Design, manufacturing, and testing of phase-induced amplitude apodization and phase-shifting optics for segmented telescopes

被引:2
|
作者
Martinez, P. [1 ]
Beaulieu, M. [1 ]
Gouvret, C. [1 ]
Spang, A. [1 ]
Marcotto, A. [1 ]
Guyon, O. [2 ,3 ,4 ]
Tisserand, S. [5 ]
Sauget, V. [5 ]
Gautier, S. [5 ]
Le Duigou, J. M. [6 ]
机构
[1] Univ Cote Azur, Observ Cote Azur, CNRS, Lab Lagrange, Nice, France
[2] Natl Inst Nat Sci, Astrobiol Ctr, 2-21-1 Osawa, Mitaka, Tokyo, Japan
[3] Univ Arizona, Steward Observ, Tucson, AZ 85721 USA
[4] Natl Inst Nat Sci, Natl Astron Observ Japan, Subaru Telescope, Hilo, HI 96720 USA
[5] Silios Technol, Rue Gaston Imbert Prolonge,ZI Peynier Rousset, F-13790 Peynier, France
[6] Ctr Natl Etud Spatiales, 18 Ave Edouard Belin, F-31401 Toulouse 9, France
关键词
instrumentation: high angular resolution; techniques: high angular resolution; telescopes; HIGH-CONTRAST; IMPACT; LIMITS; LYOT;
D O I
10.1051/0004-6361/202347337
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Context. The phase-induced amplitude apodization complex mask coronagraph (PIAACMC) is a coronagraph architecture for the direct detection of extrasolar planets. The PIAACMC can achieve close to the theoretical performance limit at small angular sepa-rations. The concept is a high-performance PIAA-based coronagraph that is sufficiently versatile to be designed for next-generation segmented and obscured telescope apertures.Aims. We present key elements of the design and manufacture of a PIAACMC for the segmented pupil experiment for exoplanet detection (SPEED) testbed. The primary components of a PIAACMC system are the PIAA optics and the complex phase-shifting focal plane mask (FPM). The most challenging part of the system to model is the error on the manufacturing of the two PIAA mirrors.Methods. In this paper, we describe the design and manufacturing of the FPM and moderate-sag PIAA optics using photolithography and etching. We present the design and fabrication of the PIAACMC, along with metrology, and an initial assessment of the PIAACMC optics efficiency.Results. Errors in the fabricated component profiles degrade the overall performance. We show that the depth errors involved are of a few tens of nanometers and a few hundred nanometers for the FPM and PIAA optics, respectively. The metrological and individual per not sign formance analysis of the FPM and PIAA optics provides us with an in-depth understanding of these optical quality of the components, manufacturing error propagation, and the effects of these on performance. Because the deformable mirror (DM) location is critical in a PIAA system, we show that despite the pupil remapping effect of the PIAA optics, a dual-DM wavefront control and shaping system architecture optimized for short angular separations is operating adequately to compensate for manufacturing errors and for the dark zone generated in the focal plane.Conclusions. Because the errors involved are comparable to the wavefront error on the optics, wavefront control can compensate for them. Our measurements provide reliable models that, when used in simulations, allow us to refine component specification given the manufacturing errors at the raw coronagraphic performance level as well as after wavefront control and shaping.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Comparison and Correction of Errors Caused by Radial Phase-Shifting Nonuniformity of Test Optics in Multi-Step Phase-Shifting
    Gao Fen
    Ni Jinping
    Li Bing
    Tian Ailing
    ACTA OPTICA SINICA, 2018, 38 (04)
  • [32] Near-field amplitude and phase recovery using phase-shifting interferometry
    Deutsch, B.
    Hillenbrand, R.
    Novotny, L.
    OPTICS EXPRESS, 2008, 16 (02): : 494 - 501
  • [33] Phase-shifting interferometry with a reflective diffraction grating for adaptive optics
    Garoi, F.
    Logofatu, P. C.
    Apostol, D.
    Udrea, C.
    ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES VI, 2012, 8411
  • [34] Phase-Shifting Fringe Projection System Using Freeform Optics
    Zwick, Susanne
    Kuehmstedt, Peter
    Notni, Gunther
    OPTICAL FABRICATION, TESTING, AND METROLOGY IV, 2011, 8169
  • [35] Design of a 24'' phase-shifting Fizeau interferometer
    Ai, CY
    Knowlden, B
    Lamb, J
    LASER INTERFEROMETRY VIII: TECHNIQUES AND ANALYSIS, 1996, 2860 : 398 - 403
  • [36] DESIGN AND ASSESSMENT OF SYMMETRICAL PHASE-SHIFTING ALGORITHMS
    LARKIN, KG
    OREB, BF
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1992, 9 (10) : 1740 - 1748
  • [37] DESIGN COMPLEX PHASE-SHIFTING AND MATCHING NETWORKS
    SADOWSKI, B
    MICROWAVES & RF, 1994, 33 (13) : 131 - &
  • [38] Design of 24" phase-shifting Fizeau interferometer
    Ai, CY
    Knowlden, R
    Lamb, J
    OPTICAL MANUFACTURING AND TESTING II, 1997, 3134 : 447 - 455
  • [39] Phase-shifting interferometry by wave amplitude modulation: General case
    Meneses-Fabian, Cruz
    Rivera-Ortega, Uriel
    OPTICS AND LASERS IN ENGINEERING, 2012, 50 (07) : 905 - 909
  • [40] An Amplitude Regulation for Gyroscope Drive Loops based on Phase-Shifting
    Northemann, T.
    Ziegler, A.
    Maurer, M.
    Manoli, Y.
    2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 3268 - 3271