A 136-GΩ Input-Impedance Active Electrode for Non-Contact Biopotential Signals Monitoring

被引:0
|
作者
Qu, Tianxiang [1 ]
Wang, Peizhuo [1 ,2 ]
Lei, Liangbo [1 ]
Hong, Zhiliang [1 ]
Xu, Jiawei [1 ]
机构
[1] Fudan Univ, State Key Lab Integrated Chips & Syst, Shanghai 201203, Peoples R China
[2] Analog Devices Inc, Shanghai 200021, Peoples R China
关键词
Active electrode (AE); calibration; capacitor scaling; input-impedance boosting; non-contact; positive feedback; ultra-high input impedance; AMPLIFIER;
D O I
10.1109/JSSC.2023.3284524
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article describes an ultra-high input-impedance active electrode (AE) circuit and the system to sense biopotential signals through a capacitively coupled interface. Various techniques from both circuit and system aspects are used to eliminate the input parasitic capacitance of the AE. On-chip parasitic capacitance is compensated by an auto-calibrated positive feedback loop (PFL) without applying any reference signal. A capacitor down-scaling technique combined with SAR-assisted PFL calibration enables femtofarad-level resolution of the capacitor array, alleviating the practical constraints of the conventional PFL to implement a small capacitor below 10 fF. Besides, a dummy input structure ensures that the pad and electrostatic discharge (ESD) capacitances are also canceled by the PFL, while off-chip parasitic capacitance on the printed circuit board (PCB) is nulled by active shielding. Fabricated in a standard 0.18-mu m 1P6M CMOS process, the AE achieves an ultra-high input impedance of 136 G Omega at 60 Hz (average of 10 samples). This is equivalent to an input capacitance of 19.5 fF and corresponds to a 2.7x-68x improvement over the state-of-the-art. The AE exhibits an input signal range of 700 mV(pp) and an input-referred noise of 0.72 mu V-rms (0.5-100 Hz) while consuming 10.46 mu W from a 1.2-V supply. Each AE integrates an IC and a 3-cm(2) copper electrode on the PCB, and the wearable system prototypes successfully measured high-quality electrocardiogram (ECG) and electroencephalogram (EEG) signals from test subjects through capacitively coupled interfaces.
引用
下载
收藏
页码:364 / 374
页数:11
相关论文
共 29 条
  • [21] Non-contact monitoring of extra-cellular field potentials with a multi-electrode array
    Sharf, Tal
    Hansma, Paul K.
    Hari, Mukund A.
    Kosik, Kenneth S.
    LAB ON A CHIP, 2019, 19 (08) : 1448 - 1457
  • [22] Non-contact electrocardiogram measuring method based on capacitance coupling electrodes with ultra-high input impedance
    Li, Jiangtao
    Wang, Yifeng
    Li, Chenjie
    Xu, Zhengyi
    Zhao, Zheng
    Raza, Syed Ali
    Wang, Yangang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (03):
  • [23] DEVELOPMENT OF A LASER-BASED OPTICAL ELECTRODE FOR REAL TIME NON-CONTACT MONITORING OF NERVE ACTIVITY
    Islam, M. Shahidul
    Haque, M. Rezuanul
    Oh, Christian
    Wang, Yan
    Park, B. Hyle
    LASERS IN SURGERY AND MEDICINE, 2012, 44 : 40 - 41
  • [24] A 250MΩ Input Impedance a-IGZO Front-End for Biosignal Acquisition from Non-Contact Electrodes
    van Oosterhout, Kyle
    Timmermans, Martijn
    Fattori, Marco
    Cantatore, Eugenio
    2024 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, ISCAS 2024, 2024,
  • [25] A non-contact triboelectric vibration sensor with a spiral floating electrode structure for low-frequency vibration monitoring
    Li, Yuan
    Li, Qichao
    Ma, Xiongchao
    Li, Xingjia
    Guo, Yiping
    Nano Energy, 2025, 133
  • [26] Flexible Electrodes-Based Smart Mattress for Monitoring Physiological Signals of Heart and Autonomic Nerves in a Non-Contact Way
    Peng, Shun
    Xu, Ke
    Bao, Shenjie
    Yuan, Yafei
    Dai, Chenyun
    Chen, Wei
    IEEE SENSORS JOURNAL, 2021, 21 (01) : 6 - 15
  • [27] Flexible MXene/bamboo cellulose fiber/TPU membrane based humidity sensor for non-contact monitoring of human physiological signals
    Guochong Gong
    Wang Chen
    Ran Yan
    Xiaolin Ran
    Wenfeng Qin
    Chuanyong Huang
    Xin Zhao
    Cellulose, 2025, 32 (2) : 1089 - 1104
  • [28] A 9.2-gram Fully-Flexible Wireless Dry-Electrode Headband for Non-Contact Artifact-Resilient EEG Monitoring and Programmable Diagnostics
    Dabbaghian, Alireza
    Yousefi, Tayebeh
    Shafia, Pooria
    Fatmi, Syyeda Zainab
    Kassiri, Hossein
    2019 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2019,
  • [29] Non-contact monitoring of human heartbeat signals using mm-wave frequency-modulated continuous-wave radar under low signal-to-noise ratio conditions
    Zhang, Wenyu
    Li, Gang
    Wang, Zetao
    Wu, Hao
    IET RADAR SONAR AND NAVIGATION, 2022, 16 (03): : 456 - 469