Dosimetric Comparison of Helical Tomotherapy and HyperArc Treatment Plans for Angiosarcoma of the Scalp

被引:0
|
作者
Inui, Shoki [1 ,2 ]
Takahashi, Yutaka [2 ]
Ueda, Yoshihiro [1 ]
Ohira, Shingo [1 ]
Washio, Hayate [3 ]
Ono, Shunsuke [1 ]
Miyazaki, Masayoshi [1 ]
Nishio, Teiji [2 ]
Koizumi, Masahiko [2 ]
Konishi, Koji [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Grad Sch Med, Dept Med Phys & Engn, Osaka, Japan
[3] Osaka Int Canc Inst, Dept Radiol, Osaka, Japan
关键词
HyperArc; helical tomotherapy; volumetric-modulated arc therapy; total scalp irradiation; angiosarcoma of the scalp; RADIATION-THERAPY; IRRADIATION;
D O I
10.21873/anticanres.16479
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Aim: Angiosarcoma of the scalp (AS) is a rare tumor that has often been treated by total scalp irradiation (TSI). TSI has technical and dosimetric challenges. This study aimed to compare the dosimetric performance of helical tomotherapy (HT) plans with that of HyperArc (HA) plans for TSI in AS. Patients and Methods: A planning study was conducted for 11 patients with AS (70 Gy/35 fr). HT and HA planning was performed using TomoHDA and TrueBeam Edge systems, respectively. The performance of three different plans were compared: HT, HA, and HA with half-field beams (HF-HA). The dose distribution and dosimetric parameters for each plan were evaluated. Results: All constraint parameters for the target and organs at risk (OARs) met the goals within acceptable limits for the three techniques. The HA and HF-HA plans provided significantly lower mean brain dose (12.46 +/- 2.48 Gy and 8.02 +/- 1.48 Gy) than did the HT plan (17.59 +/- 3.47 Gy). The doses receiving 0.1 cc of the volume for brainstem and chiasm were significantly lower in the HA and HF-HA plans than those in the HT plan. The HA and HF-HA plans provided a shorter beam-on time (155 +/- 3 s and 181 +/- 14 s) than did the HT plan (962 +/- 221 s). Conclusion: The HA plan provided significantly better OARs sparing than the HT plan for TSI in AS and had an advantage to using half-field beams.
引用
收藏
页码:3079 / 3087
页数:9
相关论文
共 50 条
  • [41] Dosimetric comparison among cyberknife, helical tomotherapy and VMAT for hypofractionated treatment in localized prostate cancer
    Serra, Marcello
    Ametrano, Gianluca
    Borzillo, Valentina
    Quarto, Maria
    Muto, Matteo
    Di Franco, Rossella
    Federica, Savino
    Loffredo, Filomena
    Paolo, Muto
    [J]. MEDICINE, 2020, 99 (50) : E23574
  • [42] Application of Helical Tomotherapy for the Treatment of a Right Atrium Angiosarcoma: A Case Report
    Franceschini, Davide
    Scotti, Vieri
    Simontacchi, Gabriele
    Meattini, Icro
    Paiar, Fabiola
    Greto, Daniela
    Bonomo, Pierluigi
    Franzese, Ciro
    Di Cataldo, Vanessa
    Pallotta, Stefania
    Biti, Giampaolo
    [J]. TUMORI JOURNAL, 2013, 99 (05): : e233 - e236
  • [43] Dosimetric comparison of helical tomotherapy and stereotactic radiotherapy for single brain lesions
    Reinartz, G.
    Ernst, I
    Willich, N.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 35 - 35
  • [44] Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy
    Lobb, Eric
    [J]. MEDICAL DOSIMETRY, 2014, 39 (01) : 93 - 97
  • [45] Dosimetric and clinical review of helical tomotherapy
    Rong, Yi
    Welsh, James S.
    [J]. EXPERT REVIEW OF ANTICANCER THERAPY, 2011, 11 (02) : 309 - 320
  • [46] Dosimetric Comparison of Stereotactic Body Radiation Therapy Plans With Volumetric Arc Therapy, Helical Tomotherapy, and Raystation for Liver Metastasis
    Onal, C.
    Efe, E.
    Yildirim, B. Akkus
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E177 - E178
  • [47] Dosimetric Comparison of Helical Tomotherapy against Protons in Treating the Prostate Alone
    Lewis, B. E.
    Yue, N. J.
    Millevoi, R.
    Kim, S.
    Louis, D.
    Li, Z.
    Mendenhall, N. P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S705 - S706
  • [48] TOMOTHERAPY, 3D OR IMRT: COMPARISON OF CALCULATED DOSIMETRIC PLANS
    Lacombe, C.
    Letenneur, G.
    Moeckli, R.
    Mirimanoff, R. O.
    Pachoud, M.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 (11) : 631 - 631
  • [49] Dosimetric comparison between Helical Tomotherapy and IMRT for Bilateral Breast Cancer
    Wang, M. H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S621 - S621
  • [50] A successful approach for angiosarcoma of the scalp using helical tomotherapy and customized surface mold brachytherapy A case report
    Suzuki, Gen
    Masui, Koji
    Watanabe, Sho
    Yamazaki, Hideya
    Takenaka, Tadashi
    Asai, Jun
    Maruyama, Ayano
    Yamada, Kei
    [J]. MEDICINE, 2021, 100 (49)