR based on synergistic signal amplification strategy with graphene, DNase I enzyme and Au nanoparticles
    Liu, Meichuan
    Sun, Caiqin
    Wang, Guoqiang
    Wang, Yu
    Lu, Hanxing
    Shi, Huijie
    Zhao, Guohua
    ELECTROCHIMICA ACTA, 2019, 293 : 220 - 229
  • [26] A signal-amplification electrochemical aptasensor based on porous Pt nanotubes and tetrahedral DNA nanostructures for ultrasensitive detection of citrinin
    Tang, Shi
    He, Baoshan
    Yang, Jun
    Liu, Yao
    Liang, Ying
    Wang, Jinshui
    Jin, Huali
    Wei, Min
    Ren, Wenjie
    Suo, Zhiguang
    Xu, Yiwei
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 408
  • [27] Graphene and AuNPs based electrochemical aptasensor for ultrasensitive detection of hydroxylated polychlorinated biphenyl
    Yang, Kunhao
    Li, Zhongqiu
    Lv, Yueguang
    Yu, Chuyi
    Wang, Peilong
    Su, Xiaoou
    Wu, Li
    He, Yujian
    ANALYTICA CHIMICA ACTA, 2018, 1041 : 94 - 101
  • [28] Dual-Signal Integrated Aptasensor for Microcystin-LR Detection via In Situ Generation of Silver Nanoclusters Induced by Circular DNA Strand Displacement Reactions
    Zhao, Qinqin
    Gao, Zhongfeng
    Liu, Xuejing
    Song, Xianzhen
    Wu, Dan
    Ma, Hongmin
    Ren, Xiang
    Li, Yueyun
    Wei, Qin
    ANALYTICAL CHEMISTRY, 2023, 95 (38) : 14317 - 14323
  • [29] Competitive smartphone-based portable electrochemical aptasensor system based on an MXene/cDNA-MB probe for the determination of Microcystin-LR
    Fan, Liang
    Huang, Jinhui Jeanne
    Liao, Jianjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 369
  • [30] Fluorescence resonance energy transfer based quantum dot-Aptasensor for the selective detection of microcystin-LR in eutrophic water
    Lee, Eun-Hee
    Son, Ahjeong
    CHEMICAL ENGINEERING JOURNAL, 2019, 359 : 1493 - 1501