Single-wavelength sO2 measurement based on Gruneisen-relaxation photoacoustic effect

被引:1
|
作者
Wang, Xiatian [1 ,2 ]
Xie, Zhihua [2 ]
Zhang, Jinke [2 ]
Huang, Yusheng [2 ]
Dong, Liquan [1 ,3 ,5 ]
Gong, Xiaojing [2 ,4 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing Key Lab Precis Optoelect Measurement Instr, Beijing, Peoples R China
[2] Chinese Acad Sci, Shenzhen Inst Adv Technol, Res Ctr Biomed Opt & Mol Imaging, Shenzhen Key Lab Mol Imaging,CAS Key Lab Hlth Info, Shenzhen, Peoples R China
[3] Yangtze Delta Reg Acad, Beijing Inst Technol, Jiaxing, Peoples R China
[4] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[5] Beijing Inst Technol, Sch Opt & Photon, Beijing Key Lab Precis Optoelect Measurement Instr, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Gruneisen relaxation; photoacoustic effect; single wavelength; sO(2) measurement; OXYGEN-SATURATION; MICROSCOPY; TOMOGRAPHY; RESOLUTION; BRAIN;
D O I
10.1002/jbio.202300084
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The photoacoustic effect-based sO(2) measurement is attracting more and more attention due to its non-invasiveness and accuracy. Compared with the linear dual-wavelength method, the sO(2) measurement based on single-wavelength excitation can be potentially applied with simplified system construction. However, the single-wavelength methods proposed in previous studies decreases the safety or lacks the in-depth resolution. This paper proposes a novel single-wavelength method based on the Gruneisen-relaxation (GR) nonlinear effects. It avoids the high fluence excitation with maintaining in-depth resolution and obtains the signals in hundreds of nanoseconds, simultaneously improving the safety and detection speed. The construction of a single laser source for GR effect generation makes the system stable. The sO(2) quantification results of blood samples have a good consistency with the reference values. Our work provides a safer and faster measurement method, and a stable system, to promote its application in the clinical area.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effect of Error in SO2 Slant Column Density on the Accuracy of SO2 Transport Flow Rate Estimates Based on GEMS Synthetic Radiances
    Park, Junsung
    Choi, Wonei
    Lee, Hyung-Min
    Park, Rokjin J.
    Kim, Seong-Yeon
    Yu, Jeong-Ah
    Lee, Dong-Won
    Lee, Hanlim
    REMOTE SENSING, 2021, 13 (15)
  • [22] Accurate measurement of volcanic SO2 flux:: Determination of plume transport speed and integrated SO2 concentration with a single device -: art. no. Q02003
    McGonigle, AJS
    Inguaggiato, S
    Aiuppa, A
    Hayes, AR
    Oppenheimer, C
    GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2005, 6
  • [23] The effect of SO2 on the activity of Pd-based catalysts in methane combustion
    R. Burch
    D.J. Crittle
    B.W.L. Southward
    J.A. Sullivan
    Catalysis Letters, 2001, 72 : 153 - 155
  • [24] Effect of SO2 on the oxygen storage capacity of ceria-based catalysts
    Hilaire, S
    Sharma, S
    Gorte, RJ
    Vohs, JM
    Jen, HW
    CATALYSIS LETTERS, 2000, 70 (3-4) : 131 - 135
  • [25] The effect of SO2 on the activity of Pd-based catalysts in methane combustion
    Burch, R
    Crittle, DJ
    Southward, BWL
    Sullivan, JA
    CATALYSIS LETTERS, 2001, 72 (3-4) : 153 - 155
  • [26] Effect of SO2 on the oxygen storage capacity of ceria-based catalysts
    S. Hilaire
    S. Sharma
    R.J. Gorte
    J.M. Vohs
    H.-W. Jen
    Catalysis Letters, 2000, 70 : 131 - 135
  • [27] Cantilever enhanced based photoacoustic detection of SF6 decomposition component SO2 using UV LED
    Chen, Tunan
    Ma, Fengxiang
    Zhao, Yue
    Liao, Zhenghai
    Qiu, Zongjia
    Zhang, Guoqiang
    SENSOR REVIEW, 2022, 42 (01) : 70 - 75
  • [28] Dynamic detection of ppb-level SO2 based on a differential photoacoustic cell coupled with UV-LED
    Zhao, Xinyu
    Qi, Hongchao
    Xu, Yufu
    Li, Chenxi
    Guo, Min
    Zhao, Jikuan
    Cui, Dongyu
    Chen, Ke
    OPTICS LETTERS, 2023, 48 (17) : 4558 - 4561
  • [29] Trace atmospheric SO2 measurement by multiwavelength curve-fitting and wavelength-optimized dual differential absorption lidar
    Fujii, T
    Fukuchi, T
    Cao, NW
    Nemoto, K
    Takeuchi, N
    APPLIED OPTICS, 2002, 41 (03) : 524 - 531
  • [30] THE TRANSIENT LENSING AND MPI SPECTRA OF SO2 IN THE 3B1-1A1 SINGLE PHOTON WAVELENGTH REGION
    COLSON, SD
    CHEUNG, WY
    GLOWNIA, JH
    RILEY, SJ
    CHEMICAL PHYSICS LETTERS, 1980, 76 (03) : 515 - 519