Dosimetric Comparison of Helical Tomotherapy and HyperArc Treatment Plans for Angiosarcoma of the Scalp

被引:0
|
作者
Inui, Shoki [1 ,2 ]
Takahashi, Yutaka [2 ]
Ueda, Yoshihiro [1 ]
Ohira, Shingo [1 ]
Washio, Hayate [3 ]
Ono, Shunsuke [1 ]
Miyazaki, Masayoshi [1 ]
Nishio, Teiji [2 ]
Koizumi, Masahiko [2 ]
Konishi, Koji [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Grad Sch Med, Dept Med Phys & Engn, Osaka, Japan
[3] Osaka Int Canc Inst, Dept Radiol, Osaka, Japan
关键词
HyperArc; helical tomotherapy; volumetric-modulated arc therapy; total scalp irradiation; angiosarcoma of the scalp; RADIATION-THERAPY; IRRADIATION;
D O I
10.21873/anticanres.16479
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Aim: Angiosarcoma of the scalp (AS) is a rare tumor that has often been treated by total scalp irradiation (TSI). TSI has technical and dosimetric challenges. This study aimed to compare the dosimetric performance of helical tomotherapy (HT) plans with that of HyperArc (HA) plans for TSI in AS. Patients and Methods: A planning study was conducted for 11 patients with AS (70 Gy/35 fr). HT and HA planning was performed using TomoHDA and TrueBeam Edge systems, respectively. The performance of three different plans were compared: HT, HA, and HA with half-field beams (HF-HA). The dose distribution and dosimetric parameters for each plan were evaluated. Results: All constraint parameters for the target and organs at risk (OARs) met the goals within acceptable limits for the three techniques. The HA and HF-HA plans provided significantly lower mean brain dose (12.46 +/- 2.48 Gy and 8.02 +/- 1.48 Gy) than did the HT plan (17.59 +/- 3.47 Gy). The doses receiving 0.1 cc of the volume for brainstem and chiasm were significantly lower in the HA and HF-HA plans than those in the HT plan. The HA and HF-HA plans provided a shorter beam-on time (155 +/- 3 s and 181 +/- 14 s) than did the HT plan (962 +/- 221 s). Conclusion: The HA plan provided significantly better OARs sparing than the HT plan for TSI in AS and had an advantage to using half-field beams.
引用
收藏
页码:3079 / 3087
页数:9
相关论文
共 50 条
  • [1] Helical tomotherapy of the entire Scalp and ipsilateral Lymphatics in Angiosarcoma of the Scalp
    Krause, S.
    Sterzing, F.
    Hantschke, M.
    Lissner, S.
    Oetzel, D.
    Herfarth, K.
    Debus, J.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 93 - 94
  • [2] Dosimetric effect of rotational variation on helical tomotherapy treatment plans
    Staten, R.
    Langen, K.
    Shah, A.
    Meeks, S.
    Kupelian, P.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2441 - 2441
  • [3] Dosimetric Effect of Target Degradation On Helical TomoTherapy Treatment Plans
    Staton, R.
    Langen, K.
    Meeks, S.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2919 - +
  • [4] A dosimetric comparison of five brain tumor treatment plans for treatment with helical Tomotherapy and Gamma Knife
    Grossheim, Linda
    Jursinic, Paul
    [J]. NEURO-ONCOLOGY, 2007, 9 (04) : 583 - 583
  • [5] Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
    Mizuno, Tomoki
    Tomita, Natsuo
    Takaoka, Taiki
    Tomida, Masashi
    Fukuma, Hiroshi
    Tsuchiya, Takahiro
    Shibamoto, Yuta
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [6] Dosimetric Comparison of Dynamic Trajectory Radiotherapy, HyperArc and VMAT Treatment Plans
    Fix, M. K.
    Mueller, S.
    Volken, W.
    Terribilini, D.
    Frei, D.
    Elicin, O.
    Aebersold, D. M.
    Manser, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E295 - E295
  • [7] Dosimetric verification of treatment plans for TBI/TMI on helical tomotherapy.
    Dubiel, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1671 - S1672
  • [8] Dosimetric verification of helical tomotherapy for total scalp irradiation
    Hardcastle, Nicholas
    Soisson, Emilie
    Metcalfe, Peter
    Rosenfeld, Anatoly B.
    Tome, Wolfgang A.
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 5061 - 5068
  • [9] DOSIMETRIC COMPARISON OF HELICAL TOMOTHERAPY AND LINAC-IMRT TREATMENT PLANS FOR HEAD AND NECK CANCER PATIENTS
    Zhang, Xin
    Penagaricano, Jose
    Moros, Eduardo G.
    Corry, Peter M.
    Yan, Yulong
    Ratanatharathorn, Vaneerat
    [J]. MEDICAL DOSIMETRY, 2010, 35 (04) : 264 - 268
  • [10] Dosimetric comparison of TomoDirect, Helical Tomotherapy, and VMAT for postmastectomy treatment
    Nobnop, W.
    Chitapanarux, I.
    Phakoetsuk, P.
    Tippanya, D.
    Khamchompoo, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 141 : S61 - S61