Laser induced graphene electrochemical aptasensor based on tetrahedral DNA for ultrasensitive on-site detection of microcystin-LR

被引:16
|
作者
Wang, Yuan [1 ]
Li, Yuye [1 ]
Liu, Chang [1 ]
Dong, Na [1 ]
Liu, Dong [1 ]
You, Tianyan [1 ]
机构
[1] Jiangsu Univ, Sch Agr Engn, Key Lab Modern Agr Equipment & Technol, Minist Educ, Zhenjiang 212013, Jiangsu, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Microcystin-LR; Laser induced graphene; Electrochemical aptasensor; Tetrahedron DNA; On site detection; IMMUNOSENSOR;
D O I
10.1016/j.bios.2023.115610
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of accurate and reliable sensor for on-site detection of microcystin-LR (MC-LR), one of hazardous environmental pollutants, is highly required. Herein, a laser induced graphene (LIG)-based electrochemical aptasensor for sensitive on-site detection of MC-LR was reported. LIG electrode, the substrate of aptasensor, was prepared via thermal transfer with ethylene-vinyl acetate copolymer, and LIG acted as quasireference electrode to replace conventional Ag/AgCl electrode for better operability and robustness. LIG electrode provided large surface area to assemble tetrahedral DNA to absorb methylene blue (MB) for the signal amplification. For detection, the specific recognition of MC-LR with aptamer led to the stripping of tetrahedral DNA complex and further the decreased redox current of MB (IMB). Consequently, the fabricated aptasensor offered high analytical performance for MC-LR detection with a linear range of 1 x 10-2-1 x 105 pM and a detection limit of 3 x 10-3 pM, which was successfully used for water sample analysis with comparable reliability and accuracy of standard method. Furthermore, a portable detection platform by coupling of LIG-based electrochemical aptasensor with electrochemical workstation was constructed for on-site detection of MC-LR. This work offers a novel method for the on-site monitoring of MC-LR, which promotes the investigation of LIG-based electrochemical biosensing in the field of environmental analysis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] All in laser-induced graphene to fabricate the electrochemical biosensor for on-site detection of microcystin-LR
    Chen, Zuo
    Dong, Na
    Wang, Yuan
    Li, Yuqing
    Li, Wenjia
    Liu, Dong
    You, Tianyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 419
  • [2] CRISPR-Cas12a-Based Aptasensor for On-Site and Highly Sensitive Detection of Microcystin-LR in Freshwater
    Kang, Yuliang
    Su, Gaoxing
    Yu, Yanyan
    Cao, Jiajia
    Wang, Jiali
    Yan, Bing
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (07) : 4101 - 4110
  • [3] A novel SERS-based aptasensor for ultrasensitive sensing of microcystin-LR
    He, Deyun
    Wu, Zhengzong
    Cui, Bo
    Jin, Zhengyu
    FOOD CHEMISTRY, 2019, 278 : 197 - 202
  • [4] Nanobiochar paper based electrochemical immunosensor for fast and ultrasensitive detection of microcystin-LR
    Yao, Lan
    He, Lingzhi
    Yang, Yuesuo
    Zhang, Yu
    Liu, Zairan
    Liang, Lina
    Piao, Yunxian
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 750 (750)
  • [5] Electrochemical detection of microcystin-LR based on its deleterious effect on DNA
    Zhang, Keke
    Ma, Huiying
    Yan, Ping
    Tong, Wenjun
    Huang, Xiaohua
    Chen, David D. Y.
    TALANTA, 2018, 185 : 405 - 410
  • [6] A highly sensitive electrochemical aptasensor for detection of microcystin-LR based on a dual signal amplification strategy
    Liu, Xiaoqiang
    Tang, Yunfei
    Liu, Peipei
    Yang, Liwei
    Li, Lele
    Zhang, Qingyou
    Zhou, Yanmei
    Khan, Md. Zaved Hossain
    ANALYST, 2019, 144 (05) : 1671 - 1678
  • [7] A label-free electrochemical immunosensor based on multi-functionalized graphene oxide for ultrasensitive detection of microcystin-LR
    YunXia Hu
    Fang Shang
    Yuan Liu
    Sui Wang
    Yufang Hu
    Zhiyong Guo
    Chemical Papers, 2018, 72 : 71 - 79
  • [8] A label-free electrochemical immunosensor based on multi-functionalized graphene oxide for ultrasensitive detection of microcystin-LR
    Hu, YunXia
    Shang, Fang
    Liu, Yuan
    Wang, Sui
    Hu, Yufang
    Guo, Zhiyong
    CHEMICAL PAPERS, 2018, 72 (01) : 71 - 79
  • [9] A novel fluorescent aptasensor for ultrasensitive detection of microcystin-LR based on single-walled carbon nanotubes and dapoxyl
    Taghdisi, Seyed Mohammad
    Danesh, Noor Mohammad
    Ramezani, Mohammad
    Ghows, Narjes
    Shaegh, Seyed Ali Mousavi
    Abnous, Khalil
    TALANTA, 2017, 166 : 187 - 192
  • [10] A graphene and multienzyme functionalized carbon nanosphere-based electrochemical immunosensor for microcystin-LR detection
    Zhao, Huimin
    Tian, Junping
    Quan, Xie
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 103 : 38 - 44