Proportional-Integral-Derivative Controller Based-Artificial Rabbits Algorithm for Load Frequency Control in Multi-Area Power Systems

被引:27
|
作者
El-Sehiemy, Ragab [1 ]
Shaheen, Abdullah [2 ]
Ginidi, Ahmed [2 ]
Al-Gahtani, Saad F. [3 ]
机构
[1] Kafrelsheikh Univ, Fac Engn, Dept Elect Engn, Kafrelsheikh 33516, Egypt
[2] Suez Univ, Fac Engn, Dept Elect Power Engn, Suez 43533, Egypt
[3] King Khalid Univ, Fac Engn, Dept Elect Power Engn, Abha 61421, Saudi Arabia
关键词
artificial rabbits algorithm; proportional-integral-derivative controller; load frequency control; AUTOMATIC-GENERATION CONTROL; CLASSICAL CONTROLLERS; PID CONTROLLER; DESIGN; AGC; OPTIMIZER;
D O I
10.3390/fractalfract7010097
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
A major problem in power systems is achieving a match between the load demand and generation demand, where security, dependability, and quality are critical factors that need to be provided to power producers. This paper proposes a proportional-integral-derivative (PID) controller that is optimally designed using a novel artificial rabbits algorithm (ARA) for load frequency control (LFC) in multi-area power systems (MAPSs) of two-area non-reheat thermal systems. The PID controller incorporates a filter with such a derivative coefficient to reduce the effects of the accompanied noise. In this regard, single objective function is assessed based on time-domain simulation to minimize the integral time-multiplied absolute error (ITAE). The proposed ARA adjusts the PID settings to their best potential considering three dissimilar test cases with different sets of disturbances, and the results from the designed PID controller based on the ARA are compared with various published techniques, including particle swarm optimization (PSO), differential evolution (DE), JAYA optimizer, and self-adaptive multi-population elitist (SAMPE) JAYA. The comparisons show that the PID controller's design, which is based on the ARA, handles the load frequency regulation in MAPSs for the ITAE minimizations with significant effectiveness and success where the statistical analysis confirms its superiority. Considering the load change in area 1, the proposed ARA can acquire significant percentage improvements in the ITAE values of 1.949%, 3.455%, 2.077% and 1.949%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA. Considering the load change in area 2, the proposed ARA can acquire significant percentage improvements in the ITAE values of 7.587%, 8.038%, 3.322% and 2.066%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA. Considering simultaneous load changes in areas 1 and 2, the proposed ARA can acquire significant improvements in the ITAE values of 60.89%, 38.13%, 55.29% and 17.97%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] PI sliding mode load frequency control of multi-area power systems
    Meng, X.P.
    Xue, C.F.
    Zhang, H.G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2001, 21 (03): : 6 - 11
  • [32] A Novel Fuzzy Logic Based Load Frequency Control for Multi-Area Interconnected Power Systems
    Diem-Vuong Doan
    Khoat Nguyen
    Quang-Vinh Thai
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2021, 11 (04) : 7522 - 7530
  • [33] Optimal Design of PID Controller Based Sampe-Jaya Algorithm for Load Frequency Control of Linear and Nonlinear Multi-Area Thermal Power Systems
    El Ela, Adel A. Abou
    El-Sehiemy, Ragab A.
    Shaheen, Abdullah M.
    Diab, Abd El Galil
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2020, 50 : 79 - 93
  • [34] Load Frequency Control of Multi-area Power Systems under Deception Attacks
    Liu, Xinghua
    Bai, Dandan
    Jiang, Rui
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 3851 - 3856
  • [35] Decentralized load frequency controller for a multi-area interconnected power system
    Alrifai, Muthana T.
    Hassan, Mohamed F.
    Zribi, Mohamed
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (02) : 198 - 209
  • [36] A human attitude solving algorithm based on fuzzy proportional-integral-derivative controller and complementary filter
    Wang Y.
    Yang Y.
    Zhang P.
    Zhang X.
    Instrumentation Mesure Metrologie, 2019, 18 (06): : 547 - 552
  • [37] MODEL PREDICTIVE CONTROL (MPC) AND PROPORTIONAL-INTEGRAL-DERIVATIVE (PID) CONTROLLERS FOR LOAD FREQUENCY CONTROL SCHEME
    Singh, Akhilesh
    Kumar, Nagendra
    Badoni, Manoj
    Kumar, Rajeev
    Joshi, Bhagawati Prasad
    Semwal, Sunil
    SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY, 2025, 32 (01):
  • [38] Quasi oppositional harmony search algorithm based controller tuning for load frequency control of multi-source multi-area power system
    Shankar, G.
    Mukherjee, V.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 75 : 289 - 302
  • [39] Bird Swarm Algorithm Optimized TIDD Controller for Multi-area Load Frequency Control Application
    Bhagat S.K.
    Behera S.
    Saha A.
    Bal T.
    Chiranjeevi T.
    Devarapalli R.
    Babu N.R.
    SN Computer Science, 4 (2)
  • [40] Linear programming-based proportional-integral-derivative control of positive systems
    Zhou, Xiaoyue
    Zhang, Junfeng
    Jia, Xianglei
    Wu, Di
    IET CONTROL THEORY AND APPLICATIONS, 2023, 17 (10): : 1342 - 1353