A 136-GΩ Input-Impedance Active Electrode for Non-Contact Biopotential Signals Monitoring

被引:0
|
作者
Qu, Tianxiang [1 ]
Wang, Peizhuo [1 ,2 ]
Lei, Liangbo [1 ]
Hong, Zhiliang [1 ]
Xu, Jiawei [1 ]
机构
[1] Fudan Univ, State Key Lab Integrated Chips & Syst, Shanghai 201203, Peoples R China
[2] Analog Devices Inc, Shanghai 200021, Peoples R China
关键词
Active electrode (AE); calibration; capacitor scaling; input-impedance boosting; non-contact; positive feedback; ultra-high input impedance; AMPLIFIER;
D O I
10.1109/JSSC.2023.3284524
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article describes an ultra-high input-impedance active electrode (AE) circuit and the system to sense biopotential signals through a capacitively coupled interface. Various techniques from both circuit and system aspects are used to eliminate the input parasitic capacitance of the AE. On-chip parasitic capacitance is compensated by an auto-calibrated positive feedback loop (PFL) without applying any reference signal. A capacitor down-scaling technique combined with SAR-assisted PFL calibration enables femtofarad-level resolution of the capacitor array, alleviating the practical constraints of the conventional PFL to implement a small capacitor below 10 fF. Besides, a dummy input structure ensures that the pad and electrostatic discharge (ESD) capacitances are also canceled by the PFL, while off-chip parasitic capacitance on the printed circuit board (PCB) is nulled by active shielding. Fabricated in a standard 0.18-mu m 1P6M CMOS process, the AE achieves an ultra-high input impedance of 136 G Omega at 60 Hz (average of 10 samples). This is equivalent to an input capacitance of 19.5 fF and corresponds to a 2.7x-68x improvement over the state-of-the-art. The AE exhibits an input signal range of 700 mV(pp) and an input-referred noise of 0.72 mu V-rms (0.5-100 Hz) while consuming 10.46 mu W from a 1.2-V supply. Each AE integrates an IC and a 3-cm(2) copper electrode on the PCB, and the wearable system prototypes successfully measured high-quality electrocardiogram (ECG) and electroencephalogram (EEG) signals from test subjects through capacitively coupled interfaces.
引用
收藏
页码:364 / 374
页数:11
相关论文
共 28 条
  • [1] A 136GΩ-Input-Impedance Active Electrode for Non-Contact ECG Using Auto-Calibrated. Positive Feedback and Capacitance Scaling in Femtofarad Resolution
    Wang, Peizhuo
    Qu, Tianxiang
    Lei, Liangbo
    Hong, Zhiliang
    Xu, Jiawei
    [J]. ESSCIRC 2022- IEEE 48TH EUROPEAN SOLID STATE CIRCUITS CONFERENCE (ESSCIRC), 2022, : 433 - 436
  • [2] A 400 GΩ Input-Impedance Active Electrode for Non-Contact Capacitively Coupled ECG Acquisition With Large Linear-Input-Range and High CM-Interference-Tolerance
    Chen, Mingyi
    Chun, Ho Sung
    Castro, Ivan Dario
    Torfs, Tom
    Lin, Qiuyang
    van Hoof, Chris
    Wang, Guoxing
    Lian, Yong
    van Helleputte, Nick
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (02) : 376 - 386
  • [3] A 400GΩ input-impedance, 220mVpp linear-input-range, 2.8Vpp CM-interference -tolerant active electrode for non-contact capacitively coupled ECG acquisition
    Chen, Mingyi
    Castro, Ivan Dario
    Lin, Qiuyang
    Torfs, Tom
    Tavernier, Filip
    Van Hoof, Chris
    Van Helleputte, Nick
    [J]. 2018 IEEE SYMPOSIUM ON VLSI CIRCUITS, 2018, : 129 - 130
  • [4] Relative measurement of differential electrode impedance for contact monitoring in a biopotential amplifier
    Yoo, Sun K.
    [J]. INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2007, 5 (05) : 601 - 605
  • [5] Design and Evaluation of A Non-Contact Wireless Biopotential Monitoring System with Motion Artifacts
    Li, Xian
    Sun, Ye
    [J]. 2017 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL & HEALTH INFORMATICS (BHI), 2017, : 69 - 72
  • [6] Integrated Ultra-High Impedance Front-end for Non-contact Biopotential Sensing
    Chi, Yu M.
    Maier, Christoph
    Cauwenberghs, Gert
    [J]. 2011 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2011, : 456 - 459
  • [7] Wearable Monitoring System Based on Non-Contact Electrode
    Liu, Jihong
    Chen, Yuanjin
    Wu, Qilong
    Zhou, Yanfeng
    Qiao, Tianrun
    Sun, Bangke
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 33 - 34
  • [8] A 1.62 μW 8-Channel Ultra-High Input Impedance EEG Amplifier for Dry and Non-Contact Biopotential Recording Applications
    Nasserian, Mahshid
    Peiravi, Ali
    Moradi, Farshad
    [J]. 2016 IFIP/IEEE INTERNATIONAL CONFERENCE ON VERY LARGE SCALE INTEGRATION (VLSI-SOC), 2016,
  • [9] An Interdigitated Non-Contact ECG Electrode for Impedance Compensation and Signal Restoration
    Lin, Jeng-Hau
    Liu, Hao
    Liu, Chia-Hung
    Lam, Phillip
    Pan, Gung-Yu
    Zhuang, Hao
    Kang, Ilgweon
    Mercier, Patrick P.
    Cheng, Chung-Kuan
    [J]. 2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 544 - 547
  • [10] Non-contact biopotential measurement from the human body using a low-impedance charge amplifier
    Smith, WJ
    LaCourse, JR
    [J]. PROCEEDINGS OF THE IEEE 30TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2004, : 31 - 32