Optimization analysis of the length of baffles for solar air heaters based on CFD

被引:2
|
作者
Chang, Yuan [1 ,3 ]
Mu, Tian [2 ]
Jia, Binguang [4 ]
机构
[1] Shandong Jianzhu Univ, Sch Architecture & Urban Planning, Jinan, Peoples R China
[2] Shandong Jianzhu Univ, Sch Art, Jinan, Peoples R China
[3] Shandong Management Univ, Sch Art, Jinan, Peoples R China
[4] Shandong Jianzhu Univ, Sch Thermal Engn, Jinan, Peoples R China
关键词
Solar air heaters; collection efficiency; exergy efficiency; economic; pressure loss; THERMAL PERFORMANCE; COLLECTOR; DESIGN;
D O I
10.1080/15567036.2023.2273973
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Incorporating baffles was demonstrably efficacious in augmenting the functionality of solar air heaters (SAHs). A duly validated mathematical model is formulated for SAHs with baffles, aimed at the optimization of baffle length (L-b). Our findings demonstrated that with air velocity (v) spanning from 0.5 to 3.0 m center dot s(-1) and baffle length (L-b) varying between 150 and 750 mm, a discernible rise in pressure loss ensued. This phenomenon is ascribed to the extension of baffles, resulting in escalated air velocity and heightened vortex intensity. In the range of v = 0.5 similar to 3.0 m center dot s(-1), the collection efficiency evinced a marked surge by 4.61% to 11.32% when L-b traversed from 150 to 450 mm, while the collection efficiency tended to be constant as L-b exceeded 450 mm. A holistic evaluation of both pressure loss and heat collection efficiency culminates in the deduction that the pinnacle of operational effectiveness, measuring 60.78%, was attained at Lb = 600 mm and v = 3.0 m center dot s(-1). The economic scrutiny of baffled SAHs unveiled a Coefficient of Useful Energy (Cue) of a mere 0.057y center dot kwh(-1), notably inferior to that resultingensuing from the incineration of fossil fuels under the conditions of v = 3.0 m center dot s(-1) and Lb = 600 mm.
引用
收藏
页码:12405 / 12422
页数:18
相关论文
共 50 条
  • [31] Performance and cost analysis of double flow solar air heaters
    Yousef, Bashria A. A.
    Adam, N. M.
    Leman, A. M.
    PROCEEDINGS OF THE SIXTH IASTED INTERNATIONAL CONFERENCE ON EUROPEAN POWER AND ENERGY SYSTEMS, 2006, : 45 - +
  • [32] Comparative study based on thermal efficiency of solar air heaters
    El Ferouali, Hicham
    Doubabi, Said
    Abdenouri, Naji
    2014 INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2014, : 729 - 734
  • [33] Numerical analysis of mechanical ventilation solar air collector with internal baffles
    Hu, Jianjun
    Sun, Xishan
    Xu, Jinliang
    Li, Zhixian
    ENERGY AND BUILDINGS, 2013, 62 : 230 - 238
  • [34] UNGLAZED SOLAR WALL AIR HEATERS
    HOLLICK, JC
    RENEWABLE ENERGY, 1994, 5 (1-4) : 415 - 421
  • [35] A thermodynamic review of solar air heaters
    Saxena, Abhishek
    Varun
    El-Sebaii, A. A.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 43 : 863 - 890
  • [36] Solar air heaters with external recycle
    Yeh, Ho-Ming
    Ho, Chii-Dong
    APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1694 - 1701
  • [37] Matrix solar air heaters - A review
    Rajarajeswari, K.
    Sreekumar, A.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 57 : 704 - 712
  • [38] THEORY OF BAFFLED SOLAR AIR HEATERS
    YEH, HM
    ENERGY, 1992, 17 (07) : 697 - 702
  • [39] PERFORMANCE STUDIES ON SOLAR AIR HEATERS
    GUPTA, CL
    GARG, HP
    SOLAR ENERGY, 1967, 11 (01) : 25 - &
  • [40] Efficiency of solar plate air heaters
    Samiev M.
    Appl Sol Energy, 2008, 4 (258-261): : 258 - 261