Proportional-Integral-Derivative Controller Based-Artificial Rabbits Algorithm for Load Frequency Control in Multi-Area Power Systems

被引:27
|
作者
El-Sehiemy, Ragab [1 ]
Shaheen, Abdullah [2 ]
Ginidi, Ahmed [2 ]
Al-Gahtani, Saad F. [3 ]
机构
[1] Kafrelsheikh Univ, Fac Engn, Dept Elect Engn, Kafrelsheikh 33516, Egypt
[2] Suez Univ, Fac Engn, Dept Elect Power Engn, Suez 43533, Egypt
[3] King Khalid Univ, Fac Engn, Dept Elect Power Engn, Abha 61421, Saudi Arabia
关键词
artificial rabbits algorithm; proportional-integral-derivative controller; load frequency control; AUTOMATIC-GENERATION CONTROL; CLASSICAL CONTROLLERS; PID CONTROLLER; DESIGN; AGC; OPTIMIZER;
D O I
10.3390/fractalfract7010097
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
A major problem in power systems is achieving a match between the load demand and generation demand, where security, dependability, and quality are critical factors that need to be provided to power producers. This paper proposes a proportional-integral-derivative (PID) controller that is optimally designed using a novel artificial rabbits algorithm (ARA) for load frequency control (LFC) in multi-area power systems (MAPSs) of two-area non-reheat thermal systems. The PID controller incorporates a filter with such a derivative coefficient to reduce the effects of the accompanied noise. In this regard, single objective function is assessed based on time-domain simulation to minimize the integral time-multiplied absolute error (ITAE). The proposed ARA adjusts the PID settings to their best potential considering three dissimilar test cases with different sets of disturbances, and the results from the designed PID controller based on the ARA are compared with various published techniques, including particle swarm optimization (PSO), differential evolution (DE), JAYA optimizer, and self-adaptive multi-population elitist (SAMPE) JAYA. The comparisons show that the PID controller's design, which is based on the ARA, handles the load frequency regulation in MAPSs for the ITAE minimizations with significant effectiveness and success where the statistical analysis confirms its superiority. Considering the load change in area 1, the proposed ARA can acquire significant percentage improvements in the ITAE values of 1.949%, 3.455%, 2.077% and 1.949%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA. Considering the load change in area 2, the proposed ARA can acquire significant percentage improvements in the ITAE values of 7.587%, 8.038%, 3.322% and 2.066%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA. Considering simultaneous load changes in areas 1 and 2, the proposed ARA can acquire significant improvements in the ITAE values of 60.89%, 38.13%, 55.29% and 17.97%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Design of a Proportional-Integral-Derivative Controller for an Automatic Generation Control of Multi-area Power Thermal Systems Using Firefly Algorithm
    K.Jagatheesan
    B.Anand
    Sourav Samanta
    Nilanjan Dey
    Amira S.Ashour
    Valentina E.Balas
    IEEE/CAAJournalofAutomaticaSinica, 2019, 6 (02) : 503 - 515
  • [2] Design of a Proportional-Integral-Derivative Controller for an Automatic Generation Control of Multi-area Power Thermal Systems Using Firefly Algorithm
    Jagatheesan, K.
    Anand, B.
    Samanta, Sourav
    Dey, Nilanjan
    Ashour, Amira S.
    Balas, Valentina E.
    IEEE-CAA JOURNAL OF AUTOMATICA SINICA, 2019, 6 (02) : 503 - 515
  • [3] Pelican Optimization Algorithm-Based Proportional-Integral-Derivative Controller for Superior Frequency Regulation in Interconnected Multi-Area Power Generating System
    Sagor, Abidur Rahman
    Abu Talha, Md
    Ahmad, Shameem
    Ahmed, Tofael
    Alam, Mohammad Rafiqul
    Hazari, Md. Rifat
    Shafiullah, G. M.
    ENERGIES, 2024, 17 (13)
  • [4] Design and analysis of tilt integral derivative controller with filter for load frequency control of multi-area interconnected power systems
    Sahu, Rabindra Kumar
    Panda, Sidhartha
    Biswal, Ashutosh
    Sekhar, G. T. Chandra
    ISA TRANSACTIONS, 2016, 61 : 251 - 264
  • [5] Problems of modelling Proportional-Integral-Derivative controller in automated control systems
    Doroshenko, Anna
    21ST INNOVATIVE MANUFACTURING ENGINEERING & ENERGY INTERNATIONAL CONFERENCE - IMANE&E 2017, 2017, 112
  • [6] Analysis of tilt integral derivative controller-based automatic load frequency control of multi-area multi-source system
    Boddepalli M.K.
    Navuri P.K.
    International Journal of Power Electronics, 2022, 15 (3-4) : 418 - 442
  • [7] Distributed Load Frequency Control for Multi-Area Power Systems
    Wang, Lei
    Wang, Chuan
    Wang, Kun
    Wang, He
    Liu, Zhaoyu
    Yu, Wenwu
    2019 TENTH INTERNATIONAL CONFERENCE ON INTELLIGENT CONTROL AND INFORMATION PROCESSING (ICICIP), 2019, : 100 - 105
  • [8] Dynamic memory event-triggered proportional-integral-based H∞ load frequency control for multi-area wind power systems
    Li, Baihua
    Hu, Shaoyu
    Zhong, Qishui
    Shi, Kaibo
    Zhong, Shouming
    APPLIED MATHEMATICS AND COMPUTATION, 2023, 453
  • [9] Design an optimal fuzzy fractional proportional integral derivative controller with derivative filter for load frequency control in power systems
    Gheisarnejad, Meysam
    Khooban, Mohammad Hassan
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (09) : 2563 - 2581
  • [10] An Optimal Controller for Load Frequency Control in Multi-Area Deregulated power system
    Sina, Alireza
    Kaur, Damanjeet
    JOURNAL OF ELECTRICAL SYSTEMS, 2019, 15 (01) : 142 - 158