Detection of Babesia bovis using loop-mediated isothermal amplification (LAMP) with improved thermostability, sensitivity and alternative visualization methods

被引:3
|
作者
Arnuphapprasert, Apinya [1 ,2 ]
Nugraheni, Yudhi Ratna [1 ,2 ,4 ]
Aung, Aung [1 ,3 ]
Asada, Masahito [5 ]
Kaewthamasorn, Morakot [1 ]
机构
[1] Chulalongkorn Univ, Fac Vet Sci, Dept Pathol, Vet Parasitol Res Unit, Bangkok, Thailand
[2] Chulalongkorn Univ, Fac Vet Sci, Vet Pathobiol Grad Program, Bangkok, Thailand
[3] Chulalongkorn Univ, Fac Vet Sci, Int Grad Program Vet Sci & Technol VST, Bangkok, Thailand
[4] Univ Gadjah Mada, Fac Vet Med, Dept Parasitol, Yogyakarta, Indonesia
[5] Obihiro Univ Agr & Vet Med, Natl Res Ctr Protozoan Dis, Obihiro, Japan
关键词
INFECTION; DNA; IDENTIFICATION; BIGEMINA; CATTLE; PCR;
D O I
10.1038/s41598-023-29066-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Bovine babesiosis is one of the most economically important tick-borne diseases in tropical and subtropical countries. A conventional microscopic diagnosis is typically used because it is inexpensive and expeditious. However, it is highly dependent on well-trained microscopists and tends to be incapable of detecting subpatent and chronic infections. Here, we developed a novel nucleic acid-based amplification method using loop-mediated isothermal amplification (LAMP) in conjunction with a colori-fluorometric dual indicator for the rapid and accurate detection of Babesia bovis based on the mitochondrial cytochrome b gene. We aimed to improve the thermostability, sensitivity, specificity, and alternative visualization of LAMP-based methods. We assessed its diagnostic performance compared to two conventional PCR agarose gel electrophoresis (PCR-AGE) methods. The thermostability of LAMP reaction mixtures and DNA templates in variable conditions was also assessed. In addition, we evaluated alternative visualization methods using different light sources including neon, LED, and UV lights. We found that the LAMP-neon was ten times more sensitive than the PCR-AGE, while the LAMP-LED and LAMP-UV were 1,000 times more sensitive. The current LAMP method showed no cross-amplification with uninfected cattle DNA or other common blood parasites in cattle, including Babesia bigemina, Theileria orientalis, Anaplasma marginale, and Trypanosoma evansi. In addition, the developed LAMP method has good thermostability and the potential for on-site utility as B. bovis DNA could still be detected up to 72 h after initial preparation. Our findings suggested that the developed LAMP method provides an alternative approach for B. bovis detection with sensitivity higher than PCR-AGE diagnostics, high specificity, and the flexibility to use neon, LED, and UV light sources for positive signal observations.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Detection of Babesia bovis using loop-mediated isothermal amplification (LAMP) with improved thermostability, sensitivity and alternative visualization methods
    Apinya Arnuphapprasert
    Yudhi Ratna Nugraheni
    Aung Aung
    Masahito Asada
    Morakot Kaewthamasorn
    Scientific Reports, 13
  • [2] An improved loop-mediated isothermal amplification assay for the detection of Mycoplasma bovis
    Higa, Yumiko
    Uemura, Ryoko
    Yamazaki, Wataru
    Goto, Shinya
    Goto, Yoshitaka
    Sueyoshi, Masuo
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2016, 78 (08): : 1343 - 1346
  • [3] Development and standardization of a Loop-mediated isothermal amplification (LAMP) test for the detection of Babesia bigemina
    Lizarazo-Zuluaga, Andrea P.
    Carvajal-Gamez, Bertha I.
    Wilkowsky, Silvina
    Cravero, Silvio
    Trangoni, Marcos
    Mosqueda, Juan
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [4] Development of loop-mediated isothermal amplification (LAMP) for detection of Babesia gibsoni infection in dogs
    Mandal, Mrityunjay
    Banerjee, Partha S.
    Kumar, Saroj
    Ram, Hira
    Garg, Rajat
    Pawde, Abhijit M.
    VETERINARY PARASITOLOGY, 2015, 209 (1-2) : 50 - 55
  • [5] Development of a loop-mediated isothermal amplification (LAMP) method for specific detection of Mycobacterium bovis
    Kapalamula, Thoko Flav
    Thapa, Jeewan
    Akapelwa, Mwangala Lonah
    Hayashida, Kyoko
    Gordon, Stephen V.
    Hang' Ombe, Bernard Mudenda
    Munyeme, Musso
    Solo, Eddie Samuneti
    Bwalya, Precious
    Nyenje, Mirriam Ethel
    Tamaru, Aki
    Suzuki, Yasuhiko
    Nakajima, Chie
    PLOS NEGLECTED TROPICAL DISEASES, 2021, 15 (01): : 1 - 15
  • [6] Detection of Kudoa amamiensis Using Loop-Mediated Isothermal Amplification (LAMP)
    Sakai, Masahiro
    Biswas, Gouranga
    Kono, Tomoya
    Hikima, Jun-ichi
    Yokoyama, Hiroshi
    FISH PATHOLOGY, 2015, 50 (03): : 119 - 122
  • [7] Molecular detection of Coxiella burnetii using an alternative loop-mediated isothermal amplification assay (LAMP)
    Raele, Donato Antonio
    Garofolo, Giuliano
    Galante, Domenico
    Cafiero, Maria Assunta
    VETERINARIA ITALIANA, 2015, 51 (01) : 73 - 78
  • [8] Rapid and sensitive detection of Babesia bovis and Babesia bigemina by loop-mediated isothermal amplification combined with a lateral flow dipstick
    Yang, Yimin
    Li, Qun
    Wang, Suhua
    Chen, Xueqiu
    Du, Aifang
    VETERINARY PARASITOLOGY, 2016, 219 : 71 - 76
  • [9] Loop-Mediated Isothermal Amplification (LAMP) for the Detection of Salmonella in Food
    P. A. Kokkinos
    P. G. Ziros
    M. Bellou
    A. Vantarakis
    Food Analytical Methods, 2014, 7 : 512 - 526
  • [10] Detection of phytoplasma by loop-mediated isothermal amplification of DNA (LAMP)
    Obura, E.
    Masiga, D.
    Wachira, F.
    Gurja, B.
    Khan, Z. R.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 84 (02) : 312 - 316