Experimental study on the influence of electrical conductivity of hygroscopic compounds on the performance of a hygroscopic cycle

被引:1
|
作者
Rubio-Serrano, Francisco J. [1 ]
Martinez-Perez, Roberto [2 ]
Meana-Fernandez, Andres [2 ]
Gonzalez-Caballin, Juan M. [2 ]
Gutierrez-Trashorras, Antonio J. [2 ]
机构
[1] IMASA Technol, IMATECH, SLU C Carpinteros 12, Villaviciosa De Odon Ma 28670, Spain
[2] Univ Oviedo, Dept Energy, Thermal Machines & Engines Area, C Wifredo Ricart S-N, Gijon Asturias 33204, Spain
关键词
Electrical conductivity; Rankine cycle; Concentration cycles; Hygroscopic cycle; Steam absorber; Boiler blowdown; REVERSE-OSMOSIS; CORROSION; TEMPERATURE;
D O I
10.1016/j.applthermaleng.2023.121181
中图分类号
O414.1 [热力学];
学科分类号
摘要
Dry climate conditions and the risk of desertification have increased significantly due to the effects of climate change. This fact, combined with the growing energy demand, leads to the need of research focused on improving the performance and efficiency of power plants. In the Hygroscopic Cycle Technology, recently implemented at industrial scale, steam condensation is performed in an absorber using solutions of hygroscopic compounds in water. Hygroscopic effects increase the condensing temperature for a given pressure, allowing the implementation of dry coolers at high ambient temperatures and eliminating cooling water consumption. In this work, due to their relevance in the cycle performance and control, the influence of the concentration of hygroscopic salts in the cycle has been studied, providing insight into proper operational ranges and key parameters. An experimental study of the influence of make-up water quality, with the concentration of impurities measured by water electrical conductivity and cycle mass flow ratio values has been performed in a pilot plant. The results, used to validate a mass and species conservation model, have allowed to obtain operational charts of the cycle and may help to reduce the amount of instrumentation required for cycle control. It was found that the decrease in electrical conductivities with boiler blowdowns in the cycle stabilized at a boiler blowdown ratio of 5%. Blowdown ratios above 10% did not result in substantially lower boiler Cycles Of Concentration in comparison with the increase of thermal energy losses and pumping power (0.42 kJ/kg for each additional 1% of blowdown). It was also found that the ratio between the cooling reflux and turbine steam conductivity had to be higher than 1.1 for condensation by absorption to occur, and that a minimum blowdown ratio of 0.04% was required to avoid using a droplet separator to control live steam quality. Hence, a compromise in the boiler blowdown ratio must be found for each particular application. Finally, hygroscopic effects in condensing pressure and temperature have been experimentally verified at pilot plant scale, leading to potentially higher cycle power output values and higher temperatures in the cooling stream of industrial power cycles, which may make it easier to reject heat from the cycle.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Experimental observations of hygroscopic fine mode particle deposition on electronic circuits and resulting degradation in the performance of contaminated circuits
    Litvak, A
    Gadgil, AJ
    Fisk, WJ
    ACTES DU 14E CONGRES FRANCAIS SUR LES AEROSOLS CFA 98, 1998, : 183 - 188
  • [32] Comparative study of energy performance and water savings between hygroscopic and rankine cycle in a nuclear power plant. Case study of the HTR-10 reactor
    Martinez-Perez, Roberto
    Rios-Fernandez, Juan Carlos
    Cuervo, Guillermo Laine
    Perez, Fernando Soto
    Rubio-Serrano, Francisco J.
    Gutierrez-Transhorras, Antonio J.
    RESULTS IN ENGINEERING, 2023, 20
  • [33] Theoretical and experimental study on natural vibration and Snap-Through of piezoelectric bistable asymmetric laminated composite cantilever plates under hygroscopic influence
    Jiang, Y. D.
    Zhang, W.
    Zhang, Y. F.
    Guo, X. T.
    Amer, A.
    COMPOSITE STRUCTURES, 2025, 358
  • [34] RETRACTION: Experimental and a dual-scale analysis of the influence of coating on humidity control ability of hygroscopic materials with different porosity
    Shi, Xing
    Gong, Guangcai
    Fang, Xi
    Wang, Yuxin
    Huang, Yuting
    An, Jinlin
    Wang, Hongshun
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 461
  • [35] Closure to "Experimental and a dual-scale analysis of the influence of coating on humidity control ability of hygroscopic materials with different porosity"
    Shi, Xing
    Gong, Guangcai
    Fang, Xi
    Wang, Yuxin
    Huang, Yuting
    An, Jinlin
    Wang, Hongshun
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 442
  • [36] Experimental study and finite element analysis on hygroscopic aging of adhesively bonded composite repaired metallic structures with cracks
    Wang Y.
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2020, 42 (04): : 64 - 70
  • [37] Discussion of "Experimental and a dual-scale analysis of the influence of coating on humidity control ability of hygroscopic materials with different porosity"
    Janssen, Hans
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 442
  • [38] A comparative experimental study of the hygroscopic and mechanical behaviors of electrospun nanofiber membranes and solution-cast films of polybenzimidazole
    Zholobko, Oksana
    Wu, Xiang-Fa
    Zhou, Zhengping
    Aulich, Ted
    Thakare, Jivan
    Hurley, John
    JOURNAL OF APPLIED POLYMER SCIENCE, 2020, 137 (39)
  • [39] Experimental Method to Measure High-Temperature Hygroscopic Swelling in Epoxy Mold Compounds and Dielectric Build-Up Films
    Chin, Ian
    Loh, Wei Keat
    Kee, Seow Chien
    He, Yi
    Abdullah, Mohd. Zulkifly
    Tsuriya, Masahiro
    JOURNAL OF ELECTRONIC PACKAGING, 2025, 147 (01)
  • [40] Electrical Conductivity Influence on Eddy-Current Losses: Analytical Study and Experimental Validation
    Plait, Antony
    Dubas, Frederic
    2021 24TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2021), 2021, : 554 - 557