Accuracy of automated machine learning in classifying retinal pathologies from ultra-widefield pseudocolour fundus images

被引:33
|
作者
Antaki, Fares [1 ,2 ]
Coussa, Razek Georges [3 ]
Kahwati, Ghofril [4 ]
Hammamji, Karim [1 ]
Sebag, Mikael [1 ]
Duval, Renaud [2 ]
机构
[1] Ctr Hosp Univ Montreal CHUM, Dept Ophthalmol, Montreal, PQ, Canada
[2] Hop Maisonneuve Rosemt CUO HMR, Dept Ophthalmol, Montreal, PQ, Canada
[3] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[4] Ecole Technol Super ETS, Dept Elect Engn, Montreal, PQ, Canada
关键词
retina; imaging; HEALTH-CARE PROFESSIONALS; ARTIFICIAL-INTELLIGENCE;
D O I
10.1136/bjophthalmol-2021-319030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims Automated machine learning (AutoML) is a novel tool in artificial intelligence (AI). This study assessed the discriminative performance of AutoML in differentiating retinal vein occlusion (RVO), retinitis pigmentosa (RP) and retinal detachment (RD) from normal fundi using ultra-widefield (UWF) pseudocolour fundus images. Methods Two ophthalmologists without coding experience carried out AutoML model design using a publicly available image data set (2137 labelled images). The data set was reviewed for low-quality and mislabeled images and then uploaded to the Google Cloud AutoML Vision platform for training and testing. We designed multiple binary models to differentiate RVO, RP and RD from normal fundi and compared them to bespoke models obtained from the literature. We then devised a multiclass model to detect RVO, RP and RD. Saliency maps were generated to assess the interpretability of the model. Results The AutoML models demonstrated high diagnostic properties in the binary classification tasks that were generally comparable to bespoke deep-learning models (area under the precision-recall curve (AUPRC) 0.921-1, sensitivity 84.91%-89.77%, specificity 78.72%-100%). The multiclass AutoML model had an AUPRC of 0.876, a sensitivity of 77.93% and a positive predictive value of 82.59%. The per-label sensitivity and specificity, respectively, were normal fundi (91.49%, 86.75%), RVO (83.02%, 92.50%), RP (72.00%, 100%) and RD (79.55%,96.80%). Conclusion AutoML models created by ophthalmologists without coding experience can detect RVO, RP and RD in UWF images with very good diagnostic accuracy. The performance was comparable to bespoke deep-learning models derived by AI experts for RVO and RP but not for RD.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 50 条
  • [31] Estimation of Visual Function Using Deep Learning From Ultra-Widefield Fundus Images of Eyes With Retinitis Pigmentosa
    Nagasato, Daisuke
    Sogawa, Takahiro
    Tanabe, Mao
    Tabuchi, Hitoshi
    Numa, Shogo
    Oishi, Akio
    Ikeda, Hanako Ohashi
    Tsujikawa, Akitaka
    Maeda, Tadao
    Takahashi, Masayo
    Ito, Nana
    Miura, Gen
    Shinohara, Terumi
    Egawa, Mariko
    Mitamura, Yoshinori
    JAMA OPHTHALMOLOGY, 2023, 141 (04) : 305 - 313
  • [32] A review of concentric macular rings seen on scanning laser ophthalmoscopy ultra-widefield pseudocolour reflectance images
    De Silva, Isuru Godakandage Isuru Ravihansa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [33] Automated Diagnosis of Retinal Neovascularization Pathologies from Color Retinal Fundus Images
    Boukadida, Rahma
    Elloumi, Yaroub
    Kachouri, Rostom
    Ben Abdallah, Asma
    Bedoui, Mohamed Hedi
    ADVANCES IN COMPUTER GRAPHICS, CGI 2022, 2022, 13443 : 451 - 462
  • [34] Screening for hypertension using retinal vascular calibre in ultra-widefield fundus imaging
    Robertson, Gavin
    Fleming, Alan
    Williams, Michelle C.
    Trucco, Emanuele
    Quinn, Nicola
    Hogg, Ruth E.
    Makay, Gareth J.
    Kee, Frank
    Young, Ian S.
    Pellegrini, Enrico
    Newby, David E.
    van Beek, Edwin J. R.
    Peto, Tunde
    Dhillon, Baljean
    van Hemert, Jano
    MacGillivray, Tom
    JOURNAL OF HUMAN HYPERTENSION, 2018, 32 (10) : 718 - 719
  • [35] Automated Quality Assessment of Ultra-Widefield Fluorescein Angiography Images using Deep Learning
    Li, Henry
    Abraham, Joseph R.
    Hach, Jenna
    Srivastava, Sunil K.
    Whitney, Jon
    Vasanji, Amit
    Reese, Jamie
    Ehlers, Justis
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [36] Ultra-widefield fundus image of an oculocutaneous albinism patient with rhegmatogenous retinal detachment
    Hsin-Pei, L.
    Cherng-Ru, H.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (01):
  • [37] Screening for Hypertension Using Retinal Vascular Calibre in Ultra-Widefield Fundus Imaging
    Robertson, Gavin
    Fleming, Alan
    Williams, Michelle C.
    Trucco, Emanuele
    Quinn, Nicola
    Hogg, Ruth E.
    McKay, Gareth J.
    Pellegrini, Enrico
    Newby, David E.
    van Beek, Edwin J.
    Peto, Tunde
    Dhillon, Baljean
    van Hemert, Jano
    MacGillivray, Tom
    HYPERTENSION, 2018, 72
  • [38] Ultra-widefield fundus autofluorescence patterns in retinitis pigmentosa and other retinal dystrophies
    Trichonas, George
    Traboulsi, Elias I.
    Ehlers, Justis P.
    OPHTHALMIC GENETICS, 2017, 38 (01) : 98 - 100
  • [39] Association between hypertension and retinal vascular features in ultra-widefield fundus imaging
    Robertson, Gavin
    Fleming, Alan
    Williams, Michelle Claire
    Trucco, Emanuele
    Quinn, Nicola
    Hogg, Ruth
    Mckay, Gareth J.
    Kee, Frank
    Young, Ian
    Pellegrini, Enrico
    Newby, David E.
    van Beek, Edwin J. R.
    Peto, Tunde
    Dhillon, Baljean
    van Hemert, Jano
    MacGillivray, Thomas J.
    OPEN HEART, 2020, 7 (01):
  • [40] Clinical Utility of Thresholding Segmentation in Ultra-Widefield (Optos®) Fundus Autofluorescence Images
    MacIver, Sarah
    Sherman, Jerome
    Hutchings, Natalie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)