A study on the control indices and emission limits of substation noise

被引:3
|
作者
Di, Guoqing [1 ]
Jiang, Haojie [1 ]
Chen, Cong [1 ]
Ma, Jiangang [2 ]
Wu, Jian [2 ]
机构
[1] Zhejiang Univ, Coll Environm & Resource Sci, Hangzhou 310058, Peoples R China
[2] State Grid Shaanxi Elect Power Co, Elect Power Res Inst, Xian 710100, Peoples R China
关键词
Substation noise; Control indices; Emission limits; Mean noise annoyance; Low-frequency noise rating number ( LFNR ); LOW-FREQUENCY NOISE; CRITERION;
D O I
10.1016/j.apacoust.2023.109275
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Equivalent continuous A-weighted sound pressure level (LAeq) underestimates the influence of low-frequency components of substation noise, so it is necessary to optimise control indices and emission limits of substation noise. To this end, 148 noise samples from 110 kV-1000 kV substations were selected. 280 subjects were randomly recruited for listening tests in which the 11-point numerical scale specified by ISO 15666-2021 was used. The mean noise annoyance (Am) of each noise sample was obtained to establish the LAeq-Am model of substation noise. Meanwhile, the LAeq-LFNR model was estab-lished based on the low-frequency noise rating number (LFNR) proposed by Broner. Based on these mod -els, the LFNR corresponding to the limit of LAeq could be determined. The limit of sound pressure level of substation noise was proposed at each 1/1 octave band from 31.5 Hz to 500 Hz and the limit-exceeding ratio for the existing substations noise of China was analyzed. Results showed that Am of 500 kV-1000 kV substation noise was 1.0 higher than that of 110 kV-220 kV substation noise on average when LAeq was 25 dBA-80 dBA. LAeq of the latter were 6.1 dBA higher than that of the former on average when Am was 1- 10. It was estimated that utmost 20 % of substations need further to take noise control measures in order to meet the limit suggested by this study in China. Binding with the limit of LAeq, the limit of sound pres-sure level at each octave band proposed according to equal noise annoyance can better evaluate the influ-ence of substation noise.(c) 2023 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] The noise situation in cement plants and limits for sound emission and sound immission - (Part 1)
    Dupuis, B
    ZKG INTERNATIONAL, 2003, 56 (12): : 52 - 61
  • [42] The noise situation in cement plants and limits for sound emission and sound immission (part 2)
    Dupuis, B
    ZKG INTERNATIONAL, 2004, 57 (01): : 41 - 47
  • [43] A STUDY OF NOISE EMISSION FOR TOOL FAILURE PREDICTION
    LEE, LC
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 1986, 26 (02): : 205 - 215
  • [44] 2D Contour Output Study for Substation Ambient Noise based on the Surfer
    Yu, YiFan
    Xu, Lin
    Zhang, Jian
    ADVANCED BUILDING MATERIALS AND STRUCTURAL ENGINEERING, 2012, 461 : 457 - 460
  • [45] Effects of noise and actuator limits on active control of rotating stall and surge
    Wang, Y
    Murray, RM
    PROCEEDINGS OF THE 37TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-4, 1998, : 4602 - 4607
  • [46] Effects of noise, magnitude saturation, and rate limits on rotating stall control
    Wang, Y
    Murray, RM
    PROCEEDINGS OF THE 36TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-5, 1997, : 4682 - 4688
  • [47] Physical limits on the performance of active noise control through open windows
    Lam, Bhan
    Elliott, Stephen
    Cheer, Jordan
    Gan, Woon-Seng
    APPLIED ACOUSTICS, 2018, 137 : 9 - 17
  • [48] A STUDY OF PARABOLIC CONTROL LIMITS FOR THE EWMA CONTROL CHART
    DAVIS, RE
    WOODALL, WH
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 1994, 23 (01) : 17 - 26
  • [49] The Study of Diesel Noise Control
    Li Houyu
    Jia Qian
    Zhang Guirong
    2012 WORLD AUTOMATION CONGRESS (WAC), 2012,
  • [50] Integration of substation control system
    Semenov, V.A.
    Energetik, 1992, (03):