Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map

被引:2
|
作者
Sedova, Ksenia A. [1 ]
van Dam, Peter M. [2 ]
Sbrollini, Agnese [3 ]
Burattini, Laura [3 ]
Necasova, Lucie [4 ]
Blahova, Marie [4 ]
Bocek, Jan [4 ]
Sramko, Marek [4 ]
Kautzner, Josef [4 ]
机构
[1] Czech Tech Univ, Dept Biomed Technol, Fac Biomed Engn, Sitna Sq 3105, Kladno 27201, Czech Republic
[2] Univ Med Ctr Utrecht, Dept Cardiol, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[3] Univ Politecn Marche, Dept Informat Engn, Via Brecce Bianche 12, I-60131 Ancona, Italy
[4] Inst Clin & Expenmental Med, Dept Cardiol, Videnska 1958-9, Prague 14021 4, Czech Republic
来源
EUROPACE | 2023年 / 25卷 / 02期
关键词
Body surface potential mapping; ECG imaging; Heart failure; Cardiac resynchronization therapy; LV lead positioning; AV delay optimization;
D O I
10.1093/europace/euac159
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The standard deviation of activation time (SDAT) derived from body surface maps (BSMs) has been proposed as an optimal measure of electrical dyssynchrony in patients with cardiac resynchronization therapy (CRT). The goal of this study was two-fold: (i) to compare the values of SDAT in individual CRT patients with reconstructed myocardial metrics of depolarization heterogeneity using an inverse solution algorithm and (ii) to compare SDAT calculated from 96-lead BSM with a clinically easily applicable 12-lead electrocardiogram (ECG). Methods and results Cardiac resynchronization therapy patients with sinus rhythm and left bundle branch block at baseline (n = 19, 58% males, age 60 +/- 11 years, New York Heart Association Classes II and III, QRS 167 +/- 16) were studied using a 96-lead BSM. The activation time (AT) was automatically detected for each ECG lead, and SDAT was calculated using either 96 leads or standard 12 leads. Standard deviation of activation time was assessed in sinus rhythm and during six different pacing modes, including atrial pacing, sequential left or right ventricular, and biventricular pacing. Changes in SDAT calculated both from BSM and from 12-lead ECG corresponded to changes in reconstructed myocardial ATs. A high degree of reliability was found between SDAT values obtained from 12-lead ECG and BSM for different pacing modes, and the intraclass correlation coefficient varied between 0.78 and 0.96 (P < 0.001). Conclusion Standard deviation of activation time measurement from BSM correlated with reconstructed myocardial ATs, supporting its utility in the assessment of electrical dyssynchrony in CRT. Importantly, 12-lead ECG provided similar information as BSM. Further prospective studies are necessary to verify the clinical utility of SDAT from 12-lead ECG in larger patient cohorts, including those with ischaemic cardiomyopathy.
引用
收藏
页码:554 / 560
页数:7
相关论文
共 49 条
  • [21] Machine Learning of 12-lead Qrs Waveform Patterns to Identify Cardiac Resynchronization Therapy Patients With Differential Outcomes
    Feeny, Albert K.
    Rickard, John
    Trulock, Kevin M.
    Patel, Divyang
    Toro, Saleem
    Moennich, Laurie Ann
    Varma, Niraj
    Niebauer, Mark J.
    Gorodeski, Eiran Z.
    Grimm, Richard A.
    Barnard, John
    Madabhushi, Anant
    Chung, Mina K.
    CIRCULATION, 2019, 140
  • [22] Familial sudden cardiac death associated with a terminal QRS abnormality on surface 12-lead electrocardiogram in the index case
    Garg, A
    Finneran, W
    Feld, GK
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (06) : 642 - 647
  • [23] BODY-SURFACE ISOPOTENTIAL MAPS IN OLD INFERIOR MYOCARDIAL-INFARCTION UNDETECTABLE BY 12-LEAD ELECTROCARDIOGRAM
    OSUGI, J
    OHTA, T
    TOYAMA, J
    TAKATSU, F
    NAGAYA, T
    YAMADA, K
    JOURNAL OF ELECTROCARDIOLOGY, 1984, 17 (01) : 55 - 62
  • [24] Comparison of value of leads from body surface maps to 12-lead electrocardiogram for diagnosis of acute myocardial infarction
    Owens, Colum
    McClelland, Anthony
    Walsh, Simon
    Smith, Bernie
    Adgey, Jennifer
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (03): : 257 - 265
  • [25] Supine vs semirecumbent and upright 12-lead electrocardiogram: does change in body position alter the electrocardiographic interpretation for ischemia?
    Baevsky, Robert H.
    Haber, Marc D.
    Blank, Fidela S.
    Smithline, Howard
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2007, 25 (07): : 753 - 756
  • [26] A Web-based Visualization Tool for Transforming the 12-lead ECG into a Body Surface Potential Map
    Bond, R. R.
    Finlay, D. D.
    Nugent, C. D.
    Moore, G.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 285 - 288
  • [27] Time to body surface map acquisition compared with ED 12-lead and right-sided ECG
    Fox, TR
    Burton, JH
    Strout, TD
    Bachman, DT
    Higgins, GL
    Snyder, GE
    Shaps, HJ
    Nelson, M
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2003, 21 (02): : 164 - 165
  • [28] The relationship between, electrical axis by 12-lead electrocardiogram and anatomical axis of the heart by cardiac magnetic resonance in healthy subjects
    Engblom, H
    Foster, JE
    Martin, TN
    Groenning, B
    Pahlm, O
    Dargie, HJ
    Wagner, GS
    Arheden, H
    AMERICAN HEART JOURNAL, 2005, 150 (03) : 507 - 512
  • [29] Changes in electrical dyssynchrony by body surface mapping predict left ventricular remodeling in patients with cardiac resynchronization therapy
    Gage, Ryan M.
    Curtin, Antonia E.
    Burns, Kevin V.
    Ghosh, Subham
    Gillberg, Jeffrey M.
    Bank, Alan J.
    HEART RHYTHM, 2017, 14 (03) : 392 - 399
  • [30] Body surface mapping vs 12-lead electrocardiography to detect ST-elevation myocardial infarction
    Ornato, Joseph P.
    Menown, Ian B. A.
    Peberdy, Mary Ann
    Kontos, Michael C.
    Riddell, John W.
    Higgins, George L., III
    Maynard, Suzanne J.
    Adgey, Jennifer
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2009, 27 (07): : 779 - 784